Raypak 0195A, 0135A, 0090A operating instructions Receiving Equipment, General Specifications

Page 6

DANGER: There is a Hot Water SCALD Potential if the tankstat is set too high.

CAUTION: Hotter water increases the risk of

SCALDING!

NOTE: When this heater is supplying general purpose hot water requirements for use by individuals, a thermostatically controlled mixing valve for reducing point of use water temperature is recommended to reduce the risk of scald injury. Contact a licensed plumber or the local plumbing authority for further information.

RECEIVING EQUIPMENT

On receipt of your equipment it is suggested that you visually check for external damage to the carton. If the carton is damaged, it is suggested that a note be made on the Bill of Lading when signing for equipment. Remove the heater from the carton and if it is dam- aged report the damage to the carrier immediately. Be sure that you receive the number of packages indicat- ed on the Bill of Lading. Claims for shortages and damages must be filed with carrier by consignee.

Purchased parts are subject to replacement only under the manufacturer's warranty. Debits for defec- tive replacement parts will not be accepted and defective parts will be replaced in kind only per our standard warranties.

When ordering parts, you must specify Model and Serial Number of the heater. When ordering under

warranty conditions, you must also specify date of installation.

Raypak recommends that this manual be reviewed thoroughly before installing your Raypak heater. If there are any questions which this manual does not answer, please contact your local Raypak representa- tive.

GENERAL

SPECIFICATIONS

The Raypak water heaters are design certified by the and tested under the requirements of the American National Standard, ANSI Z21.10.3. Each heater has been constructed and pressure tested in accordance with the requirements of Section IV of the American Society of Mechanical Engineers Code, and factory fire tested.

These heaters are designed for indoor and outdoor installations, and can be installed on combustible floor- ing when the appropriate listed floor shield base is used.

Models are available with standing pilot or with inter- mittent ignition device (IID), and are equipped with the following components as standard: water circulation pump, pressure relief valve, manual reset high limit switch, flow switch, vent thermal and flame roll-out switches, 40VA transformer, and redundant combina- tion gas valve for use with either Natural or Propane gases. A tankstat is supplied loose for installation in the field.

6

Image 6
Contents Econopak Water Heaters Page Contents Cations and their installation should be Solution to check all gas fittings and connectionsBe corrected. When smelling to detect an propane Are important but not related to personal injury hazardsGeneral Safety Time/Temperature Relationships in ScaldsTemperature Time to Produce Serious Burn General Specifications Receiving EquipmentGph Gal Water Gas Vent Piping Connections DimensionsInput Recovery Tank WH-0090 WH-0135 132 WH-0195 192Mounting Base InstallationCode Requirements ClearancesModel No Sq. in. of Each Free Area Vent Max Model No Connector Horizontal Diameter Length ftVenting Connections 0090 0135 0195Common Vents Venting Minimum ClearancesGas Supply Connections Model No Nat Pro0090 125 300 400 560 0135 150 200 0195 100 Water Connections & System Piping Gas Pressure Specifications Type Inches WC Regulator MinSetting Natural 10.5 Propane 12.0 13.0 11.0Electrical Wiring Temperature & Pressure GaugeRelief Valve Wiring Diagram-Standing Pilot-Models 0090, 0135 Wiring Diagram-IID-Models 0090, 0135 Servicing Procedures Start-up ProceduresSequence of Operation Honeywellpilot Robertshaw Pilot For Standing Pilot Models System Shut Down ProcedureLighting the Heater For Automatic Ignition ModelsCounter-clockwise to on To Turn Off Gas to HeaterFor Honeywell Gas Valve Turn gas control knob All ModelsTesting the Ignition Safety Shut-off Inspection ProceduresBurner Drawer Removal Normal Inspection ProceduresProcedure for Cleaning Flue Gas Passage Ways Main Burner and Orifice RemovalRepair Section Tube Cleaning Procedure TypicalHeat Exchanger Re-Assembly Heat Exchanger RemovalTroubleshooting CausesPiping Adjustments & Replacement of Components Circulator Replacement Replacement PartsEastman Avenue Oxnard, CA Limitedpartswarrantyeconopakwaterheaters

0090A, 0135A, 0195A specifications

Raypak is a leading manufacturer in the pool and spa industry, known for its reliable and innovative heating solutions. Among its product line, the Raypak 0090A, 0135A, and 0195A are notable models that stand out for their efficiency, durability, and advanced technology.

The Raypak 0090A is ideal for residential pools, offering a heat output of 90,000 BTU per hour. It utilizes a copper heat exchanger, which provides efficient heat transfer and is resistant to corrosion, making it perfect for chlorinated pools. This model features a digital thermostat that enhances user control, allowing for precise temperature settings. Additionally, the 0090A is compatible with both natural gas and propane, providing flexibility depending on user preference.

The Raypak 0135A, with its 135,000 BTU output, is designed for larger residential pools or smaller commercial applications. This model employs advanced energy-efficient technology, helping to reduce operational costs while maintaining optimal heating performance. One of the key features of the 0135A is its built-in electronic ignition system, which improves reliability and eliminates the need for a standing pilot, enhancing safety and efficiency. The unit's compact design allows it to fit in tight spaces while still providing robust heating capabilities.

The Raypak 0195A is the most powerful of the trio, delivering 195,000 BTU, making it suitable for larger pool setups and high-demand environments. It also uses a copper heat exchanger, ensuring excellent heat retention and durability against corrosion. The 0195A is equipped with an easy-to-use digital display, offering intuitive controls for temperature adjustments and operational monitoring. This model also incorporates a high-tech air intake design, which maximizes airflow and reduces energy consumption.

All three models are designed for outdoor installation and possess weather-resistant features, ensuring longevity and reliability through various environmental conditions. Additionally, they are equipped with easy access service panels for maintenance, ensuring that servicing is efficient and straightforward.

In summary, Raypak's 0090A, 0135A, and 0195A models are designed to meet diverse heating needs with advanced technology, energy efficiency, and robust construction, making them excellent choices for anyone looking to enhance their pool experience.