Minimum clearances between the water heater and combustible construction are 0 inch at the sides and rear, 4 inches (102 mm) at the front, and 6 inches (153 mm) from the vent pipe. Clearance from the top of the jacket is 12 inches (305 mm) on most models. Note that a lesser dimension may be allowed on some models, refer to the label attached adjacent to the gas control valve on the water heater, see Figure 9.

FIGURE9.

Install water heater in accordance with the instruction manual and NFPA54.

To avoid injury, combustion and ventilation air must be taken from outdoors.

Do not place chemical vapor emitting products near water heater.

A gas water heater cannot operate properly without the correct amount of air for combustion. Do not install in a confined area such as a closet, unless you provide air as shown in the Locating The New Water Heater section. Never obstruct the flow of ventilation air. If you have any doubts or questions at all, call your gas supplier. Failure to provide the proper amount of combustion air can result in a fire or explosion and cause death, serious bodily injury, or property damage.

FIGURE10.

If this water heater will be used in beauty shops, barber shops, cleaning establishments, or self-service laundries with dry cleaning equipment, it is imperative that the water heater or water heaters be installed so that combustion and ventilation air be taken from outside these areas.

Propellants of aerosol sprays and volatile compounds, (cleaners, chlorine based chemicals, refrigerants, etc.) in addition to being highly flammable in many cases, will also change to corrosive hydrochloric acid when exposed to the combustion products of the water heater. The results can be hazardous, and also cause product failure.

Insulation Blankets

Do not obstruct water heater air intake with insulating blanket.

Gas and carbon monoxide detectors are available.

Install water heater in accordance with the instruction manual.

Insulation blankets available to the general public for external use on gas water heaters are not necessary with Maytag products. The purpose of an insulation blanket is to reduce the standby heat loss encountered with storage tank heaters. Your Maytag water heater meets or exceeds the National Appliance Energy Conservation Act standards with respect to insulation and standby loss requirements, making an insulation blanket unnecessary.

Should you choose to apply an insulation blanket to this heater, you should follow these instructions (See Figure 7 for identification of components mentioned below). Failure to follow these instructions can restrict the air flow required for proper combustion, potentially resulting in fire, asphyxiation, serious personal injury or death.

Do not apply insulation to the top of the water heater, as this will interfere with safe operation of the draft hood.

Do not cover the outer door, thermostat or temperature & pressure relief valve.

Do not allow insulation to come within 2” (50.8 mm) of the floor to prevent blockage of combustion air flow to the burner.

Do not cover the instruction manual. Keep it on the side of the water heater or nearby for future reference.

Do obtain new warning and instruction labels from Maytag for placement on the blanket directly over the existing labels.

Do inspect the insulation blanket frequently to make certain it does not sag, thereby obstructing combustion air flow.

11

Image 11
Contents Series Twelve Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsTools Accessories and Tools NeededAccessories Additional Tools Needed When Sweat SolderingRemoving the Old Water Heater Instructions for InstallationGET to Know Your Water Heater GAS Models Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings Water Piping Customer Service 1-800-788-8899. Follow manufacturer’sValve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions For Your Safety Read Before LightingTemperature Time to Produce 2nd & 3rd Temperature RegulationVent System Inspection Service and MaintenanceTank Sediment Cleaning Burner CleaningDraining Temperature-Pressure Relief Valve OperationHousekeeping Anode Rod InspectionStart Up Conditions TroubleshootingDrain Valve Washer Replacement ServiceSmoke / Odor Operational ConditionsLeakage Checkpoints High Temperature Shut Off SystemProblem Cause Solution Troubleshooting GuidePage Page Maytag GAS Water Heaters Repair Parts ListModel Numbers MAYTAG/STATE Part Number Conversion KEY Warranty

HRN31250X, HRN11250X, HRP11250Q, HRP31250X, HRN31250Q specifications

The Maytag HRP11240X, HRP31250X, HRP11250Q, HRN11250X, and HRN11240X are a range of high-performance refrigerators designed to meet the needs of modern households. These models are well-known for their reliability, innovative features, and user-friendly design, making them a popular choice among consumers looking for durable refrigeration solutions.

One of the standout features of these Maytag models is their robust construction, which includes a stainless-steel exterior that not only offers a sleek appearance but also resists fingerprints, making it easy to maintain. The interiors are spacious and designed for optimal organization, with adjustable shelving that allows for customizable storage options. Families can easily store large items, such as party trays and oversized bottles, thanks to the flexible space configurations.

All these models are equipped with Maytag's PowerCold feature, which quickly cools the refrigerator after the door has been open for an extended period. This technology is especially beneficial during grocery trips, ensuring that perishables remain fresh and properly chilled. In addition, the temperature management system ensures consistent cooling by monitoring temperature fluctuations and adjusting accordingly.

The HRP11250Q and HRP31250X also come with the advanced FreshLock crispers, which are designed to maintain optimal humidity levels for fruits and vegetables, prolonging their freshness. The humidity-controlled environment is crucial for preserving the taste and nutrition of your produce.

Further enhancing the user experience, the Maytag refrigerators feature a bright LED interior lighting system, allowing users to easily find items even in the back of the fridge. The EnergyStar certification on these models indicates that they are energy-efficient, helping to lower utility bills while also being eco-friendly.

The models HRN11250X and HRN11240X offer additional convenience with their easy-to-use digital controls located at the front, providing intuitive access to adjust settings quickly. They also feature a reversible door hinge option, giving homeowners flexibility in installation and ensuring the refrigerator fits seamlessly into their kitchen layout.

Overall, the Maytag HRP11240X, HRP31250X, HRP11250Q, HRN11250X, and HRN11240X refrigerators exhibit a great blend of functionality, style, and durability, making them an excellent investment for any household. With their advanced technologies and thoughtful design features, these models are tailored to enhance everyday life while ensuring food preservation is taken care of efficiently.