Raypak 0090A Gas Supply Connections, Model No Nat Pro, 0090 125 300 400 560 0135 150 200 0195 100

Page 11

(g)Any improper operation of the common venting system should be corrected so the installation conforms with the latest edition of the National Fuel Gas Code, ANSI Z223.1. When re-sizing any portion of the common venting system, the com- mon venting system should be re-sized to approach the minimum size as determined using the appropriate tables in Chapter 10 and in Appendix G of the National Fuel Gas Code, ANSI Z223.1 and CAN/CSA-B149.

Gas Supply Connections

The inlet gas connection to the heater gas valve is 1/2". Provide an adequate gas supply line according to Table F below.

Gas piping must have a sediment trap ahead of the heater gas controls, and a manual shut-off valve locat- ed outside the heater jacket. All gas piping should be tested after installation in accordance with local codes.

CAUTION: The heater and its manual shut off valve must be disconnected from the gas supply during any pressure testing of that system at test pressures in excess of 1/2 psi (3.45 kPa). Dissipate test pressure in the gas supply line before reconnecting the heater and its manual shut off valve to gas supply line. FAILURE TO FOLLOW THIS PROCEDURE MAY DAMAGE THE GAS VALVE. OVER PRESSURED GAS VALVES ARE NOT COVERED BY WARRANTY. The heater and its gas connections shall be leak tested before placing the appliance in operation. Use soapy water for leak test DO NOT use open flame.

SUPPLIED BY

INSTALLER

Fig. 6: Sediment Trap

NOTE: Do not use teflon tape on gas line pipe thread. A flexible sealant suitable for use with Natural and Propane gases is recommended.

NOTE: These heaters are also certified to operate on Propane gas, when equipped with the combination gas valve and orifices (pilot and main burners) sized for Propane gas.

Model No.

1/2 in.

3/4 in.

1 in.

 

1-1/4 in.

 

 

 

 

 

 

 

 

 

Nat

Pro

Nat

Pro

Nat

 

Pro

Nat

Pro

 

 

 

 

 

 

 

 

 

 

 

 

0090

30

80

125

300

400

 

560

 

 

 

 

 

 

 

 

 

 

 

 

0135

15

40

60

150

150

 

200

 

 

 

 

 

 

 

 

 

 

 

 

0195

 

20

35

70

100

 

100

400

 

 

 

 

 

 

 

 

 

 

 

Natural gas, 1000 BTUH/ft .60 specific gravity @ 0.5 in. WC pressure drop.

Propane gas, 2500 BTUH/ft 1.53 specific gravity @ 0.6 in. WC pressure drop.

Table F: Maximum Equivalent Pipe Length (ft)

11

Image 11
Contents Econopak Water Heaters Page Contents Are important but not related to personal injury hazards Solution to check all gas fittings and connectionsBe corrected. When smelling to detect an propane Cations and their installation should beTemperature Time to Produce Serious Burn General SafetyTime/Temperature Relationships in Scalds Receiving Equipment General SpecificationsWH-0090 WH-0135 132 WH-0195 192 Piping Connections DimensionsInput Recovery Tank Gph Gal Water Gas VentClearances InstallationCode Requirements Mounting Base0090 0135 0195 Vent Max Model No Connector Horizontal Diameter Length ftVenting Connections Model No Sq. in. of Each Free AreaVenting Minimum Clearances Common Vents0090 125 300 400 560 0135 150 200 0195 100 Gas Supply ConnectionsModel No Nat Pro Natural 10.5 Propane 12.0 13.0 11.0 Gas Pressure Specifications Type Inches WC Regulator MinSetting Water Connections & System PipingRelief Valve Electrical WiringTemperature & Pressure Gauge Wiring Diagram-Standing Pilot-Models 0090, 0135 Wiring Diagram-IID-Models 0090, 0135 Sequence of Operation Servicing ProceduresStart-up Procedures Honeywellpilot Robertshaw Pilot For Automatic Ignition Models System Shut Down ProcedureLighting the Heater For Standing Pilot ModelsAll Models To Turn Off Gas to HeaterFor Honeywell Gas Valve Turn gas control knob Counter-clockwise to onInspection Procedures Testing the Ignition Safety Shut-offMain Burner and Orifice Removal Normal Inspection ProceduresProcedure for Cleaning Flue Gas Passage Ways Burner Drawer RemovalHeat Exchanger Removal Tube Cleaning Procedure TypicalHeat Exchanger Re-Assembly Repair SectionCauses TroubleshootingPiping Adjustments & Replacement of Components Eastman Avenue Oxnard, CA Circulator ReplacementReplacement Parts Limitedpartswarrantyeconopakwaterheaters

0090A, 0135A, 0195A specifications

Raypak is a leading manufacturer in the pool and spa industry, known for its reliable and innovative heating solutions. Among its product line, the Raypak 0090A, 0135A, and 0195A are notable models that stand out for their efficiency, durability, and advanced technology.

The Raypak 0090A is ideal for residential pools, offering a heat output of 90,000 BTU per hour. It utilizes a copper heat exchanger, which provides efficient heat transfer and is resistant to corrosion, making it perfect for chlorinated pools. This model features a digital thermostat that enhances user control, allowing for precise temperature settings. Additionally, the 0090A is compatible with both natural gas and propane, providing flexibility depending on user preference.

The Raypak 0135A, with its 135,000 BTU output, is designed for larger residential pools or smaller commercial applications. This model employs advanced energy-efficient technology, helping to reduce operational costs while maintaining optimal heating performance. One of the key features of the 0135A is its built-in electronic ignition system, which improves reliability and eliminates the need for a standing pilot, enhancing safety and efficiency. The unit's compact design allows it to fit in tight spaces while still providing robust heating capabilities.

The Raypak 0195A is the most powerful of the trio, delivering 195,000 BTU, making it suitable for larger pool setups and high-demand environments. It also uses a copper heat exchanger, ensuring excellent heat retention and durability against corrosion. The 0195A is equipped with an easy-to-use digital display, offering intuitive controls for temperature adjustments and operational monitoring. This model also incorporates a high-tech air intake design, which maximizes airflow and reduces energy consumption.

All three models are designed for outdoor installation and possess weather-resistant features, ensuring longevity and reliability through various environmental conditions. Additionally, they are equipped with easy access service panels for maintenance, ensuring that servicing is efficient and straightforward.

In summary, Raypak's 0090A, 0135A, and 0195A models are designed to meet diverse heating needs with advanced technology, energy efficiency, and robust construction, making them excellent choices for anyone looking to enhance their pool experience.