Raypak 0133-4001 manual For Your Safety Read Before Operating, Operating Instructions

Page 32

LIGHTING INSTRUCTIONS FOR HEATERS WITH ELECTRONIC IGNITION (IID)

FOR MODELS WITH MANUAL GAS VALVES

FOR YOUR SAFETY READ BEFORE OPERATING

WARNING:If you do not follow these instructions exactly, a fire or explosion may result causing property damage, personal injury or loss of life.

A.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

B.BEFORE OPERATING smell all around the appliance area for gas. Be sure to smell next to the floor because

some gas is heavier than air and will settle on the floor.

WHAT TO DO IF YOU SMELL GAS

*Do not try to light any appliance.

*Do not touch any electric switch.

*Do not use any phone in your building.

*Immediately call your gas supplier from your neighbor’s phone. Follow the gas supplier’s instruc- tions.

*If you cannot reach your gas supplier, call the fire de- partment.

C.Use only your hand to push in or turn the gas control knob. Never use tools. If the knob will not push in or turn by hand, do not try to repair it. Call a qualified service technician. Force or attempted repair may result in a fire or explosion.

D.Do not use this appliance if any part has been under water. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water.

OPERATING INSTRUCTIONS

1.STOP! Read the safety information above.

2.Set the thermostat on the lowest setting.

3.Turn off all electric power to the appliance.

4.This appliance is equipped with an ignition device which automatically lights the pilot. Do not try to light the pilot by hand.

5.Remove heater door panel.

6.For Robertshaw gas valve: Turn gas control knob

clockwise to “OFF”.

For Honeywell Gas Valve: Turn gas control knob clock-

wise to “OFF". Make sure knob rests against stop. For Honeywell Gas Valve: (Model 400 only)

Push in gas control knob slightly and turn clockwise

to “OFF”. Knob cannot be turned to “OFF” unless knob is pushed in slightly. Do not force.

7.Wait five (5) minutes to clear out any gas. Then smell for gas, including near the floor. If you smell gas, STOP! Follow “B” in the safety information previously stated. If you do not smell gas, go to the next step.

8.For Robertshaw Gas Valve: Turn gas control knob

counter-clockwise to “ON”.

ROBERT SHAW

GAS CONTROL

KNOB SHOWN

IN "ON" POSITION

GAS INLET

Fig. # 8080

For Honeywell Gas Valve: Turn gas control knob counter-

clockwise

from “OFF” until it stops. Push in gas control

knob and continue rotating counter-clockwise

to “ON”

position. Make sure knob rests against stop.

 

HONEYWELL

GAS CONTROL

KNOB SHOWN

IN "ON" POSITION

GAS INLET

Fig. # 8082

9.Replace heater door panel.

10.Turn on all electric power to the appliance.

11.Set thermostat to desired setting.

12.If the appliance will not operate, follow the instructions “To Turn Off Gas To Appliance” and call your service technician or gas supplier.

TO TURN OFF GAS TO APPLIANCE

1.

Set the thermostat to the lowest setting.

For Honeywell Gas Valve: Turn gas control knob clock-

2.

Turn off all the electric power to the appliance if service

wise

to “OFF”. Make sure knob rests against

 

is to be performed.

stop.

 

3.Remove door panel.

4. For Robertshaw Gas Valve: Turn gas control knob 5. Replace heater door panel.

clockwise

to “OFF”.

