Pump Strainer Basket Service (Continued)

10.Ensure that the lid o-ring is properly placed. Seat the clamp and lid then turnclockwiseuntilthehandlesarehorizontalasshown.

11.Reconnectthecommunicationcabletothe pumpifrequired.

12.Switch the power ON at the circuit breaker. Reset the pool time clock to the correct time.

WARNING — FILTER OPERATES UNDER HIGH PRESSURE. WHEN ANY PART OF THE CIRCULATING SYSTEM (e.g., LOCK RING,

PUMP, FILTER, VALVES, ETC.) IS SERVICED, AIR CAN ENTER

THE SYSTEM AND BECOME PRESSURIZED. PRESSURIZED

AIR CAN CAUSE THE LID TO BLOW OFF WHICH CAN RESULT IN SEVERE INJURY, DEATH, OR PROPERTY DAMAGE. TO AVOID THIS POTENTIAL HAZARD, FOLLOW THESE INSTRUCTIONS.

Clamp

Lid

Volute

13.Open the manual air relief valve on top of the filter.

14.Stand clear of the filter. Press the Start button on the pump.

15.Bleed air from the filter until a steady stream of water comes out.

16.Closethemanualairreliefvalve.

Motor Service

1.Protect from heat:

Shade the motor and controller from the sun.

Any enclosure must be well ventilated to prevent overheating. Particular attention should be paid to the motor fan cover and the cooling fins between the drive and the motor.

Provideamplecrossventilation.

2.Protect against dirt:

Protect from any foreign matter or splashing water.

Do not store (or spill) pool chemicals near the motor.

Avoid sweeping or stirring up dust near the motor while it is operating.

If a motor has been damaged by dirt it voids the motor warranty.

3.Protect against moisture:

Protect from splashing pool water.

Protect from the weather.

Protectfromlawnsprinklers.

If a motor has become wet - let it dry before operating. Do not allow the pump to operate if it has been flooded.

If a motor has been damaged by water it voids the motor warranty.

Note: DO NOT wrap motor and controller with plastic or other air tight materials. The motor and controller may be covered, but not wrapped in plastic, during a storm, for winter storage, etc., but never when operating, or expecting operation.

When replacing the motor, be certain that the motor support is correctly positioned to support the size of motor being installed.

IntelliFlo VS-3050 Installation and User’s Guide

Image 24
Contents IntelliFlo VS-3050 Technical Support Phone 800 Fax 800 Protected by U.S. Patents PendingContents Important Safety Precautions Important NoticeImportant Safety Precautions General Installation Information General WarningsIntelliFlo VS-3050 Variable Speed Pump IntelliFlo VS-3050 modelsExternal Control IntelliFlo VS-3050 Motor Assembly FeaturesIntelliFlo VS-3050 Drive Assembly and Control Panel IntelliFlo VS-3050 Operator Control Panel Controls and LEDsSetting the pump preset speed Adjusting the pump speedResetting the pump to factory defaults Assigning a pump address for remote controlStarting the pump Stopping the pumpPriming the pump for the first time, or after service VoluteClamp External Control with IntelliComm Communication Center External ControlConnecting IntelliFlo VS-3050 to an EasyTouch System EasyTouch to IntelliFlo pin configuration Control panel Connecting IntelliFlo VS-3050 to an IntelliTouch System IntelliTouch Personality board COM Port J7/J8 Connecting IntelliFlo VS-3050 to a SunTouch System SunTouch MotherboardBlank Pump Strainer Basket Service Pump Strainer BasketMotor Service Clamp Lid VolutePriming the pump after service WinterizingBlank IntelliFlo VS-3050 Kit Contents Installing the IntelliFloLocation PipingWiring the IntelliFlo VS-3050 Pump Disassembly Pump Disassembly Pump Reassembly/Seal ReplacementShaft Seal Replacement Drive Assembly Removal and Installation Illustrated Parts List Replacement PartsIntelliFlo VS-3050 Electrical Specifications IntelliFlo VS-3050 Pump DimensionsIntelliflo VS-3050 Flow and Power vs Flow Pump Curve Blank Troubleshooting Alarm and warning LED sequenceGeneral IntelliFlo VS-3050 Troubleshooting Problems Problem Possible Cause Corrective ActionProblems and Corrective Action IntelliFlo VS-3050 Installation and User’s Guide Page 357269
Related manuals
Manual 16 pages 47.23 Kb

VS-3050 specifications

The Pentair VS-3050 is a highly efficient variable speed pool pump designed for residential swimming pools. With its advanced technology and user-friendly features, it provides an innovative solution for pool owners looking to optimize energy use and maintain crystal-clear water. Its capabilities not only reduce operational costs but also enhance the overall pool experience.

One of the standout features of the VS-3050 is its variable speed motor, which allows users to adjust the pump's speed according to their specific needs. This flexibility enables significant energy savings as the pump operates efficiently at lower speeds for routine tasks such as filtration, while higher speeds can be utilized for heavy-duty tasks like vacuuming or water feature operation. Compared to traditional single-speed pumps, the VS-3050 can reduce energy consumption by up to 90%, leading to lower electricity bills and a smaller carbon footprint.

The VS-3050 also boasts a user-friendly digital control interface, making it easy for pool owners to set schedules and adjust speed settings. The intuitive display guides users through programming, allowing them to create customized operation schedules that align with their habits and pool maintenance needs. Additionally, its ability to integrate with automation systems means users can control pump settings remotely, further enhancing convenience.

Durability is another key characteristic of the Pentair VS-3050. Built with robust materials, the pump is designed to withstand the rigors of outdoor conditions while providing reliable performance year after year. The pump features a quiet operation mode, making it a welcome addition to any backyard setting without disturbing the tranquility of outdoor relaxation.

Moreover, the VS-3050 is designed for ease of installation and maintenance. With a compact footprint and lightweight construction, it can easily fit into most existing setups without requiring extensive modifications. Maintenance tasks are simplified, encouraging pool owners to keep their systems running smoothly.

In summary, the Pentair VS-3050 is an exemplary variable speed pool pump that combines advanced technology, efficiency, and user convenience. Its energy-saving capabilities, easy-to-use control interface, durable construction, and low maintenance make it a top choice for pool owners seeking to enhance their pool experience. Embracing the VS-3050 means investing in a sustainable future for backyard leisure while ensuring the water remains clean, clear, and inviting.