HOLD − Using Temperature Hold Modes

PROG − Thermostat Programming

When HOLD is displayed at the HOME screen, the ther- mostat is in a temperature hold condition. This means that the temperature program data is ignored and the thermo- stat functions much like a non−programmable thermostat.

Adjusting Temperature Setpoint in Hold Mode

The temperature setpoint represents the desired tempera- ture of the space around the thermostat. The default tem- perature setpoint in Hold mode is 70°F.

To adjust the setpoint, press the UP or DOWN (YB) arrow buttons (see figure 12); the existing setpoint is displayed to the right of the actual room temperature. Each button press adjusts the setpoint up or down by 1 degree.

Hold Temperature Mode

 

 

 

Heat

Cool

MO

I0:36 FAN

Prog

Day/Time

PM

AM

 

 

 

 

 

 

HOLD AUTO

 

 

ROOM

SYSTEM

 

 

SETPOINT COOL

 

 

72° 68°

Fan

Hold

 

 

 

Settings Enter

Figure 12

After the desired setpoint is reached, the HOME screen will reappear after about 15 seconds.

Permanent Hold Mode

At any time the program is running, from the HOME screen, set a permanent hold (program override) by press- ing the HOLD button (see figure 12). The thermostat now functions much like a non−programmable thermostat. Use the Up/Down arrow buttons to adjust the hold setpoint. To return to the program, press HOLD again.

Temporary (2-Hour) Hold

At any time the program is running, from the HOME screen, set a temporary 2-hour hold by pressing the Up/ Down arrow buttons until the desired setpoint is displayed; flashes (see figure 13). This overrides the pro- gram for 2 hours from the last button press, then returns to the program.

Temporary Hold Temperature Mode

 

 

Heat

Cool

MO

 

Prog

Day/Time

PM I0:36 FAN

AM

 

 

 

PROG B HOLD AUTO

 

 

ROOM

SYSTEM

 

 

SETPOINT COOL

 

 

72° 68°

Fan

Hold

 

 

Settings

Enter

Figure 13

While in Temporary Hold, press HOLD once to switch to Permanent Hold (HOLD displays solid; PROG not dis- played); press HOLD again to return to the program (PROG displays; HOLD not displayed).

The 51M37 thermostat can be programmed to perform a set of either heating or cooling events (but not a combination of heat and cool) for 5 consecutive days using a set of 4 unique events per day. The remaining 2 days can then be set for a different set of 4 unique events per day. Both the consecutive days and the events/temperature are set by the homeowner.

To Change Consecutive Days...

To alter the 5 consecutive days, press and hold the PROG button for 5 seconds. The 5 consecutive day period is then displayed (default is MOnday thru FRiday). To change to a different 5-consecutive days, use the Up/ Down arrow buttons. Any 5 consecutive−day span may be selected, for example, in figure 14, Saturday through Wednesday is defined as the 5−day programming (Thurs- day and Friday would constitute the 2−day programming). Press the PROG button when finished.

Change Consecutive days

MO TU WE TH FR SA SU

FILTER

 

Figure 14

To Set Program Events and Temperatures...

Figure 15 gives an example of how the two sets of pro- grams can be set for a normal workweek and weekend.

In the 5−day bar graph, note how programs A and C reflect the desired warmth while the home IS occupied (72°); B allows less heating while the home is NOT occupied; D re- flects a cooler sleeping temperature. The 2−day bar graph would support day−long occupancy and, because the first program begins later, a less−demanding time schedule.

5/2 Program Example

5−DAY PROGRAM: A

B

C D

72°

68°

64°

6AM NOON 6PM MID 6AM NIGHT

2−DAY PROGRAM:

A B

C

D

72°

68°

64°

6AM NOON 6PM MID 6AM NIGHT

Figure 15

NOTE − Pressing ENTER during the following program- ming steps, saves and exits to the HOME screen.

To program events and temperatures, perform the follow- ing steps, once with Cool selected and once with Heat se- lected.

1.Press and release PROG. AM 6:00", period

the 5 consecutive days are displayed; AM 6" flashes.

2.Use the Up/Down arrow buttons to select the desired hour; press PROG when the desired hour is reached.

3.Use the Up/Down arrow buttons to select the desired minute; press PROG.

4.Use the Up/Down arrow buttons to select the desired temperature setpoint; press PROG.

