Maytag P18, PEFY-P06, P15, P12, P08 Installation, transferring works, and checking, Specifications

Page 9

7. Installation, transferring works, and checking

Regarding place for installation

Consult with your dealer for details on installation and transferring the installation.

Caution:

Never install the air conditioner where there is a risk of leakage of flammable gas.

If gas leaks and accumulates around the unit, fire can result.

Never install the air conditioner at the following place:

where there is a lot of machine oil

near the ocean and beach areas where there is salt air.

where humidity is high

where there are hot springs nearby

where there is sulphurous gas

where there is a high-frequency processing machinery (a high-frequency welder, etc.)

where acid solution is frequently used

where special sprays are frequently used

Install the indoor unit horizontally. Otherwise, water leakage can result.

Take sufficient measures against noise when installing the air conditioners at hospitals or communication-related businesses.

If the air conditioner is used in any of the above-mentioned environments, frequent operational failure can be expected. It is advisable to avoid these types of installa- tion sites.

For further details, consult with your dealer.

Regarding electrical work

Caution:

The electrical work must be undertaken by a person who is qualified as an electrical engineer according to the [technical standard respecting electrical installation], [internal wiring rules], and the installation instruc- tion manual with the absolute use of exclusive circuits. The use of other products with the power source can result in burnt-out beakers and fuses.

Never connect the grounding wire to a gas pipe, water pipe, arrester, or telephone grounding wire. For details, consult with your dealer.

In some types of installation sites, the installation of an earth leakage breaker is mandatory. For details, consult with your dealer.

Regarding transfer of installation

When removing and reinstalling the air conditioner when you enlarge your home, remodel, or move, consult with your dealer in advance to ascertain the cost of the professional engineering work required for transferring the installa- tion.

Caution:

When moving or reinstalling the air conditioner, consult with your dealer. Defective installation can result in electric shock, fire, etc.

Regarding noise

In installing work, choose a place that can fully bear the weight of the air con- ditioner, and where noise and vibration can be reduced.

Choose a place where cool or warm air and noise from the outdoor air outlet of the air conditioner does not inconvenience the neighbors.

If any alien object is placed near the outdoor air outlet of the air conditioner, decreased performance and increased noise can result. Avoid placing any obstacles adjacent to the air outlet.

If the air conditioner produces any abnormal sound, consult with your dealer.

Maintenance and inspection

If the air conditioner is used throughout several seasons, the insides can get dirty, reducing the performance.

Depending upon the conditions of usage, foul odors can be generated and drainage can deteriorate due to dust and dirt, etc.

GB

8. Specifications

PEFY-P-NMSU-E series

Item

 

 

 

Model

P06NMSU-E

P08NMSU-E

P12NMSU-E

P15NMSU-E

P18NMSU-E

P24NMSU-E

Power source

 

 

 

 

208, 230V 60Hz

 

 

Cooling capacity*1/Heating capacity*1

 

BTU/h

6,000/6,700

8,000/9,000

12,000/13,500

15,000/17,000

18,000/20,000

24,000/27,000

 

 

 

 

kW

1.8/2.0

2.3/2.6

3.5/4.0

4.4/5.0

5.3/5.9

7.0/7.9

 

 

 

Height

mm [in]

200 [7-7/8]

200 [7-7/8]

200 [7-7/8]

200 [7-7/8]

200 [7-7/8]

200 [7-7/8]

Dimension

Width

mm [in]

790 [31-1/8]

790 [31-1/8]

790 [31-1/8]

990 [39]

990 [39]

1,190 [46-7/8]

 

 

 

Depth

mm [in]

700 [27-9/16]

700 [27-9/16]

700 [27-9/16]

700 [27-9/16]

700 [27-9/16]

700 [27-9/16]

Net weight

 

kg [Ib]

19 [42]

19 [42]

20 [46]

24 [54]

24 [54]

28 [62]

Fan

Airflow rate (Low-Middle-High)

 

CFM

176-212-247

194-247-317

211-282-370

282-335-388

353-441-529

423-565-706

External static pressure*2

 

Pa

5/15/35/50

5/15/35/50

5/15/35/50

5/15/35/50

5/15/35/50

5/15/35/50

 

 

Noise level (Low-Middle-High)*2 *3

 

dB(A)

22-24-28

23-26-30

23-28-35

28-30-33

30-34-37

30-35-40

Filter

 

 

 

 

 

 

Standard filter

 

 

Notes: *1 Cooling/Heating capacity indicates the maximum value at operation under the following condition.

