Lennox International Inc 51M37 Buttons, Backlight, Timers & Settings, Thermostat Buttons

Page 2

Within a few seconds, the Home Screen appears (see fig- ure 2) with default settings as shown. After about 1 minute of initialization time, the actual room temperature will be displayed.

NOTE − Tables 2 and 3 on page 8 show all system and programming defaults.

Thermostat Buttons

Heat

Cool

Prog

Day/Time

Home Screen

MO

AM I2:00

HOLD

FILTER

SERVICE

FAN

AUTO

Fan Hold

 

Settings Enter

(DOOR

OPEN)

Figure 3

ROOM

SYSTEM

70

°

 

HEAT

Figure 2

At this point, the thermostat will be fully functional; its de- fault temperature setpoint (not shown) is 70°F. At this point, if the equipment has been fully powered and if a heat demand were present, the system would begin operating.

NOTE − Temperature scale default is Fahrenheit units but may be reset to show Celsius, if desired. See page 8.

Buttons, Backlight, Timers & Settings

Buttons are located behind the small door on the right− hand side of the thermostat (see figure 3).

IMPORTANT

Do NOT begin pressing buttons until after you read the following section describing each button.

A pale blue display backlight illuminates for 30 seconds each time any button is pressed.

When PROG or DAY/TIME is pressed, a field begins flash- ing, expecting another input. Start making changes within 15 seconds or the HOME screen will return.

When an Arrow, HOLD, HEAT, or COOL button is pressed, SETPOINT and the temperature setting appears for 15 seconds. If desired, start making changes within 15 sec- onds or the HOME screen will return. The backlight will turn off 15 seconds after the HOME screen reappears.

DAY/TIME − Setting the Day and Time

Press the DAY/TIME button and set the CURRENT hour, minute, and day of week as follows:

1.AM12" will flash on the screen. Press the Up/Down ar- rows buttons to change the hour. (or must correspond to time of day.) Press DAY/TIME OR, if ad- justing for daylight savings time, pressing ENTER stores the single change and exits to the HOME screen, bypassing minutes and day of week.

2.Minutes will flash. Use the Up/Down arrow buttons to display the minutes past the hour. Press DAY/TIME.

3.Day

buttons to display the current day. Day selections are abbreviated as

and Y/TIME.

4.The HOME screen reappears; confirm day and time are correct. This completes day and time setting.

Page 2

505050M 5/1/05

Image 2
Contents 51M37 Merit Series Thermostat Buttons Buttons, Backlight, Timers & SettingsDAY/TIME − Setting the Day and Time Home ScreenHeat − Using the Heat Mode FANCool Mode Disabled Cool − Using the Cool ModeEnabling and Disabling Cool Mode Turn Cool ON/OFFI036 FAN PM I036 FANSettings − Filter/Maintenance Reminders FAN − Controlling the Fan OperationThermostat Reset Settings − Balance PointService Indicator Removing/Installing ThermostatDefault Thermostat Settings Technical SpecificationsOver−Temperature Protection Smart Setback Recovery via DIP switch #6Equipment Protection Timers Maintenance ReminderHeating Demands Thermostat Output TableCooling Demands 51M35 Merit Series 51M35 Merit Series Thermostat505049M 5/1/05 Heat/Cool Mode Disabled Heat − Using the Heat Mode Cool − Using the Cool ModeEnabling and Disabling Heat Mode Turn Heat ON/OFFHold − Using Temperature Hold Modes 1st press Removing and Installing Thermostat I0i451M35 Terminal Designations Gas Heat, Continuous Fan Thermostat OutputsGas Heat, Auto Fan Electric Heat, Auto Fan51M34 Merit Series 51M34 Merit Series Thermostat505048M 5/1/05 51M34 Series 5/2 I036 FAN OFF I0i4 51M34 Terminal Designations Heat Demand Cool Demand No Demand 51M39 Merit Series 51M39 Merit Series ThermostatI026 I030 Heat/Cool Mode Disabled Cooling Demand530 Auto − Using the Autochangeover Mode Copy a Programmed Day to An other Day Filter Maintenance Indicators Displaying Outside TemperatureCheck Outside Temperature Service Indicator FlashingDefault Program Settings Time & Temp Autochangeover Deadband Selection via DIP switch #7 Indoor Temperature Measurement RangeOutdoor Temperature Measurement Range 51M39 Terminal DesignationsThermal-mechanical switch opens W1 and W2 at 93F+/−6F Page −Day Programmable Thermostat 51M42 Merit Series51M42 Merit Series Thermostat 505069M 07/05 Large Heat Heating Demand FAN Auto MID Reminder Settings Display Using Fan on I026 Default Program Settings − Time & Temp With Electric Backup no outdoor sensorTechnical Specifications 51M42 Terminal Designations 51M38 Merit Series 51M38 Merit Series ThermostatY/TIME button 51M38 Series 5/2 Hold − Using Temperature Hold Modes Repeat steps a and B for as many days as you Settings Thermostat Output Table 51M38 Terminal Designations

51M37 specifications

Lennox International Inc, a prominent player in the heating, ventilation, and air conditioning (HVAC) market, has made significant strides in innovation and technology in recent years. Among its notable offerings is the Lennox 51M37, a well-engineered component designed to enhance HVAC efficiency and reliability.

The 51M37 is primarily known for its advanced motor technology, incorporating ECM (Electronically Commutated Motor) design, which significantly reduces energy consumption compared to traditional motor systems. This motor type is key to Lennox's commitment to sustainability, as it not only maintains optimal performance but also minimizes the carbon footprint associated with residential and commercial heating and cooling tasks.

A standout feature of the 51M37 is its intelligent control system, which allows for more precise management of airflow and temperature. This technology can adapt to specific environmental conditions and consumption patterns, optimizing performance and providing substantial cost savings on energy bills. The integration of smart technology aligns with modern demands for energy efficiency and control, making the 51M37 a vital component in achieving higher energy ratings for HVAC systems.

In terms of compatibility, the 51M37 is engineered to work seamlessly with a variety of Lennox heating and cooling units, ensuring versatility for both new installations and retrofits. This compatibility enhances system integration, resulting in improved overall performance.

The construction of the 51M37 emphasizes durability and reliability, featuring high-quality materials that withstand the challenges of constant operation. Its robust design is perfect for diverse environments, ensuring that it functions reliably in both residential settings and commercial applications.

Another characteristic worth noting is the user-friendly installation process, allowing HVAC technicians to install the 51M37 with relative ease. This not only reduces labor costs but also ensures that the system can commence operation quickly without extensive downtime.

Overall, Lennox International's 51M37 embodies innovation, efficiency, and reliability in HVAC technology. With its advanced ECM motor, intelligent controls, and durable construction, it stands as a prime example of how modern HVAC solutions can lead to enhanced performance and energy savings. As the industry continues to evolve, products like the 51M37 will play a critical role in shaping the future of heating and cooling, aligning with sustainability goals and meeting the needs of consumers.