Maytag P24 NMSU-E, PEFY-P06, P15, P12, P18, P08 operation manual Contents, Safety precautions

Page 4

Contents

1.

Safety precautions

4

 

3.4.

Fan speed adjustment

6

 

1.1.

Installation

4

 

3.5.

Ventilation

6

 

1.2.

During operation

4

 

3.6.

Others

6

 

1.3. Disposing of the unit

5

4.

The smart way to use

7

2.

Names and functions of various parts

5

5.

Caring for the machine

7

3.

How to operate

5

6.

Troubleshooting

8

 

3.1.

ON/OFF

5

7.

Installation, transferring works, and checking

9

 

3.2.

Selecting operation

5

8.

Specifications

9

 

3.3.

Room temperature adjustment

6

 

 

 

 

1. Safety precautions

GB

sBefore operating the unit, make sure you read all the “Safety precautions”.

s“Safety precautions” lists important points about safety. Please be sure to follow them.

Symbols used in the text

Warning:

Describes precautions that should be observed to avoid the risk of injury or death to the user.

Caution:

Describes precautions that should be observed to prevent damage to the unit.

Symbols used in the illustrations

: Indicates an action that must be avoided.

: Indicates that important instructions must be followed.

: Indicates a part which must be grounded.

: Indicates that caution should be taken with rotating parts. (This symbol is displayed on the main unit label.) <Color: yellow>

: Beware of electric shock. (This symbol is displayed on the main unit label.) <Color: yellow>

Warning:

Carefully read the labels affixed to the main unit.

1.1. Installation

sAfter you have read this manual, keep it and the Installation Manual in a safe place for easy reference whenever a question arises. If the unit is going to be operated by another person, make sure that this manual is given to him or her.

Warning:

The unit should not be installed by the user. Ask the dealer or an author- ized company to install the unit. If the unit is installed improperly, water leakage, electric shock or fire may result.

Use only accessories authorized by Mitsubishi Electric and ask your dealer or an authorized company to install them. If accessories are in- stalled improperly, water leakage, electric shock or fire may result.

The Installation Manual details the suggested installation method. Any structural alteration necessary for installation must comply with local building code requirements.

Never repair the unit or transfer it to another site by yourself. If repair is performed improperly, water leakage, electric shock or fire may result. If you need to have the unit repaired or moved, consult your dealer.

Keep the electric parts away from water (washing water) etc.

It might result in electric shock, catching fire or smoke.

Note1: When washing the Heat Exchanger and Drain Pan, ensure the Con- trol Box, Motor and LEV remain dry, using a water proof covering.

Note2: Never drain the washing water for the Drain Pan and the Heat Exchanger using the Drain Pump. Drain separately.

The appliance is not intended for use by young children or infirm per- sons without supervision.

Young children should be supervised to ensure that they do not play with the appliance.

Do not use a leak detection additive.

Caution:

The outdoor unit should be installed in a location where air and noise emit- ted by the unit will not disturb the neighbours.

2) Indoor unit

Warning:

The indoor unit should be securely installed. If the unit is loosely mounted, it may fall, causing injury.

3) Remote controller

Warning:

The remote controller should be installed in such a way that children cannot play with it.

4) Drain hose

Caution:

Make sure that the drain hose is installed so that drainage can go ahead smoothly. Incorrect installation may result in water leakage, causing dam- age to furniture.

5) Power line, fuse or circuit breaker

Warning:

Make sure that the unit is powered by a dedicated supply. Other appli- ances connected to the same supply could cause an overload.

Make sure that there is a main power switch.

Be sure to adhere to the unit’s voltage and fuse or circuit breaker ratings. Never use a piece of wire or a fuse with a higher rating than the one specified.

6) Grounding

Caution:

The unit must be properly grounded. Never connect the grounding wire to a gas pipe, water pipe, lightning conductor or telephone grounding wire. If the unit is not grounded properly, electric shock may result.

Check frequently that the ground wire from the outdoor unit is properly connected to both the unit’s ground terminal and the grounding electrode.

1.2. During operation

Caution:

Do not use any sharp object to push the buttons, as this may damage the remote controller.

Do not twist or tug on the remote controller cord as this may damage the remote controller and cause malfunction.

