Raypak 0133-4001 manual Troubleshooting, Mechanical Problem Possible Cause Corrective Action

Page 47

TROUBLESHOOTING

MECHANICAL PROBLEM

POSSIBLE CAUSE

CORRECTIVE ACTION

 

 

 

When heater is turned on nothing

No power to the heater………………….

Check the circuit breaker, outdoor con-

happens.

 

troller, etc., upstream of heater.

 

Bad transformer………………………….

If power to Leads L1 and L2 of trans-

 

 

former, but no power on 24V side, re-

 

 

place.

 

Inoperative thermostat…………………..

Jumper thermostat, replace with new if

 

 

heater fires.

 

Inoperative toggle switch………………..

If power to toggle switch, but not through

 

 

switch, replace.

 

Inoperative relay…………………………. If power to relay, but not operating, re-

 

 

place.

 

 

 

Thermostat in "ON" position causes relay and pump to operate, but heater does not fire.

Main gas valve closed………………...... Open valve.

Plugged bleed line on gas valve or

gas pressure regulator………………….. Loosen bleed line and clean.

Broken pump coupler…………………… Replace coupler. Inspect bearing as-

sembly, and if frozen, lubricate or re- place.

Shutdown by low water cut-off,

caused by air…………………………….. Bleed air from system.

Gas valve defective…………………….. Check for power to gas valve. If valve has

power but will not open, check vent tube for blockage. If clear, replace valve.

Continuous shut down of manual

Temperature setting too low…………….

Reset High Limit to higher temperature.

reset High Limit.

Low water flow……………………………

Check system water pumps.

 

Interrupted pump operation……………..

Check pump oil if necessary.

 

Modulating control set too high………..

Reset modulator to a lower setting.

 

Mechanical modulating control…………

Check and replace if necessary.

 

 

 

Sooting

Air starvation……………………………..

CAUTION-Soot may be combus-

 

tible. Wet down and exercise

Condensation…………………………….

caution when cleaning.

Toxic fumes which cause a chemical

 

reaction with copper tubes or destroy

 

combustion……………………………….

 

Improper venting…………………………

Refer to installation instructions regard- ing combustion air requirements.

Set bypass valve to prevent heater inlet temperature from dropping below 105° F.

Remove all sources of fumes, such as freon or chloride, or isolate the heater. Follow recommended vent installation instructions.

Continuous shut down of low water

Insufficient system flow………………….

Check pumps and piping.

cut-off or flow switch.

Low water due to leaking………………..

Inspect for leaking and repair.

 

Air in system……………………………...

Inspect for leakage and repair. Install an

 

 

automatic air vent.

 

Line strainer dirty…………………………

Clean.

 

Lime in Heat Exchanger…………………

Ream tubes.

 

 

 

Low flame.

Outer jacket very hot (blistered paint)

Combustion fan not running. (If applicable)

Low gas supply………………………….. Debris in gas line (pipe dope, rocks, etc.).

Gas line too small. Improper size gas meter. Gas regulator adjustment.

Insects or debris clogging………………. Clean burners.

Burner intake ports low gas pressure…. Adjust gas pressure.

Venting or combustion air………………. Refer to installation instructions regard-

 

ing combustion air requirement.

Broken refractory…..…………………….

Replace refractory panels.

Fan relay

Replace fan relay.

Fan

Loose wire connection.

 

Failed fan motor.

