Record Settings

On the Main menu, selecting the Record option will allow you to set the quality and speed of recordings.

Pressing ENTER after scrolling to the Record option will bring up the following menu options:

(RECORD)

HDD Overwrite: NO

Record IPS: 25A

Record Quality: Normal

Alarm Rec IPS: 25A

Alarm Rec Quality: Normal

Motion Trigger Record: ON

HDD Overwrite Setup:

1.Press ENTER to confirm HDD OVERWRITE setup.

2.Press ? / ? to choose HDD OVERWRITE.

NO: When HDD full will stop recording

YES: When HDD full will overwrite the HDD recording

3.Press MENU to exit and confirm current operation.

4.Press MENU again to exit and close HDD OVERWRITE setup mode.

Record IPS Setup:

1.Press ENTER to confirm RECORD IPS setup.

2.Press ? / ? to choose IPS record speed. Note that ‘15A’ indicates 15 ips with audio.

NTSC: 25A, 15, 8, 4, 2, 1

PAL: 18A, 12, 6, 3, 2, 1

3.Press MENU to exit and confirm current operation.

4.Press MENU again to exit and close RECORD IPS setup mode.

Record Quality Setup

1.Press ENTER to confirm Record Quality setup.

2.Press? / ? to choose Record Quality level.

BEST, HIGH, NORMAL, BASIC

3.Press MENU to exit and confirm current operation.

4.Press MENU again to exit and close RECORD QUALITY setup mode.

Alarm REC IPS setup

1.Press ENTER to confirm ALARM REC IPS setup.

2.Press ? / ? to choose ALARM REC IPS record speed.

NTSC: 15A, 15, 8, 4, 2, 1

PAL: 12A, 12, 6, 3, 2, 1

3.Press MENU to exit and confirm current operation.

4.Press MENU again to exit and close ALARM REC IPS setup mode.

Alarm REC Quality setup

1.Press ENTER to confirm ALARM REC QUALITY setup.

2.Press? / ? to choose ALARM REC QUALITY level.

BEST, HIGH, NORMAL, BASIC

3.Press MENU to exit and confirm current operation.

4.Press MENU again to exit and close ALARM REC QUALITY setup mode.

Motion Trigger Record

1.Press ENTER to confirm MOTION TRIGGER RECORD setup.

2.Press? / ? to toggle the option between ON and OFF.

(Menu) Search Timer

?Record Alarm Remote System Event

15

Image 16
Contents Channel Digital Video Recorder DXR109 L3R 4C1 Canada Table of Contents Important Safety Instructions Features IntroductionSystem Contents Front Panel Controls LED Indicators Pause / UpSlow Camera SelectBack Panel Connections Accessing the Main Menu System Set Up Setting the Internal Audible Alarm BuzzerSetting the External Audible Alarm device Selecting the Audio Input ChannelSetting the Motion Audible Alarm feature Setting the Alarm DurationSetting the Dwell Time Setting the Message Latch featureChanging the System Password Resetting System to Factory DefaultsJan-01 Mon Clearing the Hard Drive DataRemote Protocol Setup Timer Recording SetupBEST, HIGH, NORMAL, Basic Ntsc 15A, 15, 8, 4, 2 PAL 12A, 12, 6, 3, 2Record Settings HDD Overwrite SetupRecord IPS Setup Record Quality SetupCamera Channel Setup Alarm PolarityTitle DwellMotion Detection Setup Motion DetectionMotion Detection Setup 1~9 2MOTION Detection Setup LineHDD Error System ErrorPower Restore HDD WarningOperation Alarm List Picture in Picture PIPZoom Video SearchSlow reverse Image JogPause StopTroubleshooting Problem SolutionTechnical Specifications YY/NN/DD, DD/MM/YY, MM/DD/YY, OFFCartridge Casing Appendix 1 Installing the HDDRemove the Cartridge Casing from the DXR109 Slide the top Cover over the Cartridge Casing Secure the HDD in the cartridge casingLock the Cartridge Appendix 2 Connection Diagram to Cameras and Monitor Appendix 3 Pin Configurations Pin References for RS-232 / Alarm Block Appendix 4 Rack Mount Installation Appendix 5 Recording Times in Hours Ntsc SystemAppendix 6 RS232 Remote Protocol Function Code AsciiManufacturer Model Capacity Rotation Appendix 7 Compatible HDD BrandsLimited Warranty Lorex Product Limited WarrantyCare & Maintenance