 

 

 

 

Cooling: Indoor: 80 °F (26.7 °C) D.B./67 °F (19.4 °C) W.B.

Outdoor: 95 °F (35 °C) D.B.

 

 

 

 

 

Heating: Indoor: 70 °F (21.1 °C) D.B.

 

Outdoor: 47 °F (8.3 °C) D.B./43 °F (6.1 °C) W.B.

 

 

 

 

Pipe length: 7.5 m (24-9/16 ft)

Height difference: 0m (0 ft)

 

 

 

 

 

*2 The external static pressure is set to 0.04 in. WG (15 Pa) at factory shipment. *3 The operating noise is the data that was obtained in an anechoic room.

9

KB79K384H01_en.p65

9

08.2.26, 11:15 AM

Image 9
Contents Indoor Unit ON/OFF PEFY-P-NMSU-E Safety precautions ContentsNames and functions of various parts How to operateDisposing of the unit ON/OFFRoom temperature adjustment Fan speed adjustmentVentilation OthersCaring for the machine Smart way to useFollowing symptoms are not air conditioner failures TroubleshootingSpecifications Installation, transferring works, and checkingRegarding place for installation Maintenance and inspectionTable des matières Consignes de sécuritéPendant le fonctionnement Noms et fonctions des différents éléments Comment faire fonctionner le climatiseurRangement de l’appareil ON/OFF marche/arrêt Sélection du mode de fonctionnementRéglage de la température de la pièce Réglage de la vitesse du ventilateurComment utiliser le climatiseur intelligemment Entretien de l’appareilAutres OFF Guide de dépannagePropos de l’installation électrique Propos de l’emplacement de l’installationVérification et maintenance Spécifications techniquesKB79K384H01

P08, P24 NMSU-E, P18, P12, P15 specifications

The Maytag PEFY series, which includes models P06, P12, P18, P15, and P24, along with the NMSU-E, represents a significant advancement in the realm of heating and cooling solutions. Renowned for their reliable performance, these systems cater to both residential and commercial applications, ensuring optimal indoor comfort year-round.

One of the main features of the Maytag PEFY series is their exceptional energy efficiency. Equipped with advanced inverter technology, these units adjust their operating capacity based on the current demands of the space, minimizing energy consumption while maintaining a comfortable environment. This not only leads to lower utility bills but also reduces the carbon footprint, aligning with modern sustainability goals.

The PEFY series is designed with versatility in mind. These heat pump systems can efficiently switch between heating and cooling modes, making them an ideal choice for varying climate conditions. The multi-zone capability allows for tailored climate control in different rooms or areas, enhancing comfort while optimizing energy use. This is particularly beneficial for larger properties where different rooms may have different heating and cooling needs.

In terms of design, Maytag has ensured that the PEFY units are compact and unobtrusive. Their sleek profiles allow for easy installation in various settings, whether it be in a commercial space or within a home. The low noise operation is another hallmark feature, providing quiet comfort without disturbing occupants. This is complemented by a user-friendly interface that allows for effortless temperature adjustments and system monitoring.

The NMSU-E model builds on these features by incorporating advanced control technologies, including smart connectivity options. Users can remotely operate and manage their HVAC systems through smartphone applications, allowing for complete control of home or office comfort from anywhere. This integration with smart home ecosystems enhances convenience and adaptability.

Additionally, the PEFY series comes equipped with robust safety features, including refrigerant leak detection and automatic restart capabilities, ensuring continuous and safe operation. The durable construction materials used in the units provide added reliability and longevity, making them a sound investment for property owners.

In conclusion, the Maytag PEFY-P06, P12, P18, P15, P24, and NMSU-E models are distinguished by their energy efficiency, versatile heating and cooling capabilities, sleek design, and smart technology integration. They represent the future of HVAC solutions, providing comfort while addressing environmental concerns and user convenience.