Never remove the upper case of the remote controller. It is dangerous to remove the upper case of the remote controller and touch the printed circuit boards inside. Doing so can result in fire and failure.

Never wipe the remote controller with benzene, thinner, chemical rags, etc. Doing so can result in discoloration and failure. To remove heavy stains, soak a cloth in neutral detergent mixed with water, wring it out thoroughly, wipe the stains off, and wipe again with a dry cloth.

Never block or cover the indoor or outdoor unit’s intakes or outlets. Tall items of furniture underneath the indoor unit, or bulky items such as large boxes placed close to the outdoor unit will reduce the unit’s effi- ciency.

1) Outdoor unit

Warning:

Warning:

• Do not splash water over the unit and do not touch the unit with wet

• The outdoor unit must be installed on a stable, level surface, in a place

hands. An electric shock may result.

where there is no accumulation of snow, leaves or rubbish.

• Do not spray combustible gas close to the unit. Fire may result.

• Do not stand on, or place any items on the unit.You may fall down or the

• Do not place a gas heater or any other open-flame appliance where it will

item may fall, causing injury.

be exposed to the air discharged from the unit. Incomplete combustion

 

may result.

4

KB79K384H01_en.p65

4

08.1.24, 1:20 PM

Image 4
Contents Indoor Unit ON/OFF PEFY-P-NMSU-E Contents Safety precautionsHow to operate Names and functions of various partsDisposing of the unit ON/OFFFan speed adjustment Room temperature adjustmentVentilation OthersSmart way to use Caring for the machineTroubleshooting Following symptoms are not air conditioner failuresInstallation, transferring works, and checking SpecificationsRegarding place for installation Maintenance and inspectionConsignes de sécurité Table des matièresPendant le fonctionnement Comment faire fonctionner le climatiseur Noms et fonctions des différents élémentsRangement de l’appareil Sélection du mode de fonctionnement ON/OFF marche/arrêtRéglage de la température de la pièce Réglage de la vitesse du ventilateurEntretien de l’appareil Comment utiliser le climatiseur intelligemmentAutres Guide de dépannage OFFPropos de l’emplacement de l’installation Propos de l’installation électriqueVérification et maintenance Spécifications techniquesKB79K384H01

P08, P24 NMSU-E, P18, P12, P15 specifications

The Maytag PEFY series, which includes models P06, P12, P18, P15, and P24, along with the NMSU-E, represents a significant advancement in the realm of heating and cooling solutions. Renowned for their reliable performance, these systems cater to both residential and commercial applications, ensuring optimal indoor comfort year-round.

One of the main features of the Maytag PEFY series is their exceptional energy efficiency. Equipped with advanced inverter technology, these units adjust their operating capacity based on the current demands of the space, minimizing energy consumption while maintaining a comfortable environment. This not only leads to lower utility bills but also reduces the carbon footprint, aligning with modern sustainability goals.

The PEFY series is designed with versatility in mind. These heat pump systems can efficiently switch between heating and cooling modes, making them an ideal choice for varying climate conditions. The multi-zone capability allows for tailored climate control in different rooms or areas, enhancing comfort while optimizing energy use. This is particularly beneficial for larger properties where different rooms may have different heating and cooling needs.

In terms of design, Maytag has ensured that the PEFY units are compact and unobtrusive. Their sleek profiles allow for easy installation in various settings, whether it be in a commercial space or within a home. The low noise operation is another hallmark feature, providing quiet comfort without disturbing occupants. This is complemented by a user-friendly interface that allows for effortless temperature adjustments and system monitoring.

The NMSU-E model builds on these features by incorporating advanced control technologies, including smart connectivity options. Users can remotely operate and manage their HVAC systems through smartphone applications, allowing for complete control of home or office comfort from anywhere. This integration with smart home ecosystems enhances convenience and adaptability.

Additionally, the PEFY series comes equipped with robust safety features, including refrigerant leak detection and automatic restart capabilities, ensuring continuous and safe operation. The durable construction materials used in the units provide added reliability and longevity, making them a sound investment for property owners.

In conclusion, the Maytag PEFY-P06, P12, P18, P15, P24, and NMSU-E models are distinguished by their energy efficiency, versatile heating and cooling capabilities, sleek design, and smart technology integration. They represent the future of HVAC solutions, providing comfort while addressing environmental concerns and user convenience.