32

Image 32
Contents Installation Operating Instructions For Your SafetyTable of Contents General Specifications Receiving Equipment ALL Models ApprovedModel Identification HOT Water Supply HeatersGeneral Safety Precautions Installation Instructions Installation CodesClearances Specifications and Dimensions ModelModels Models Outdoor Water Heaters High Wind Conditions Outdoor Units OnlyOutdoor Installations VentingIndoor Installations Before After Installation DrafthoodVent TERMINAL/INDOOR Stack Installation Vent Piping Fig. #7043.1Vent Damper Installation Models 133 Through 180 Where Required LocationVent Damper GAS Supply Connections PlumbingGeneral GAS Pressure Regulator Venting of Diaphragm GAS ComponentsFlow Rates General Specifications UNI-TEMP 80 HOT Water Supply Systems Piping Domestic HOT Water Supply HeatersPiping Diagrams Type WH Unitemp 80 System Type NH Instantaneous Minimum Input Adjustment Type NH Dual ModelsControls General Relief ValveElectronic Ignition Economaster ControlFlow Switch 100% Pilot SafetyHigh and LOW GAS Pressure Switches Optional Limit Controls High LimitComponent Identification ON/OFF Units Electrical ConnectionsSINGLE-STAGE Tankstat 400 WH1, WH2, WH3 LOW NOx WH1 Location of ControlsFig. #9334 Location of Controls START-UP Procedures Before START-UP Initial START-UP Pump and MotorTIME/TEMPERATURE Relationships in Scalds ScaldingFor Your Safety Read Before Operating Operating InstructionsTo Turn OFF GAS to Appliance For Models with Manual GAS ValvesInspection Procedures Burners After START-UPControls For Models with Automatic GAS ValvesInspection Procedures Burner Adjustment High GAS Pressure SwitchSTART-UP Procedures Visual InspectionBurner Tray Removal Pilot RemovalGAS Valve Removal Main Burner and Orifice RemovalTroubleshooting Electrical Honeywell S8600Wiring Diagrams Wiring Diagram WH2 182/260 Wiring Diagram WH2 330/400 Wiring Diagram WH2 514/624 Wiring Diagram WH2 Wiring Diagram WH2 Wiring Diagram WH2 Wiring Diagram WH2 Wiring Diagram WH1 181/261 LOW NOx Wiring Diagram WH1 331/401 LOW NOx Troubleshooting Mechanical Problem Possible Cause Corrective ActionTube Cleaning Troubleshooting PumpsService and Maintenance Procedures Pilot Removal and Cleaning High Limit or Tankstat RemovalHeat Exchanger Removal Typical Burner Tray IllustratedTube Replacement Heat Exchanger RE-ASSEMBLYControl Well Replacement Catalog Model Number Cleaning Flue GAS PassagewaysReplacement Parts Warranty Scope

0133-4001 specifications

Raypak 0133-4001 is a high-performance pool and spa heater designed for efficient and reliable heating. As part of Raypak's commitment to quality and innovation, this model combines advanced technologies and features to ensure optimal heating and energy efficiency.

One of the primary features of the Raypak 0133-4001 is its durable construction. Crafted from corrosion-resistant materials, this heater is built to withstand harsh weather conditions, ensuring longevity and minimal maintenance. This durability is particularly beneficial for outdoor installations, where exposure to the elements is a concern.

The Raypak 0133-4001 is equipped with a powerful heating capacity, making it suitable for both residential and commercial applications. With its robust output, it can quickly raise the temperature of a pool or spa, allowing for extended use even during cooler months. This rapid heating capability is complemented by its adjustable temperature settings, enabling users to customize their experience based on individual preferences.

Another significant characteristic of the Raypak 0133-4001 is its advanced digital control system. The intuitive interface allows for easy operation and precise temperature adjustments. Users can monitor settings and make adjustments with just a few button presses, ensuring convenience and usability. Additionally, this model often features built-in diagnostics, providing users with real-time feedback on the heater's performance and any necessary maintenance alerts.

Energy efficiency is a hallmark of the Raypak 0133-4001. This model is designed to minimize energy consumption while delivering maximum heating output. With its innovative heat exchanger technology, it optimizes the transfer of heat, reducing operational costs over time. This focus on energy efficiency not only benefits users financially but also promotes environmentally sustainable practices.

The Raypak 0133-4001 heater is compatible with a variety of pool and spa systems, making it a versatile choice for different setups. Its ease of installation and compatibility with standard plumbing connections simplify the integration process, whether for new installations or upgrades to existing systems.

In conclusion, the Raypak 0133-4001 is an excellent choice for those seeking a reliable, efficient, and user-friendly pool and spa heater. With its robust construction, powerful heating capabilities, advanced digital controls, and emphasis on energy efficiency, it stands out as a premier option in the market. Whether for residential or commercial use, the Raypak 0133-4001 is engineered to enhance the enjoyment and comfort of your swimming experience.