Remote Protocol Setup

This feature is used to set the basic RS-232/RS-485 protocols to control the DVR remotely from a PC.

Pressing ENTER after scrolling to the Remote option will bring up the following menu options:

Remote mode: Selects whether to use an RS-232 or RS-485 interface.

Baud rate: Selects the baud rate (bps) to be used for the connection.

The available settings are: 115200, 57600, 19200, 9600, 3600, 2400, 1200.

ID:Selects a numerical number representing the DVR being controlled if multiple units are being used.

The available setting are: 000 – 255

The remote connection on the DVR uses 8 data bits, 1 start bit, and 1 stop bit, no Parity.

Below is an example of the data stream with the control codes shown.

(Menu) Search Timer Record Alarm

?Remote System Event

ACT – OxFF

OxCO

ID

FUNCTION

STOP – Ox7F

Please refer to Appendix 3 for information on the Pin connections and command protocols that would be used in this application.

Timer Recording Setup

On the Main menu, selecting the Timer option will allow you to set daily schedules in which you would like the DVR to automatically record.

Pressing ENTER after scrolling to the Timer option will bring up the following menu options:

Timer

 

(Timer)

 

Day

Start

End

IPS

Daily

01:00

02:00

Off

SUN

12:00

13:00

Off

MON

08:00

09:00

Off

MO~FR

00:00

01:00

Off

SA~SU

20:00

21:00

Off

JAN-01

15:00

16:00

Off

Timer Enable:

No

 

 

 

 

 

1.Press ? / ? to select the day(s) to record on, the available options are…

Daily: Everyday

SUN: Sunday

MON: Monday

TUE: Tuesday

WED: Wednesday

THU: Thursday

FRI: Friday

SAT: Saturday

MO-FR: Monday to Friday

SA-SU: Saturday & Sunday

JAN-01: Special Date

OFF: Not activated

(Menu) Search

?Timer Record Alarm

Remote

System

Event

13

Image 14
Contents Channel Digital Video Recorder DXR109 L3R 4C1 Canada Table of Contents Important Safety Instructions Features IntroductionSystem Contents Front Panel Controls Slow LED IndicatorsPause / Up Camera SelectBack Panel Connections Accessing the Main Menu Setting the External Audible Alarm device System Set UpSetting the Internal Audible Alarm Buzzer Selecting the Audio Input ChannelSetting the Dwell Time Setting the Motion Audible Alarm featureSetting the Alarm Duration Setting the Message Latch featureJan-01 Mon Changing the System PasswordResetting System to Factory Defaults Clearing the Hard Drive DataRemote Protocol Setup Timer Recording SetupBEST, HIGH, NORMAL, Basic Ntsc 15A, 15, 8, 4, 2 PAL 12A, 12, 6, 3, 2Record IPS Setup Record SettingsHDD Overwrite Setup Record Quality SetupTitle Camera Channel SetupAlarm Polarity DwellMotion Detection Setup Motion DetectionMotion Detection Setup 1~9 2MOTION Detection Setup LinePower Restore HDD ErrorSystem Error HDD WarningOperation Zoom Alarm ListPicture in Picture PIP Video SearchPause Slow reverseImage Jog StopTroubleshooting Problem SolutionTechnical Specifications YY/NN/DD, DD/MM/YY, MM/DD/YY, OFFRemove the Cartridge Casing from the DXR109 Appendix 1 Installing the HDDCartridge Casing Lock the Cartridge Secure the HDD in the cartridge casingSlide the top Cover over the Cartridge Casing Appendix 2 Connection Diagram to Cameras and Monitor Appendix 3 Pin Configurations Pin References for RS-232 / Alarm Block Appendix 4 Rack Mount Installation Appendix 5 Recording Times in Hours Ntsc SystemAppendix 6 RS232 Remote Protocol Function Code AsciiManufacturer Model Capacity Rotation Appendix 7 Compatible HDD BrandsLimited Warranty Lorex Product Limited WarrantyCare & Maintenance