Service and Maintenance (cont'd)
Thermostat Adjustments |
| Relief |
If the upper thermostat is adjusted above the | Valve Operation |
|
factory preset |
| |
point of 1200F (Hot), it cannot be set higher | than the lower |
|
The
thermostat setting. Read all warnings in the "Temperature Regulation" section before proceeding.
ated at least once a year.
UPPERTHERMOSTAT
1.Turn "OFF" the electric power to the water heater at the junction box.
AWARNING
HAZARD OF ELECTRICAL SHOCK! Before removin(
any access panels or servicing the water heater
make sure the electrical supply to the water heate is turned "OFF". Failure to do this could result in
DEATH, SERIOUS BODILY INJURY, OR PROPERTY
DAMAGE,
2. Take offthe access panel and fold away the insulation.
3. The slotted adjustment (using a screwdriver) can be turned
clockwise (/'_"0 to increase the temperature setting or
counter clockwise (¢f_ to decrease the temperature setting,
4.Fold the insulation back in place and replace the access panel,
5.Turn "ON" the power supply,
LOWER THERMOSTAT
The adjustment dial can be turned | clockwise | (_) | to | |
increase | the temperature setting | or counter | clockwise | |
(_"_) | to decrease the temperature setting. |
|
|
/TEMPERATURE-PRESSURE
• | / / | RELIEFVALVE |
_ |
| __ |
DISCHARGEPIPE
AWARNING
The
manually operatedat least once a year. Caution should be taken to ensure that (1) no one is in front
of or around the outlet of the
sure relief valve discharge line, and (2) the water manually discharged will not cause any property
damage or bodi y njury The water may be
extremely hot.' If after manually operating the valve, it fails to completely reset and continues to release water, immediately close the cold water inlet to the water
heater, follow the draining instructions, and replace the
a new one.
Failure to install and maintain a new properly listed tempera-
any claim which might result from excessive temperature or pressure.
AWARNING]
If the
heater may have a check valve installed in the water line or a water meter with a check valve. Call [
Maytacj Customer Service at
pressure relief valve. | I |