Cleaning System using:
•Chlorine bleach (surface and municipal water)
•MAYTAG MC1 Cleaning Solution (ground water)
This procedure is to be conducted after the internal prefilter has been removed from the System. Do not permit the Carbon Prefilter to come into contact with chlorine bleach or any other form of chlorine. During this procedure the water level in the System should be half way up the internal prefilter cavity. If necessary, add water by slightly opening the inlet ball valve while observing the water level.
Always wear safety glasses and protective clothing when handling cleaning chemicals.
10.Add 500mL of household chlorine bleach to System (5.25% as Cl2) OR 250 mL of 12% chlorine pool bleach OR add the MAYTAG MC1 Cleaning Solution following instructions in the package.
Model | Cleaning Chemical Used | |
|
| |
MWF4100AWS and | Chlorine Bleach (5.25% as Cl2) | |
MWF4300AWS, any non- | Chlorine Pool Bleach (12% as | |
well water | ||
Cl2) | ||
| ||
MWF4200AWS, well | MAYTAG MC1 Cleaning | |
water only | Solution | |
|
|
Never intentionally or unintentionally mix chlorine bleach and
Chlorine bleach must be less than 3 months old. The active percentage reduces with time.
After the System has soaked it must be flushed as the sanitizing solution in the water supply may irritate the skin or cause illness if ingested.
Do not use hot water during maintenance of the System. It is possible that if a hot water tap is used, high levels of chlorine or MAYTAG MC1 Cleaning Solution will enter the hot water tank and cause personal injury, illness and/or death.
Soak 60 min. | 11. | Allow System to soak 60 minutes. Drain System for 5 minutes using the |
|
| controller as described in step 4. At the end of 5 minutes the System |
|
| Controller Manual indicator will turn off or the System Controller flashing |
|
| light will go out. |
| 12. | |
Prefilter. |
| replace System Cap. When installing a new replacement or a clean, |
|
| used internal prefilter, the spigot end of the prefilter (refer to Photo 3a |
and 3b on page 15), is carefully fitted into the inlet on the bottom of the prefilter cavity.
MAYTAG Whole Home Water Filtration System Owners Manual
November 2003
18