GENERALINFORMATION

The DRF series of Isolated Signal Converters, allow to convert process

signals, temperatures, electrical signals, etc, to current loops or voltage signals for

further retransmision, while introducing

into the system galvanic isolation barriers between the input, the output and the

power supply circuits.

The DRF series of Isolated Signal

Converters, offer an excellent relation between signal conversion speed and

measurement accuracy. Offering up to a

0.2% accuracy and down to 70ms response time, these units can process

information coming from probes or transducers, in such a way that can be

quickly retransmitted in a fast and

accurate form to remote data acquisition systems or PLC’s. The isolated signal

converters of the DRF series are ideal to integrate into 12 bit data acquisition

systems.

Its powerful galvanic isolation of 3500 V introduces high security to the measuring

systems, preventing the propagation of those phenomenon which usually cause

damage, such as transient peaks or energy shocks in any of the circuits of the

system. The galvanic isolation also acts

as a strong CE barrier. The decoupling created between the circuits avoids

pernicious effects on the output, such as ground loops or signal leaks, which distort

the acquired data and are extremely

difficult to isolate once introduced into the signal.

The isolation offered by the DRF series of Isolated Signal Converters is a 3 way

isolation. Thus, all the benefits exposed

above are applicable to any of the three circuits composing the instrument : input,

output and power.

Recalibrationoftheinstrumentsisrealized

in a fast and easy way. Opening the front cover grants access to the configuration

jumpers. Additional Span and Offset potentiometers are directly accessible

fromthefrontalpart.Thesepotentiometers

are highly decoupled, minimizing the iterations needed to obtain a correct

adjustment.

In order to obtain a higher and quickest

benefit of the DRF units, we recommend you to read carefully the information

provided in this manual before proceeding

to the installation of the instrument. In this manual you will find all technical data,

both electrical and mechanical, needed for a correct instalation and utilization.

Note : The DRF Series Isolated Signal Convertershaveacharacteristicslabel attached on the side of the instrument. Check that this information matches with your requirements for the specific application, and especially check the value and type of the Power Supply.

Page 4

Image 4
Contents User’s Guide Servicing North America Safetyconsiderations PRESCRIPTION.- Before starting any IncaseoffireDo not use systems with Vaporized liquidsGeneralinformation Power Supply Connections QuickguideSignal Adjustment Selection Jumpers Output Signal RangeSelection Jumpers Input Signal Range AdjustmentExampleformodelDRF-POTSelection Jumpers I Nput Signal Range Dimensions and Connections Power Supply GeneralspecificationsMechanicaldimensions Materials RangesInstalation Recommended FusesWARRANTY/ Disclaimer Shop online at omega.com