Raypak HD101, HD401 operating instructions General Information, Quantity of Burners Vent Size Flue

Page 7

General Information

 

Model

 

Quantity of Burners

 

Vent Size (in.)

 

 

 

 

 

 

No.

 

 

Flue

 

Intake

 

 

 

 

 

 

HD101

 

2

 

4

 

 

 

 

HD151

 

3

 

4

 

 

 

 

HD201

 

4

 

5

 

4

 

 

HD251

 

5

 

5

 

 

 

HD301

 

6

 

5

 

 

 

 

HD401

 

8

 

6

 

 

 

 

 

 

Table A: Basic Data

 

 

 

 

 

Fig. 4: Air Shutter Adjustment

Fig. 5: Gas Valves

7

Image 7
Contents Installation & Operating Instructions Deletions None Contents Are important but not related to personal injury hazards Model Identification Before InstallationInstallations at Elevation Product ReceiptComponent Locations Angle View Component LocationsQuantity of Burners Vent Size Flue General InformationTime/Temperature Relationships in Scalds General SafetyWater Time to Produce Serious Temp Burn Equipment Base InstallationInstallation Codes Indoor/Closet InstallationsMinimum Installed Service Clearance Outdoor Installations Outdoor InstallationsConventional Combustion Air Supply Combustion and Ventilation AirWater Piping Installations in CanadaGeneral Relief Valve Piping Reversing Water ConnectionsHydronic Heating Maximum 4 times the pipe diameter or 12, whichever is less Air-Separation/Expansion Tank Domestic Hot Water PipingPiping-Heating Boilers Three-Way ValvesGas Supply Connection Gas SupplyHeater transformer. do not attach line voltage to Electrical Power ConnectionsGas Pressure Regulator Gas Supply PressureTable H Maximum Equivalent Pipe Length Check the Power SourceSurge Protection Making the Electrical ConnectionsConduit should not be used as the ground. There Electrical Connections Domestic Hot WaterDefinition of Appliance Categories VentingSupport of Vent Stack Barometric DamperVent Terminal Location Table J Vent/Air Inlet Termination Clearances US Installations Venting Configurations Venting Installation TipsNatural Draft Vertical Vent Termination Natural Draft Vertical Venting System InstallationInches Length feet Appliance CertifiedHorizontal Thru-wall Direct Vent Termination Inches Length ModelCombustion Air Inlet Venting Air Intake CategoryLength Material Inches Min Max Feet Model Appliance CertifiedMin./Max. Vertical Combustion Air Inlet Venting Height feetVertical Direct Vent System Installation Outdoor InstallationVertical Direct Vent Termination Ignition Control Module High Limit Manual ResetHigh Limit Auto Reset Optional ControlsHigh and Low Gas Pressure Switches Optional Flow SwitchLow Water Cut Off Optional Wiring DIAGRAM-MODELS HD101-HD401 HD101-HD401 Troubleshooting Initial START-UP PRE-START-UPPage Start-Up Main Burner AdjustmentGas Type Conversion on Valve Safety InspectionFollow-Up Post START-UP CheckAir Filter Inspection/Removal Remove the Screws and Panel Heat Exchanger RemovalYearly Beginning of each heating MaintenanceMaintenance Schedule Suggested MinimumMonthly AppendixInside Combustion Air Contamination DailyPage Important Instructions for the Commonwealth of Massachusetts Page
Related manuals
Manual 4 pages 39.79 Kb Manual 4 pages 39.54 Kb Manual 8 pages 40.56 Kb Manual 48 pages 22.97 Kb

HD101, HD401 specifications

Raypak is renowned for its commitment to high-quality heating solutions, with the HD101 and HD401 models standing out in their product range. These units are designed specifically for commercial applications, providing reliable and efficient hydronic heating systems. The HD series embodies innovation while addressing the unique demands of larger spaces.

One of the main features of the HD101 and HD401 is their stainless steel construction, which ensures increased durability and resistance to corrosion. This design choice enhances the longevity of the units, making them ideal for various installations in commercial or industrial settings.

Both models are equipped with a high-efficiency heat exchanger that maximizes heat transfer while minimizing energy consumption. This feature is particularly significant in today’s environmentally conscious market, as it contributes to lower operating costs and reduced carbon footprints. The heat exchangers are engineered for easy maintenance, offering simplicity when service is required.

In terms of technology, the HD101 and HD401 include advanced digital controls that allow for precise temperature regulation. This user-friendly interface enables operators to easily manage and monitor heating parameters, facilitating optimal performance and energy management.

The models also feature modulating burners that adjust their output according to the heating demand. This capacity for modulation results in smoother operation and an overall increase in efficiency, as the burners can maintain consistent temperatures without excessive energy use.

Another noteworthy characteristic is their compatibility with various control systems, including BMS (Building Management Systems). This adaptability allows for seamless integration into existing infrastructure, providing users with greater versatility and control over their heating environments.

Both the HD101 and HD401 come with advanced safety features, including flame rollback protection and pressure monitoring, ensuring safe operation even in demanding conditions. Additionally, their compact design allows for easy installation in limited spaces while still providing powerful heating capabilities.

Ultimately, the Raypak HD101 and HD401 are exceptional choices for those in need of high-efficiency commercial heating solutions. With their robust construction, advanced technology, and user-friendly features, these models promise to deliver reliable performance and energy savings for years to come. Whether for a large facility or a specific industrial application, they stand ready to meet the heating challenges of today’s commercial landscape.