Maytag 2006 owner manual Operating Instructions, Controlling The Water, Electronic Indicator

Page 75

OPERATING INSTRUCTIONS

Controlling The Water

The PureTouch system has two options for water delivery, unfiltered stream and filtered water.

STREAM MODE: Unfiltered water in regular stream flow

When the water is turned on at the faucet, the spout will always begin operating in the regular stream mode.

FILTERED WATER MODE: Filtered water dispensed though the separate filtered water outlet.

Pressing the front filtered water button will divert water through the filter and dispense filtered water from a separate outlet. To exit the filter mode, shut off the faucet.

CAUTION: Only filter cold water. Do not filter water above 100 degrees F.

Electronic Indicator

The flashing light on the electronic filter life indicator provides information regarding the performance of the filter. The indicator provides you with information throughout the life of the filter to help communicate the level at which it is performing.

 

Plumbing

 

 

 

 

Indicate Color

Performance

 

 

 

 

 

A new filter must be flushed with cold water for 5 minutes

 

Amber & Green

after it is installed.

 

This procedure helps clean the filter of loose carbon

 

 

 

 

particles.

 

 

 

 

Green

Filter performing at optimum efficiency.

 

 

 

 

Amber

Warning: Filter is ready for replacement.

 

(Approximately 16 gallons left.)

 

 

 

 

 

 

Red

Warning: Filter life is deleted, discard old filter and replace

 

with a new Microtech 400 or 600 filter.

 

 

 

 

 

 

*If fast red doesn’t change to slow amber/green after memory has been reset, reset

F

was not complete and needs to be redone. Follow step 3 on the previous page.

 

A standard replaceable 3V lithium watch battery (2032) designed to last several years

 

powers the electronic indicator.

 

Battery Replacement

Follow filter replacement instructions to remove filter appliance. Locate battery compartment drawer, pull out and replace battery, positive side up.

CARE AND MAINTENANCE

All that is needed to clean your faucet is a soft damp cloth. Moen does not recommend the use of scour pads, cleansers or chemicals. The abrasive nature of these substances could damage the faucet’s finish. A non-abrasive car wax will help to protect the finish.

DO NOT SUBMERGE OR PLACE FAUCET HEAD IN DISHWASHER.

F - 16

Image 75
Contents Owners Airstream Manual Introduction MODEL Table of Contents Items Covered Warranty CoverageBasic Warranty Period Care and MaintenanceInstallations not Covered If Repairs are NeededAIRSTREAM, INC Consequential and Incidental Damages Warranty TransferExplanation of Airstream Limited Warranty Dealer Representation ExcludedAbuse ExposureOverload Reporting Safety Defects ServiceTorque aluminm wheels to110-120 ft. lbs Maintenance Schedule Every 5,000 Miles or 90 DaysThat MAY be Hazardous Every 1,000 Miles or 60 DaysEvery 10, 000 Miles or 6 Months Every Year Miscellaneous Suggested Maintenance Parts and LubricantsBULBS, Exterior BULBS, InteriorMaintenance Record Date Dealer Service Performed Warranty and Service TOW Vehicle Equipment Towing Your AirstreamElectric Brakes Loading Weighing Your Trailer Hitching UP Equalizing Hitch Load DistributionSway Control Device Steps for Hitching Up Level tow vehicle and trailer after hitching up Towing Tips Passing Use trailer brakes as parking brakes TrackingBacking Up Suggested PRE-TRAVEL Check List InteriorExterior Trailer Equipment and Accessories Motoring Essentials Towing Your Airstream Camping SafetyPlies the 12 volt current Overnight StopExtended Stay Things not to PUT Into Toilet or Drains Shoreline Power SupplyCity Water HOOK-UP Waste Water SystemEffects of Prolonged Occupancy Winter TravelingEffects of Prolonged Occupancy Tips to Controlling CondensationExcess moisture What are molds ? What factors contribute to mold growth?How can mold growth be inhibited? Failure to Retract Slide OUT RoomCamping Camping Exterior CleaningStep Main DoorPossible damage Screen DoorOperation Instructions ChassisTires Tips on Tire Care Tire Rotation Spare TireTire Inflation PSI Cold Axle and Running Gear Assembly Install washer and spindle nut Typical Electronic Controller HOW to USE Your Electric Brakes ProperlyPower Jack Option Replacing Power HeadMaintenance HOW Overloading Affects Your Tires Load/Inflation Information for Your TiresProper Tire Inflation Under InflationTire Care Weighing Your Travel Trailer Or Towed VehicleReplacing Your Tires Proper Inspection and Storage of TiresInterior Bunk BED Aquajet water pump Optionial Equipment Water Pump SwitchDinette Table Monitor PanelCeiling Light/Directional Lighting Bath Area Remote SwitchesSmoke Alarm Firex Model B LinoleumWeekly Testing of Your Smoke Alarm Replacing the Battery Taking Care of Your Smoke AlarmLP GAS Detector Using the Tamper Resist Locking MechanismSpecial Smoke Alarm Features To RemoveDetector Test LOW VoltageFire Extinguisher Normal Operation Carbon Monoxide AlarmCleaning Your Detector Operation only Fill ValveLPG Bottles To InstallVent if the trailer has not been used regularly Basic Rules for SafetyPlumbing Water SYSTEM-SELF Contained SanitizingWater Pump and Filter Drain Valves Safari While hooked to city water Aquajet Pump OptionalTo Empty Fresh Water Tank Water Heater DrainingWinterizing and Storage Plumbing Water Heater Bypass Plumbing Drain and Waste System DeodorizersEmptying Tanks Black Tank Flush Optional When Parked and Connected to Sewer OutletToilet Water Filtration Safeguards Microtech Filter INSTALLATION/REPLACEMENT Controlling The Water Electronic IndicatorBattery Replacement Operating InstructionsLavatory FAUCET, Standard Electrical System Battery Disconnect Switch265 71.3 F 250 62 F 200 16 F 100 +5 F 150 +19 F Battery12V Power Circuits Converter Cooling System Converter TestingConverter Operation Volt AC Panel BoardInvertor option Back UP Camera PRE-WIREElectrical System DO’S TV AntennaLubricating Rotating Gear Housing Maintenance LubricationSatellite Antenna Wiring Yellow like the sun positive and Green like Solar Panel PRE-WIREExternal Radio Jack Optional Coaxial Cable Wiring SchematicVolt Electrical System City Power Ground Fault Circuit Interrupter Gfci Occupant Other circuitFurnace AIR ConditionerMicrowave Ovens RangeRefrigerator Water Heater Electronic IgnitionRelieve the pressure without even realizing it Cleaning Instructions High Volume Roof Vent OptionalWhen Equipped with Reverse Switch When Equipped with ThermostatMonitor Panel Monitor Wire ConnectionsTo Obtain Exact Reading Specifications Hitch Ball Height Index C-1, E-8, F-3, H-4