5.Turn the pump switch OFF after all water has been removed from the storage tank.

6.Remove exhaust hose from water pump.

7.Disconnect the water pump inlet connection and turn the pump on until all the water is expelled. This water, about 1/2 cup, can be caught in a towel or rag.

8.Lower the front of the trailer as far as the jack will allow until water ceases to drain, then crank the jack up as high as it will go and let any remaining water drain out.

9.After the water has stopped running from the drain lines, apply at least 60 lbs, of air pressure at the city water inlet. An air to city water adapter is available from your dealer’s RV accessory store. Be sure the toilet valve and all drain valves and faucets are open and pump outlet hose is disconnected. This can be accomplished at a service station and will force any remaining water from the water heater and remove any water which may be trapped in low areas.

10.Pour a cup of *approved non-toxic RV antifreeze into the lavatory, sink and tub drains to prevent trap freeze-up.

*Approved and listed by a recognized testing authority such as UL (Underwriter Lab).

11.Be sure to open the waste holding tank drain valves and drain and flush the tanks thoroughly (THIS IS VERY IMPORTANT AS THE SEWAGE IN THE TANKS, IF FROZEN, COULD SERIOUSLY DAMAGE THE TANKS.)

12 Remove the cartridge of the water purifier and leave the purifier valve in the open position. (If so equipped.)

13.Remove the batteries from your trailer and store in a cool dry place where there is no danger of freezing. It is very important for optimum life of a battery to check it periodically and to keep it fully charged.

Plumbing

14.Remove any items (food, cosmetics, etc.) from trailer interior that might be dam- aged by freezing - or might damage the trailer if containers break.

For additional winterizing protection add a non-toxic antifreeze (approved for drinking water system) to the water lines using the following procedure.

1.Reconnect all lines except the hose to the pump inlet port. Close all drain valves.

2. Turn by-pass valve to by-pass position. To by-pass the water heater for winterizing,

close valves A and C and open valve B (See illustration on next page).

 

3. Attach a length of hose to the pump inlet port. This piece of hose should be long

 

enough for the free end to be inserted into and reach the bottom of the antifreeze

 

container.

F

4. Dilute the antifreeze solution in accordance with the manufacturer’s instructions

5.Open all water faucets.

6.Insert hose length into the antifreeze container, turn the pump switch on, and run the water pump until the antifreeze solution fills all water lines. Flush toilet. Work hand shower spray while holding down in tub.

7.Shut off the pump and close all faucets.

8.Disconnect the hose length from pump inlet fitting and reconnect water system inlet line.

F - 8

Image 67
Contents Owners Airstream Manual Introduction MODEL Table of Contents Items Covered Warranty CoverageBasic Warranty Period Care and MaintenanceIf Repairs are Needed Installations not CoveredAIRSTREAM, INC Consequential and Incidental Damages Warranty TransferExplanation of Airstream Limited Warranty Dealer Representation ExcludedExposure AbuseOverload Reporting Safety Defects ServiceTorque aluminm wheels to110-120 ft. lbs Maintenance Schedule Every 5,000 Miles or 90 DaysThat MAY be Hazardous Every 1,000 Miles or 60 DaysEvery 10, 000 Miles or 6 Months Every Year Miscellaneous Suggested Maintenance Parts and LubricantsBULBS, Exterior BULBS, InteriorMaintenance Record Date Dealer Service Performed Warranty and Service TOW Vehicle Equipment Towing Your AirstreamElectric Brakes Loading Weighing Your Trailer Equalizing Hitch Load Distribution Hitching UPSway Control Device Steps for Hitching Up Level tow vehicle and trailer after hitching up Towing Tips Passing Use trailer brakes as parking brakes TrackingBacking Up Interior Suggested PRE-TRAVEL Check ListExterior Trailer Equipment and Accessories Motoring Essentials Towing Your Airstream Camping SafetyPlies the 12 volt current Overnight StopExtended Stay Things not to PUT Into Toilet or Drains Shoreline Power SupplyCity Water HOOK-UP Waste Water SystemEffects of Prolonged Occupancy Winter TravelingTips to Controlling Condensation Effects of Prolonged OccupancyExcess moisture What factors contribute to mold growth? What are molds ?How can mold growth be inhibited? Failure to Retract Slide OUT RoomCamping Camping Exterior CleaningStep Main DoorPossible damage Screen DoorOperation Instructions ChassisTires Tips on Tire Care Spare Tire Tire RotationTire Inflation PSI Cold Axle and Running Gear Assembly Install washer and spindle nut Typical Electronic Controller HOW to USE Your Electric Brakes ProperlyReplacing Power Head Power Jack OptionMaintenance HOW Overloading Affects Your Tires Load/Inflation Information for Your TiresProper Tire Inflation Under InflationTire Care Weighing Your Travel Trailer Or Towed VehicleReplacing Your Tires Proper Inspection and Storage of TiresInterior Bunk BED Aquajet water pump Optionial Equipment Water Pump SwitchDinette Table Monitor PanelCeiling Light/Directional Lighting Bath Area Remote SwitchesSmoke Alarm Firex Model B LinoleumWeekly Testing of Your Smoke Alarm Replacing the Battery Taking Care of Your Smoke AlarmLP GAS Detector Using the Tamper Resist Locking MechanismSpecial Smoke Alarm Features To RemoveLOW Voltage Detector TestFire Extinguisher Normal Operation Carbon Monoxide AlarmCleaning Your Detector Operation only Fill ValveLPG Bottles To InstallVent if the trailer has not been used regularly Basic Rules for SafetyPlumbing Sanitizing Water SYSTEM-SELF ContainedWater Pump and Filter Drain Valves Safari While hooked to city water Aquajet Pump OptionalWater Heater Draining To Empty Fresh Water TankWinterizing and Storage Plumbing Water Heater Bypass Plumbing Deodorizers Drain and Waste SystemEmptying Tanks Black Tank Flush Optional When Parked and Connected to Sewer OutletToilet Water Filtration Safeguards Microtech Filter INSTALLATION/REPLACEMENT Controlling The Water Electronic IndicatorBattery Replacement Operating InstructionsLavatory FAUCET, Standard Electrical System Battery Disconnect Switch265 71.3 F 250 62 F 200 16 F 100 +5 F 150 +19 F Battery12V Power Circuits Converter Cooling System Converter TestingConverter Operation Volt AC Panel BoardInvertor option Back UP Camera PRE-WIREElectrical System DO’S TV AntennaLubricating Rotating Gear Housing Maintenance LubricationSatellite Antenna Wiring Yellow like the sun positive and Green like Solar Panel PRE-WIREExternal Radio Jack Optional Coaxial Cable Wiring SchematicVolt Electrical System City Power Ground Fault Circuit Interrupter Gfci Occupant Other circuitFurnace AIR ConditionerMicrowave Ovens RangeRefrigerator Electronic Ignition Water HeaterRelieve the pressure without even realizing it Cleaning Instructions High Volume Roof Vent OptionalWhen Equipped with Reverse Switch When Equipped with ThermostatMonitor Panel Monitor Wire ConnectionsTo Obtain Exact Reading Specifications Hitch Ball Height Index C-1, E-8, F-3, H-4