Teka Gas Hobs CGX 60 4G IS Technical data, Common Features for ALL Models with Automatic Ignition

Page 11

GB

Technical data

COMMON FEATURES FOR ALL MODELS WITH AUTOMATIC IGNITION

The supply voltage and frequency will be as shown on the rating plate.

COMMON FEATURES FOR THESE GAS MODELS

Warnings:

a)Before installation, make sure that the local supply conditions (the gas type and pressure) are compatible with the applian- ce's setup.

b)The setup conditions for this appliance are written on the label (or the rating plate).

c)This appliance should not be connected to a device for removing combustion` pro- ducts.

It should be installed and connected in com- pliance with the current installation stan- dards. Special attention should be paid to the regulations applying to ventilation.

The use of a gas cooking appliance produces heat and moisture at the site where it is installed. The kit- chen should be provided with suitable ventilation: natural ventilation sources should be kept clear, a window should be opened or an effective mechanical

Table 3

ventilation system device should be installed (mechanical ventilation hood).

Intense and prolonged use of the appliance require complementary ven- tilation, such as opening a window, or more efficient ventilation, such as increasing the power of the mechanical ventilation, if there is one.

You should keep the Guarantee Certificate or, where relevant, the technical datasheet, together with the Instruction Manual for the duration of the useful life of the appliance. It con- tains important technical information.

Class 3 hob.

Table 2

Country

Category

Spain

II2H3+

Portugal

II2H3+

United Kingdom

II2H3+

Switzerland

II2H3+

Ireland

II2H3+

Chez Republic

II2H3+

Greece

I3+

Hungary

I2H

Denmark

I2H

Norway

I2H

Finland

I2H

Sweden

I2H

Rumania

II2H3B/P

Burner

 

 

 

Triple

Fast

Semi-fast

Auxiliary

 

 

 

ring

Nominal Heat Rate

kW

 

3,5

3

1,75

1

 

G-20 (Nm3/h)

20 (mbar)

0,33

0,29

0,17

0,10

Nominal Rate*

G-30 (Kg/h)

 

29 (mbar)

0,25

0,22

0,13

0,07

 

G-31 (Kg/h)

 

37 (mbar)

0,24

0,21

0,13

0,07

Reduced calorific consumption

Kw

 

1,55

0,77

0,47

0,33

Output

%

 

 

>52

>52

>52

* Rate over Higher Heating Value (Hs )

11

Image 11
Contents CGX 60 4G is CGX 70 5G is TR Índice / Inhalt / Table des matières Information technique InstallationUtilisation et Maintenance PrésentationCGX 70 5G is TR Introduction / Allgemeines / Présentation / ΠαρουσίασηSafety Instructions Guide to Using the Instructions BookletPositioning the hobs GB InstallationFixing the hob Connecting the gasPositioning the oven Gas conversion Connecting the electricityFront view of the gas tap 4G is Is TR GB Technical InformationModels CGX CGX 70 5G Common Features for These GAS Models Technical dataCommon Features for ALL Models with Automatic Ignition Touch control panel user Instructions GB Use and MaintenanceSpecial requirements Before first use Component parts of a gas BurnerRE-LIGHTING Turning on the ApplianceIgniting the Burners Maximum Operation Time Emergency SHUT-OFFTurning OFF the Burner Turning OFF the ApplianceComponent parts of an Automatic control and safety System Using the hob Suggestions for using Burners effectivelyReminder GB Cleaning and care Maintenance Sparks fly occasionally GB If something doesnt workThere is a spark but the burner doesnt light Gas burners do not light