Maytag HRN11250Q, HRN11240X Water Piping, Customer Service 1-800-788-8899. Follow manufacturer’s

Page 13

FIGURE14.

Louvers and Grilles: In calculating free area, consideration shall be given to the blocking effect of louvers, grilles or screens protecting openings. Screens used shall not be smaller than 1/4 inch (6.4 mm) mesh. If the free area through a design of louver or grille is known, it should be used in calculating the size opening required to provide the free area specified. If the design and free area is not known, it may be assumed that wood louvers will be 20-25 percent free area and metal louvers and grilles will have 60-75 percent free area. Louvers and grilles shall be fixed in the open position or interlocked with the equipment so that they are opened automatically during equipment operation.

Special Conditions Created by Mechanical Exhausting or Fireplaces: operation of exhaust fans, ventilation systems, clothes dryers or fireplaces may create conditions requiring special attention to avoid unsatisfactory operation of installed gas utilization equipment.

Water Piping

HOTTER WATER CAN SCALD:

Water heaters are intended to produce hot water. Water heated to a temperature which will satisfy space heating, clothes washing, dish washing, cleaning and other sanitizing needs can scald and permanently injure you upon contact. Some people are more likely to be permanently injured by hot water than others. These include the elderly, children, the infirm, or physically/mentally handicapped. If anyone using hot water in your home fits into one of these groups or if there is a local code or state law requiring a certain temperature water at the hot water tap, then you must take special precautions. In addition to using the lowest possible temperature setting that

satisfies your hot water needs, a means such as a *mixing valve, shall be used at the hot water taps used by these people or at the water heater. Mixing valves are available at plumbing supply or hardware stores, see Figure 8 on page 9 and Figure 15 below. Valves for reducing point of use temperature by mixing cold and hot water are also available. Consult Maytag

Customer Service (1-800-788-8899). Follow manufacturer’s

instructions for installation of the valves. Before changing the factory setting on the thermostat, read the Temperature Regulation section in this manual.

FIGURE15.

This water heater shall not be connected to any heating systems or component(s) used with a non-potable water heating appliance.

Toxic chemicals, such as those used for boiler treatment shall not be introduced into this system.

Water supply systems may, because of such events as high line pressure, frequent cut-offs, the effects of water hammer among others, have installed devices such as pressure reducing valves, check valves, back flow preventers, etc. to control these types of problems. When these devices are not equipped with an internal by-pass, and no other measures are taken, the devices cause the water system to be closed. As water is heated, it expands (thermal expansion) and closed systems do not allow for the expansion of heated water.

The water within the water heater tank expands as it is heated and increases the pressure of the water system. If the relieving point of the water heater’s temperature-pressure relief valve is reached, the valve will relieve the excess pressure. The temperature-pressure relief valve is not intended for the constant relief of thermal expansion. This is an unacceptable condition and must be corrected. It is recommended that any devices installed which could create a closed system have a by-pass and/or the system have an expansion tank to relieve the pressure built by thermal expansion in the water system. Refer to the Thermal Expansion section under Troubleshooting Guide or contact local plumbing authority or call Maytag

Customer Service at 1-800-788-8899 for an authorized installer on how to control this situation.

13

Image 13
Contents Series Twelve Important Definitions Safe INSTALLATION, USE and ServiceSafety Precautions Table of Contents Customer Responsibilities Product SpecificationsAccessories Accessories and Tools NeededAdditional Tools Needed When Sweat Soldering ToolsRemoving the Old Water Heater Instructions for InstallationGET to Know Your Water Heater GAS Models Typical InstallationMixing Valve Usage Facts to Consider About the Location Locating the NEW Water HeaterInsulation Blankets ALL AIR from Inside Buildings Water Piping Customer Service 1-800-788-8899. Follow manufacturer’sValve and Pipe Insulation Temperature-Pressure Relief ValveFilling the Water Heater Venting Gas Piping Sediment Traps GAS Piping with Flexible ConnectorOperating Instructions For Your Safety Read Before LightingTemperature Time to Produce 2nd & 3rd Temperature RegulationTank Sediment Cleaning Service and MaintenanceBurner Cleaning Vent System InspectionHousekeeping Temperature-Pressure Relief Valve OperationAnode Rod Inspection DrainingDrain Valve Washer Replacement TroubleshootingService Start Up ConditionsSmoke / Odor Operational ConditionsLeakage Checkpoints High Temperature Shut Off SystemProblem Cause Solution Troubleshooting GuidePage Page Maytag GAS Water Heaters Repair Parts ListModel Numbers MAYTAG/STATE Part Number Conversion KEY Warranty

HRN31250X, HRN11250X, HRP11250Q, HRP31250X, HRN31250Q specifications

The Maytag HRP11240X, HRP31250X, HRP11250Q, HRN11250X, and HRN11240X are a range of high-performance refrigerators designed to meet the needs of modern households. These models are well-known for their reliability, innovative features, and user-friendly design, making them a popular choice among consumers looking for durable refrigeration solutions.

One of the standout features of these Maytag models is their robust construction, which includes a stainless-steel exterior that not only offers a sleek appearance but also resists fingerprints, making it easy to maintain. The interiors are spacious and designed for optimal organization, with adjustable shelving that allows for customizable storage options. Families can easily store large items, such as party trays and oversized bottles, thanks to the flexible space configurations.

All these models are equipped with Maytag's PowerCold feature, which quickly cools the refrigerator after the door has been open for an extended period. This technology is especially beneficial during grocery trips, ensuring that perishables remain fresh and properly chilled. In addition, the temperature management system ensures consistent cooling by monitoring temperature fluctuations and adjusting accordingly.

The HRP11250Q and HRP31250X also come with the advanced FreshLock crispers, which are designed to maintain optimal humidity levels for fruits and vegetables, prolonging their freshness. The humidity-controlled environment is crucial for preserving the taste and nutrition of your produce.

Further enhancing the user experience, the Maytag refrigerators feature a bright LED interior lighting system, allowing users to easily find items even in the back of the fridge. The EnergyStar certification on these models indicates that they are energy-efficient, helping to lower utility bills while also being eco-friendly.

The models HRN11250X and HRN11240X offer additional convenience with their easy-to-use digital controls located at the front, providing intuitive access to adjust settings quickly. They also feature a reversible door hinge option, giving homeowners flexibility in installation and ensuring the refrigerator fits seamlessly into their kitchen layout.

Overall, the Maytag HRP11240X, HRP31250X, HRP11250Q, HRN11250X, and HRN11240X refrigerators exhibit a great blend of functionality, style, and durability, making them an excellent investment for any household. With their advanced technologies and thoughtful design features, these models are tailored to enhance everyday life while ensuring food preservation is taken care of efficiently.