Lochinvar SDT/SET065 - 119 operation manual Maintenance Schedule

Page 21
￿ WARNING
￿ DANGER
￿ WARNING
￿ WARNING

7Maintenance

The Lochinvar SDT/SET series indirect water heater is an extremely simple device and as such requires very little maintenance. There are, however, several items which should be checked out on an annual or as needed basis to ensure a reliable supply of hot water:

*Make sure that the rest of the solar, boiler and domestic water piping is free of leaks.

*If there is an oil lubricated circulator in the system, make sure it is lubricated as called for by the circulator manufacturer.

*Make sure that the boiler is maintained in accordance with the boiler manufacturer’s instructions.

*If a water treatment system is required to keep the water chemistry within the parameters shown in Table 2A (see Section 2 - Pre-Installation), make sure that this system is properly maintained.

Maintenance Schedule

Annual service by a qualified service technician should include the following:

￿Any procedure required by local codes.

￿Verify system pressure. Air venting procedure may require adding water to bring boiler system up to pressure, typically 12 psig.

￿Manually operate T&P relief valve at least once a year. This will release some hot water.

Before operating a T&P relief valve, make sure no one is in front of or around the T&P relief valve discharge piping. Hot discharge water can cause severe personal injury or substantial property damage.

￿Move operating lever to open position for a few seconds and then move it back, allowing it to snap closed. After the T&P relief valve is operated, if it continues to release water, close the cold water inlet to the water heater immediately. Follow the draining instructions, and replace the T&P relief valve. If the T&P relief valve weeps periodically, it may be due to thermal expansion. Do not plug the T&P relief valve or discharge piping.

Plugging the T&P relief valve or discharge piping can cause excessive pressure in the water heater, resulting in severe personal injury, death, or substantial property damage.

￿Follow instructions on circulator to oil, if required.

￿Check mixing valve, valves, pipes, and fittings for leaks.

￿Check function of the field-installed controls and valves. See component manufacturer’s instructions.

￿Review homeowner’s maintenance responsibilities and their frequencies, including any not listed in the following section.

SDT/SET Installation & Operation Manual

Homeowner monthly maintenance to include:

￿Visually check valves, pipes, and fittings for leaks. Call a qualified service technician to repair leaks.

To Fill the Water Heater

1.Close the water heater drain valve by turning the knob clockwise.

2.Open the cold water supply shutoff valve.

3.Open several hot water faucets to allow air to escape from the system.

4.When a steady stream of water flows from the faucets, the water heater is filled. Close the faucets and check for water leaks at the water heater drain valve, combination temperature and pressure relief valve and the hot and cold water connections.

Water from opened drain valves, unions and other connections may be extremely hot. To avoid severe personal injury, death, or substantial property damage:

- Tighten all drain hose connections. - Direct hot water away from all

persons.

To Drain the Water Heater

Should it become necessary to completely drain the water heater, be sure to follow the steps below:

1.Disconnect the power supply to the heat source. Co n s u l t the plumbing professional or electric company in your area for service.

2.Close the cold water supply shutoff valve.

3.Open the drain valve on the water heater.

4.Open a hot water faucet to allow air to enter the system.

Drain the water heater if it will be shut off and exposed to freezing temperatures. Freezing water will expand and damage the water heater.

If boiler water contains sufficient antifreeze, then only the domestic water needs to be drained.

If boiler water does not contain sufficient antifreeze, the boiler water and the domestic water must be drained.

If antifreeze is used in the boiler water, check concentration. Boiler water (including additives) must be practically non-toxic, having a toxicity rating or class of 1, as listed in the “Clinical Toxicology of Commercial Products”. A maximum 50/50 mixture of inhibited propylene glycol is recommended. Follow the antifreeze manufacturer’s instructions.

Do not use automotive, ethylene glycol or petroleum-based antifreeze. Do not use any undiluted antifreeze. This can cause severe personal injury, death, or substantial property damage.

21

Image 21
Contents Installation & Operation Manual Solar Dual Coil TankSave this manual for future reference Contents Please read before proceeding When servicing the indirect water heaterComponent Material General InformationPre-installation Characteristic Min MaxMinimum Clearance to the Element Cover Zone with Circulator to Aquastat Boiler Side Piping SDT modelsMultiple Tank Connections Boiler Side Zone with Valve to AquastatPressure Drop Values SDT / SET119 Friction LossZone #1 2Piping Diagram Zoned with Valves 3Knight Boiler Primary / Secondary Piping 4Multiple Tank Connections Basic Domestic Piping Domestic Side Tank PipingDomestic Water Piping for Distant Fixtures Multiple Tank Domestic Water Piping1Drain Valve Installed Install Drain ValveRelief Valve Discharge Piping 2Recommended Domestic Water Piping SDT/SET models Thermostat Adjustment WiringElectrical Connection Combination Thermostat and High Limit Control ECOModel Volts / Phase Watts / Amps Breaker Type Wire Gage SET Wiring Single ElementConnect tank sensor Install tank sensor4Wiring for Zone Control Start-up and Check-out Maintenance Schedule MaintenancePerformance Data 180 Boiler200 High Output Piping Series PipingParallel Piping Parallel Configuration Friction Loss SDT Series

SDT/SET065 - 119 specifications

The Lochinvar SDT/SET065 - 119 is a sophisticated heating solution that combines efficiency, reliability, and innovative technology to meet the demands of modern residential and commercial applications. As a participant in the highly competitive heating market, Lochinvar has established a reputation for producing high-quality products, and the SDT/SET065 - 119 is no exception.

One of the main features of the Lochinvar SDT/SET065 - 119 is its high-efficiency operation. With an impressive thermal efficiency rating, this unit minimizes energy consumption while maximizing output. This efficiency not only helps in reducing utility bills for users but also contributes to a more sustainable environment by lowering carbon emissions. The design of the unit incorporates advanced heat exchanger technology that optimizes thermal transfer, ensuring that homeowners and businesses receive the precise heating they require.

The SDT/SET065 - 119 also boasts impressive versatility. It can be configured to work with various hydronic heating systems, making it suitable for a wide range of applications, from radiant floor heating to baseboard heating systems. Additionally, the compact design of the unit allows for easy installation and integration into existing systems, without requiring significant modifications.

User-friendly controls are another highlight of the Lochinvar SDT/SET065 - 119. The unit features advanced digital control technology that allows for easy temperature regulation and monitoring. This technology also enables users to take advantage of multiple operating modes, enhancing both comfort and efficiency. Furthermore, built-in diagnostic capabilities provide real-time feedback on the system’s performance, facilitating easier troubleshooting and maintenance.

Safety is also a key consideration in the design of the SDT/SET065 - 119. The unit includes multiple safety features, such as over-temperature protection and pressure relief systems, ensuring reliable operation without compromising user safety.

In summary, the Lochinvar SDT/SET065 - 119 exemplifies modern heating technology. Its high efficiency, versatility, user-friendly controls, and robust safety features make it an ideal choice for those seeking a reliable and effective heating solution. Whether for residential or commercial use, the Lochinvar SDT/SET065 - 119 stands out as a top-tier option in the heating market.