Omega Vehicle Security DRF-POT, DRF-RES Series manual Instalation, Recommended Fuses

Page 10

User’s Manual DRF Series

CAUTIONS, WARNINGS AND NOTES

INSTALATION

PRECAUTIONS.- The installation and the

future use of this unit must be done by qualified

personnel. The unit has not AC (mains) switch, neither internal protection fuse. It will be in

operation as soon as power is connected.

The installation must incorporate an external mains switch with a protection

fuse and also the necessary devices to protect the operator and the process when using the unit to a control machine or process where injury to personnel or damage to equipment or process may occur as a result of failure of the unit.

RECOMMENDED FUSES

24 Vdc

230 Vac

115 Vac

250mA

70 mA 100 mA

All fuses .-Time Lag Fuse

 

SAFETY PRESCRIPTIONS.- The unit has been designed and tested

under EN-61010-1 rules and is delivered in good conditions. This User’s Ma- nual contains useful information the user

has to respect in order to warrant a proper function of the unit, and good security

conditions. The unit is designed for internal applications, with good ventilation to avoid excessive heating. It can occasionally be applied to temperatures down to 10ºC or up to 70ºC

without security degradation. Do all connections before applying power to the

unit. Do not make wiring changes until power is disconnected from the unit.

Install the unit far from elements generating electric noise, or magnetic

fields, such as power relays, electrical

engines, speed regulators, etc. Do not use until installation is completed.

POWER SUPPLY.- The power supply must be connected to the adequate terminals 1, 2 and 3. The characteristics of the power supply are shown on the side label. Please make sure that the unit is correctly connected to a power supply of the correct

voltage and frequency. Do not connect the unit to lines which are overloaded or which

provide power to systems working on ON- OFF cycles or inductive loads.

ATTENTION : If the power supply is DC voltage, be careful with the polarity indicated for each terminal.

SIGNAL WIRING .- Certain considerations must be given when installing the signal input wires. If the wires are long, they can act as an antenna introducing electrical noise into the unit. Therefore :

Do not install the signal input wires in the same conduit with power lines, heaters,

solenoids, SCR controls, etc ... and always far from these elements.

When shielded wires are used, leave unconnected the shield on the transmitter

side and conect the other end of the shield to the ground terminal of the machine.

EXCITATION VOLTAGE.- Model DRF-PR incorporates an internal power supply for transducers. The output of this power supply is connected to terminals 7 and 9. Do not connect these terminals to an

external power supply, beacuse both units will be permantently damaged.

Page 10

Image 10
Contents User’s Guide Servicing North America Do not use systems with Safetyconsiderations PRESCRIPTION.- Before starting anyIncaseoffire Vaporized liquidsGeneralinformation Power Supply Connections QuickguideSelection Jumpers Input Signal Range Signal AdjustmentSelection Jumpers Output Signal Range AdjustmentExampleformodelDRF-POTSelection Jumpers I Nput Signal Range Dimensions and Connections Mechanicaldimensions Materials Power SupplyGeneralspecifications RangesInstalation Recommended FusesWARRANTY/ Disclaimer Shop online at omega.com