Page 5

51M37 SERIES 5/2

Image 5
Contents 51M37 Merit Series DAY/TIME − Setting the Day and Time Buttons, Backlight, Timers & SettingsThermostat Buttons Home ScreenFAN Heat − Using the Heat ModeEnabling and Disabling Cool Mode Cool − Using the Cool ModeCool Mode Disabled Turn Cool ON/OFFPM I036 FAN I036 FANFAN − Controlling the Fan Operation Settings − Filter/Maintenance RemindersService Indicator Settings − Balance PointThermostat Reset Removing/Installing ThermostatTechnical Specifications Default Thermostat SettingsEquipment Protection Timers Smart Setback Recovery via DIP switch #6Over−Temperature Protection Maintenance ReminderHeating Demands Thermostat Output TableCooling Demands 51M35 Merit Series Thermostat 51M35 Merit Series505049M 5/1/05 Enabling and Disabling Heat Mode Heat − Using the Heat Mode Cool − Using the Cool ModeHeat/Cool Mode Disabled Turn Heat ON/OFFHold − Using Temperature Hold Modes 1st press I0i4 Removing and Installing Thermostat51M35 Terminal Designations Gas Heat, Auto Fan Thermostat OutputsGas Heat, Continuous Fan Electric Heat, Auto Fan51M34 Merit Series Thermostat 51M34 Merit Series505048M 5/1/05 51M34 Series 5/2 I036 FAN OFF I0i4 51M34 Terminal Designations Heat Demand Cool Demand No Demand 51M39 Merit Series Thermostat 51M39 Merit SeriesI026 I030 Heat/Cool Mode Disabled Cooling Demand530 Auto − Using the Autochangeover Mode Copy a Programmed Day to An other Day Check Outside Temperature Displaying Outside TemperatureFilter Maintenance Indicators Service Indicator FlashingDefault Program Settings Time & Temp Outdoor Temperature Measurement Range Indoor Temperature Measurement RangeAutochangeover Deadband Selection via DIP switch #7 51M39 Terminal DesignationsThermal-mechanical switch opens W1 and W2 at 93F+/−6F Page −Day Programmable Thermostat 51M42 Merit Series51M42 Merit Series Thermostat 505069M 07/05 Large Heat Heating Demand FAN Auto MID Reminder Settings Display Using Fan on I026 With Electric Backup no outdoor sensor Default Program Settings − Time & TempTechnical Specifications 51M42 Terminal Designations 51M38 Merit Series Thermostat 51M38 Merit SeriesY/TIME button 51M38 Series 5/2 Hold − Using Temperature Hold Modes Repeat steps a and B for as many days as you Settings Thermostat Output Table 51M38 Terminal Designations

51M37 specifications

Lennox International Inc, a prominent player in the heating, ventilation, and air conditioning (HVAC) market, has made significant strides in innovation and technology in recent years. Among its notable offerings is the Lennox 51M37, a well-engineered component designed to enhance HVAC efficiency and reliability.

The 51M37 is primarily known for its advanced motor technology, incorporating ECM (Electronically Commutated Motor) design, which significantly reduces energy consumption compared to traditional motor systems. This motor type is key to Lennox's commitment to sustainability, as it not only maintains optimal performance but also minimizes the carbon footprint associated with residential and commercial heating and cooling tasks.

A standout feature of the 51M37 is its intelligent control system, which allows for more precise management of airflow and temperature. This technology can adapt to specific environmental conditions and consumption patterns, optimizing performance and providing substantial cost savings on energy bills. The integration of smart technology aligns with modern demands for energy efficiency and control, making the 51M37 a vital component in achieving higher energy ratings for HVAC systems.

In terms of compatibility, the 51M37 is engineered to work seamlessly with a variety of Lennox heating and cooling units, ensuring versatility for both new installations and retrofits. This compatibility enhances system integration, resulting in improved overall performance.

The construction of the 51M37 emphasizes durability and reliability, featuring high-quality materials that withstand the challenges of constant operation. Its robust design is perfect for diverse environments, ensuring that it functions reliably in both residential settings and commercial applications.

Another characteristic worth noting is the user-friendly installation process, allowing HVAC technicians to install the 51M37 with relative ease. This not only reduces labor costs but also ensures that the system can commence operation quickly without extensive downtime.

Overall, Lennox International's 51M37 embodies innovation, efficiency, and reliability in HVAC technology. With its advanced ECM motor, intelligent controls, and durable construction, it stands as a prime example of how modern HVAC solutions can lead to enhanced performance and energy savings. As the industry continues to evolve, products like the 51M37 will play a critical role in shaping the future of heating and cooling, aligning with sustainability goals and meeting the needs of consumers.