47

Image 47
Contents For Your Safety Installation Operating InstructionsTable of Contents HOT Water Supply Heaters General SpecificationsReceiving Equipment ALL Models Approved Model IdentificationGeneral Safety Precautions Installation Codes Installation InstructionsClearances Model Specifications and DimensionsModels Models High Wind Conditions Outdoor Units Only Outdoor Water HeatersVenting Outdoor InstallationsBefore After Installation Drafthood Indoor InstallationsVent TERMINAL/INDOOR Stack Installation Fig. #7043.1 Vent PipingModels 133 Through 180 Where Required Location Vent Damper InstallationVent Damper GAS Supply Connections PlumbingGeneral Venting of Diaphragm GAS Components GAS Pressure RegulatorFlow Rates Piping Domestic HOT Water Supply Heaters General Specifications UNI-TEMP 80 HOT Water Supply SystemsPiping Diagrams Type WH Unitemp 80 System Type NH Instantaneous Type NH Dual Models Minimum Input AdjustmentEconomaster Control Controls GeneralRelief Valve Electronic IgnitionLimit Controls High Limit Flow Switch100% Pilot Safety High and LOW GAS Pressure Switches OptionalComponent Identification ON/OFF Units Electrical ConnectionsSINGLE-STAGE Tankstat Location of Controls 400 WH1, WH2, WH3 LOW NOx WH1Fig. #9334 Initial START-UP Pump and Motor Location of Controls START-UP Procedures Before START-UPScalding TIME/TEMPERATURE Relationships in ScaldsFor Models with Manual GAS Valves For Your Safety Read Before OperatingOperating Instructions To Turn OFF GAS to ApplianceFor Models with Automatic GAS Valves Inspection Procedures BurnersAfter START-UP ControlsInspection Procedures Visual Inspection Burner AdjustmentHigh GAS Pressure Switch START-UP ProceduresMain Burner and Orifice Removal Burner Tray RemovalPilot Removal GAS Valve RemovalHoneywell S8600 Troubleshooting ElectricalWiring Diagrams Wiring Diagram WH2 182/260 Wiring Diagram WH2 330/400 Wiring Diagram WH2 514/624 Wiring Diagram WH2 Wiring Diagram WH2 Wiring Diagram WH2 Wiring Diagram WH2 Wiring Diagram WH1 181/261 LOW NOx Wiring Diagram WH1 331/401 LOW NOx Mechanical Problem Possible Cause Corrective Action TroubleshootingTube Cleaning Troubleshooting PumpsService and Maintenance Procedures Typical Burner Tray Illustrated Pilot Removal and CleaningHigh Limit or Tankstat Removal Heat Exchanger RemovalTube Replacement Heat Exchanger RE-ASSEMBLYControl Well Replacement Catalog Model Number Cleaning Flue GAS PassagewaysReplacement Parts Scope Warranty

0133-4001 specifications

Raypak 0133-4001 is a high-performance pool and spa heater designed for efficient and reliable heating. As part of Raypak's commitment to quality and innovation, this model combines advanced technologies and features to ensure optimal heating and energy efficiency.

One of the primary features of the Raypak 0133-4001 is its durable construction. Crafted from corrosion-resistant materials, this heater is built to withstand harsh weather conditions, ensuring longevity and minimal maintenance. This durability is particularly beneficial for outdoor installations, where exposure to the elements is a concern.

The Raypak 0133-4001 is equipped with a powerful heating capacity, making it suitable for both residential and commercial applications. With its robust output, it can quickly raise the temperature of a pool or spa, allowing for extended use even during cooler months. This rapid heating capability is complemented by its adjustable temperature settings, enabling users to customize their experience based on individual preferences.

Another significant characteristic of the Raypak 0133-4001 is its advanced digital control system. The intuitive interface allows for easy operation and precise temperature adjustments. Users can monitor settings and make adjustments with just a few button presses, ensuring convenience and usability. Additionally, this model often features built-in diagnostics, providing users with real-time feedback on the heater's performance and any necessary maintenance alerts.

Energy efficiency is a hallmark of the Raypak 0133-4001. This model is designed to minimize energy consumption while delivering maximum heating output. With its innovative heat exchanger technology, it optimizes the transfer of heat, reducing operational costs over time. This focus on energy efficiency not only benefits users financially but also promotes environmentally sustainable practices.

The Raypak 0133-4001 heater is compatible with a variety of pool and spa systems, making it a versatile choice for different setups. Its ease of installation and compatibility with standard plumbing connections simplify the integration process, whether for new installations or upgrades to existing systems.

In conclusion, the Raypak 0133-4001 is an excellent choice for those seeking a reliable, efficient, and user-friendly pool and spa heater. With its robust construction, powerful heating capabilities, advanced digital controls, and emphasis on energy efficiency, it stands out as a premier option in the market. Whether for residential or commercial use, the Raypak 0133-4001 is engineered to enhance the enjoyment and comfort of your swimming experience.