Instructions for Installation (cont'd)
Converting the Lower Element (cont'd)
7.The wire removed from terminal 2 has a looped end. It must remain looped and now be placed (as shown) on top
of the buss bar, over the opening of terminal 2, and secured using the remaining screw.
8.Tighten terminals 2 and 3 to ensure proper electrical con- nection.
_WARNING
Failure to tighten terminal screws can cause a fire I which can result in DEATH. SERIOUS BODILY INJURY,
OR PROPERTY DAMAGE.
9. Replace terminal cover on thermostat and fold insulation
back over the element making sure that the locking tabs on
the terminal cover are in place.
11. Replace the access panel.
_ | _1[ | _ | _ |
| _ | i |
12.Complete wiring to the water heater, or if completed, turn "ON" elech'ic power to the water heater after filling the
tank with water,
AWARNING
Make sure the thermostat is flush against the tank, I the terminal cover is in place, and the insulation is I replaced. Failure to do so can result in DEATH, SERI-
OUS BOD LY NJURY, OR PROPERTY DAMAGE.
|
|
|
| _, CAUTION |
| J | |
10. Fold the insulation | back in place so that it completely coy- | Never use this | water heater unless | it is completely | I | ||
ers the thermostat | and element, | full of | water. | To prevent | damage | to the tank and | I |
|
| heating | element, the tank | must be filled with water, | [ |
turning "ON" power.
Water must flow from the hot water faucet before
14