Maytag mwf4100aws owner manual November

Page 28

Replacement/Cleaning and System Cleaning Procedure” use the System controller and flush to drain for 5 minutes. To begin draining the household pipes, turn on a nearby cold water tap and leave it on until the tap only drips. Turn off the tap.

3.Remove the drain line from the drain valve and insert a ¾” MNPT Hex PVC plug (available at most hardware stores) to prevent preservative from leaking. Remove hose clamp on drain line and remove elbow. (Refer to Figure 1 for location of drain line on your System and Figure 2 for drain line parts.)

Photo 8. ¾” Plug in Automated

Drain Valve

4.Drain the pipes by disconnecting the outlet line on the side of the stainless steel flex hose furthest from the System. (Refer to Figure 1 for location of outlet line on your System and Figure 3 or 4 depending on your model for the outlet pipe assembly parts.) Drain into bucket for at least 10 minutes.

5.Close the outlet ball valve. (Refer to Photo 1 for location.) Plug the disconnected outlet line on the System side with a ¾” MNPT Hex PVC plug at the end of the Stainless Steel flexhose.

Photo 9. ¾” Plug in Stainless Steel

Flex Hose in Outlet Line

6.If using an External Prefilter, drain the External Prefilter Housing (refer to “Replacing the External Sediment Prefilter Cartridge” section), remove the External Prefilter Cartridge and discard the External Prefilter Cartridge. Replace the External Prefilter Housing without an External Prefilter Cartridge and close the stopcock on the bottom of the External Prefilter Housing.

7.Remove System Cap using the Cap Wrench.

8.Remove Stainless Steel Prefilter (Models MWF4200AWS and MWF4300AWS) or Carbon Prefilter (Model MWF4100AWS). If using a Carbon Prefilter, discard the Carbon Prefilter. If using a Stainless Steel

MAYTAG Whole Home Water Filtration System Owners Manual MA1-5

November 2003

28

Image 28
Contents Important see safety warnings and cautions inside Table of ContentsThank you… Dealer and System InformationUsing this Manual … Safety InstructionsOperational Safety Service and Maintenance SafetyOther Safety Precautions Winter StoragePhoto Certifications and Testing Models MWF4200AWS and MWF4300AWSModel MWF4100AWS Service Legal DisclaimerTrademarks Replacement Parts System DescriptionStartup of a new Maytag Whole Home Water Filtration System Maintenance ScheduleSanitizing Your Household Distribution System Model 41004200 Required service Comments Every 6 mo Every 12 Mo 4300MWF4300AWS Shut off water Drain the System for 1 minuteCleaning Remove the cap and internal prefilter from the SystemStainless Steel PrefilterRe-install Internal Model Cleaning Chemical UsedSoak 60 min Replacing the External Sediment Prefilter Cartridge Fill and Flush for 30 minStopcock Page Setting the Controller Base Controller Models MWF4100AWS and MWF4200AWSAdvanced Controller Model MWF4300AWS Choosing a Controller ProgramBase Controller Winterization Procedure Advanced ControllerNovember Drain line components for all models System Inlet line components for MWF4300AWS Before Winter Freeze-upNovember Spring startup and cleansing Prefilter November Cleaning the Stainless Steel Casing Annual Maintenance ChecklistFrequently Asked Questions Possible causes of low water pressure Problem Solution Does the System require electricity?Does the System affect the water pressure? What can be done to increase my water pressure?What happens if the power goes out? How long does the automatic cleaning cycle take?What are the maintenance requirements? How much water is used for flushing?Can it be shut down in winter? How long does the Carbon Prefilter last?What happens if there is a boil water alert in my area? November Troubleshooting Section Problem/Situation Correction/Action SystemSection Problem/Situation Correction/Action System 34/9 41/6Filtration System Warranty Schedule Suggested List Maytag Whole Home Water Filtration System Limited WarrantyPro-rated cost to the homeowner as a % November November