Maytag HRP31250Q, HRN11240X, HRN11250Q, HRP31240X, HRP11240X, HRP11250X, HRN31240X manual Gas Piping

Page 17

There must be a minimum of 6 inches (153 mm) clearance between single wall vent pipe and any combustible material. Fill and seal any clearance between single wall vent pipe and combustible material with mortar mix, cement, or other noncombustible substance. For other than single wall, follow vent pipe manufacturer’s clearance specifications. To insure a tight fit of the vent pipe in a brick chimney, seal around the vent pipe with mortar mix cement.

Failure to have required clearances between vent piping and combustible material will result in a fire hazard.

Be sure vent pipe is properly connected to prevent escape of dangerous flue gases which could cause deadly asphyxiation.

Chemical vapor corrosion of the flue and vent system may occur if air for combustion contains certain chemical vapors. Spray can propellants, cleaning solvents, refrigerator and air conditioner refrigerants, swimming pool chemicals, calcium and sodium chloride, waxes, bleach and process chemicals are typical compounds which are potentially corrosive.

Gas Piping

Make sure the gas supplied is the same type listed on the model rating plate. The inlet gas pressure must not exceed 14 inch water column (2.6kPa) for natural and propane gas (L.P.) gas. The minimum inlet gas pressure listed on the rating

plate is for the purpose of input adjustment. If the gas control valve is subjected to pressures exceeding 1/2 pound per square inch (3.5kPa), the damage to the gas control valve could result in a fire or explosion from leaking gas.

If the main gas line Shut-off serving all gas appliances is used, also turn “OFF” the gas at each appliance. Leave all gas appliances shut “OFF” until the water heater installation is complete.

A gas line of sufficient size must be run to the water heater. Consult the current edition of National Fuel Gas Code ANSI Z223.1/NFPA 54 and your gas supplier concerning pipe size.

There must be:

A readily accessible manual shut off valve in the gas supply line serving the water heater, and

A drip leg (sediment trap) ahead of the gas control valve to help prevent dirt and foreign materials from entering the gas control valve.

A flexible gas connector or a ground joint union between the shut off valve and control valve to permit servicing of the unit.

Be sure to check all the gas piping for leaks before lighting the water heater. Use a soapy water solution, not a match or open flame. Rinse off soapy solution and wipe dry.

The minimum inlet gas pressure shown on the rating plate is that which will permit firing at the rated input.

If a standard model is installed above 3,300 feet (1,006 m) or a high altitude model is installed above 5,500 feet (1,676 m) the input rating should be reduced at the rate of 4 percent for each 1,000 feet (305 m ) above sea level which requires replacement of the burner orifice in accordance with National Fuel Gas Code ANSI Z223.1/NFPA 54. Contact Maytag Customer Service

Center at 1-800-788-8899 or your local gas supplier or call for further information.

Failure to replace the standard orifice with a high altitude orifice when installed at elevations above 3,300 feet (1,006 m) or above 5,500 feet (1,676 m) for high altitude model could result in improper and inefficient operation of the appliance, producing carbon monoxide gas in excess of safe limits, which could result in serious injury or death. Contact Maytag Customer

Service at 1-800-788-8899 or your local gas supplier for any specific changes which may be required in your area.

17

Image 17
Contents Series Twelve Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsAccessories Accessories and Tools NeededAdditional Tools Needed When Sweat Soldering ToolsRemoving the Old Water Heater Instructions for InstallationGET to Know Your Water Heater GAS Models Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings Water Piping Customer Service 1-800-788-8899. Follow manufacturer’sValve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions For Your Safety Read Before LightingTemperature Time to Produce 2nd & 3rd Temperature RegulationTank Sediment Cleaning Service and MaintenanceBurner Cleaning Vent System InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingDrain Valve Washer Replacement TroubleshootingService Start Up ConditionsSmoke / Odor Operational ConditionsLeakage Checkpoints High Temperature Shut Off SystemProblem Cause Solution Troubleshooting GuidePage Page Maytag GAS Water Heaters Repair Parts ListModel Numbers MAYTAG/STATE Part Number Conversion KEY Warranty

HRN31250X, HRN11250X, HRP11250Q, HRP31250X, HRN31250Q specifications

The Maytag HRP11240X, HRP31250X, HRP11250Q, HRN11250X, and HRN11240X are a range of high-performance refrigerators designed to meet the needs of modern households. These models are well-known for their reliability, innovative features, and user-friendly design, making them a popular choice among consumers looking for durable refrigeration solutions.

One of the standout features of these Maytag models is their robust construction, which includes a stainless-steel exterior that not only offers a sleek appearance but also resists fingerprints, making it easy to maintain. The interiors are spacious and designed for optimal organization, with adjustable shelving that allows for customizable storage options. Families can easily store large items, such as party trays and oversized bottles, thanks to the flexible space configurations.

All these models are equipped with Maytag's PowerCold feature, which quickly cools the refrigerator after the door has been open for an extended period. This technology is especially beneficial during grocery trips, ensuring that perishables remain fresh and properly chilled. In addition, the temperature management system ensures consistent cooling by monitoring temperature fluctuations and adjusting accordingly.

The HRP11250Q and HRP31250X also come with the advanced FreshLock crispers, which are designed to maintain optimal humidity levels for fruits and vegetables, prolonging their freshness. The humidity-controlled environment is crucial for preserving the taste and nutrition of your produce.

Further enhancing the user experience, the Maytag refrigerators feature a bright LED interior lighting system, allowing users to easily find items even in the back of the fridge. The EnergyStar certification on these models indicates that they are energy-efficient, helping to lower utility bills while also being eco-friendly.

The models HRN11250X and HRN11240X offer additional convenience with their easy-to-use digital controls located at the front, providing intuitive access to adjust settings quickly. They also feature a reversible door hinge option, giving homeowners flexibility in installation and ensuring the refrigerator fits seamlessly into their kitchen layout.

Overall, the Maytag HRP11240X, HRP31250X, HRP11250Q, HRN11250X, and HRN11240X refrigerators exhibit a great blend of functionality, style, and durability, making them an excellent investment for any household. With their advanced technologies and thoughtful design features, these models are tailored to enhance everyday life while ensuring food preservation is taken care of efficiently.