Raypak PS-4 PS-8 installation manual Before Startup, Program Automatic Operation, Heater Checkout

Page 29

6. System Startup and Checkout

Before Startup

Before starting theAqua Logic for the first time, be sure that the following items have been completed:

1.Pool/spa chemicals are within the recommended levels according to the chart on page 3.

2.Pool/spa salt level is between 2700 – 3400 PPM.

3.Properly rated circuit breakers are installed in theAqua Logic subpanel.

4.All wiring is performed according to NEC and local codes.

5.TheAqua Logic is properly grounded and bonded.

6.TheAqua Logic is properly configured to control all desired functions.

Program Automatic Operation

Refer to the programming flow chart on the back cover of this manual for a listing of the available menus and the items included in each menu.

Settings Menu

Heater(s) and/or solar thermostat settings

Chlorinator settings

Day and Time

Timers Menu

Timeclock and/or Countdown timer settings

Heater Checkout

Follow these instructions to verify that theAqua Logic is properly controlling the heater.

1.Check that theAqua Logic is calling for the heater to turn on as indicated by the “Heater” LED being illuminated. If the “Heater” LED is illuminated, go directly to step 2; if not, then check the following:

The heater is enabled (Configuration Menu/Heater Config.)

The heater temperature setting is at least 2ºF greater than the water temperature (Settings Menu / Pool Heater & Spa Heater)

The filter pump is running

If the pool has solar heat and the solar priority feature is enabled (Configuration Menu/Solar Config) then solar must be off in order for the heater to fire. The easiest way to force solar off is to go to the Settings Menu / Pool Solar & Spa Solar and temporarily lower the temperature settings below the current water temperature.

2.Check that the heater is running. If not, then check:

Power is supplied to the heater.

TheAqua Logic control output is properly connected to the heater control (see”Heater Control” wiring, page 13)

Some heaters also have internal switches or jumpers that have to be set correctly for remote control operation—refer to the heater manual and also “Heater Control” (page 13)

Heater is turned on (“Kill Switch” is in the “ON” position)

If a heater bypass valve is installed, check that water is flowing through the heater

The heater temperature setting is set as high as possible (usually 104ºF/40ºC). Also note that some heatpumps actually have be set to the lowest possible temperature.

26

Image 29
Contents Aqua Logic Important Safety Instructions Table of Contents Before You Begin Before installing the Aqua Logic SystemWhat’s Included What’s not IncludedElectrical Requirements Installation StepsPlumbing Requirements Water Chemistry General Water ChemistrySalt Level SaltGallons Liters Aqua Logic Control Center Temperature SensorsOptional Wired Remote Display/Keypad Optional Valve Actuators Optional Wireless Remote Display/KeypadOptional Base Receiver General Pool Equipment PlumbingTurbo Cell Flow SwitchMain Service Power to the Circuit Breaker Subpanel Electrical WiringAqua Logic Control Power Circuit Breaker Installation and WiringGrounding and Bonding General Purpose Outlet240 VAC 120 VAC High Voltage 120/240V Pool EquipmentHeater Control Low Voltage WiringValveActuators Laars Heaters most models except LX Generic HeatersPentair/Purex/MiniMax Hayward HeatersSTA-RITE Heater Raypak RP2100 Pool/Spa HeaterWired Remote Display/Keypad Temperature SensorsTurbo Cell Flow SwitchBase Receiver Configuration Menu Items Accessing the Configuration MenuTo access the Configuration Menu ChlorinatorHeater Name Heater1Heater Cooldown Heater ExtendSolar Extend SolarSolar Priority Pool/SpaFilter Operation Spa SpilloverLights Name Lights FunctionAux1 Function Aux1 NameAux1 Freeze Protection Aux1 InterlockValve3 Name Valve3 FunctionValve3 Freeze Protection Valve3 InterlockHeater Checkout Before StartupProgram Automatic Operation Interference FCC StatementIndustry Canada Statement Limited Warranty-Pool Automation & Chlorination Products Aqua Logic Programming Flow Chart

PS-4 PS-8 specifications

Raypak, a leader in the heating and water temperature control industry, offers a robust line of products featuring state-of-the-art technology and efficiency. Among its notable offerings are the Raypak PS-4 and PS-8 models, which are designed to meet a variety of heating demands in residential and commercial settings.

The Raypak PS-4 and PS-8 are both part of the Performance Series and are designed for versatility. These models utilize high-efficiency gas burners that not only maximize heat output but also minimize fuel consumption. This efficiency is crucial for both cost savings and environmental sustainability, making these heaters an excellent choice for mindful consumers and businesses.

One of the standout features of the PS-4 and PS-8 is their user-friendly digital display, which provides real-time information about system performance. This allows users to easily monitor and adjust settings, ensuring optimal operation at all times. Additionally, these models come equipped with advanced diagnostics that aid in troubleshooting and maintenance, reducing downtime and improving overall system reliability.

The PS-4 model has a heating capacity of up to 400,000 BTU, while the PS-8 boasts an impressive capacity of 800,000 BTU. This wide range of output makes them suitable for a variety of applications, from residential pools to large commercial facilities. Both models feature a durable, rust-resistant cabinet designed to withstand the elements, further enhancing their longevity and performance.

In terms of technology, both heaters are designed with an innovative control system that allows for precise temperature management. Additionally, they feature a built-in fan, which helps distribute heat evenly throughout the space. This ensures that users enjoy consistent temperatures, whether in a pool or spa setting.

The PS-4 and PS-8 models also focus on safety, incorporating multiple safety mechanisms such as high limit sensors and a robust electronic ignition system. These features help prevent issues such as overheating and ensure the system operates safely and reliably.

In conclusion, the Raypak PS-4 and PS-8 models exemplify modern engineering in the heating industry. With their combination of high efficiency, advanced technology, and user-friendly design, they are excellent choices for anyone looking to improve their heating solutions in both residential and commercial applications. Whether for pool heating or spa use, the Raypak heaters promise reliability, performance, and long-lasting service.