IntelliFlo VS-3050 Kit Contents

IntelliFlo VS-3050 pump

Installing the IntelliFlo

Only a qualified service person should install the IntelliFlo pump.

Location

1.Install the pump as close to the pool or spa as possible. To reduce friction loss and improve efficiency, use short and direct suction and piping returns.

2.Install a minimum of five (5) feet from the inside wall of the pool and spa. Canadian installations require a minimum of three (3) meters from pool water.

3.Install the pump a minimum of two (2) feet from the heater outlet.

4.Do not install the pump more than (8) feet above the water level.

5.Install the pump in a sheltered well ventilated location protected from excessive moisture, (i.e., rain, sprinklers,etc.).

6.For hot tubs and spas, do not install within an outer enclosure or beneath the skirt of a hot tub or spa.

7.Install the pump with a rear clearance of at least 6 inches so that the motor can be removed easily for maintenanceandrepair.

Piping

For improved pool plumbing, it is recommended to use a larger pipe size. When installing the inlet and outlet fittings (male adaptors), use thread sealant. Do NOT use Teflon® tape.

Do not install 90° elbows directly into pump inlet or outlet.Avalve, elbow or tee installed in the suction line should be no closer to the front of the pump than five (5) times the suction line pipe diameter (i.e., two (2) inch pipe requires a ten (10) inch straight run in front of the suction inlet of the pump). This will help the pump prime faster and last longer.

Flooded suction systems should have gate valves installed on suction and discharge pipes for maintenance, however, the suction gate valve should be no closer than five (5) times the suction pipe diameter as described above.

Check Valve

Check valves must be used when the IntelliFlo is used in parallel with other pumps. IntelliFlo pumps cannot be used in series with other pumps.

IntelliFlo VS-3050 Installation and User’s Guide

Image 27
Contents IntelliFlo VS-3050 Phone 800 Fax 800 Protected by U.S. Patents Pending Technical SupportContents Important Notice Important Safety PrecautionsImportant Safety Precautions General Warnings General Installation InformationIntelliFlo VS-3050 Variable Speed Pump IntelliFlo VS-3050 modelsExternal Control Features IntelliFlo VS-3050 Motor AssemblyIntelliFlo VS-3050 Drive Assembly and Control Panel Controls and LEDs IntelliFlo VS-3050 Operator Control PanelAdjusting the pump speed Setting the pump preset speedStopping the pump Resetting the pump to factory defaultsAssigning a pump address for remote control Starting the pumpVolute Priming the pump for the first time, or after serviceClamp External Control External Control with IntelliComm Communication CenterConnecting IntelliFlo VS-3050 to an EasyTouch System EasyTouch to IntelliFlo pin configuration Control panel Connecting IntelliFlo VS-3050 to an IntelliTouch System IntelliTouch Personality board COM Port J7/J8 SunTouch Motherboard Connecting IntelliFlo VS-3050 to a SunTouch SystemBlank Pump Strainer Basket Pump Strainer Basket ServiceClamp Lid Volute Motor ServiceWinterizing Priming the pump after serviceBlank Piping IntelliFlo VS-3050 Kit ContentsInstalling the IntelliFlo LocationWiring the IntelliFlo VS-3050 Pump Disassembly Pump Disassembly Pump Reassembly/Seal ReplacementShaft Seal Replacement Drive Assembly Removal and Installation Replacement Parts Illustrated Parts ListIntelliFlo VS-3050 Electrical Specifications IntelliFlo VS-3050 Pump DimensionsIntelliflo VS-3050 Flow and Power vs Flow Pump Curve Blank Alarm and warning LED sequence TroubleshootingProblem Possible Cause Corrective Action General IntelliFlo VS-3050 Troubleshooting ProblemsProblems and Corrective Action IntelliFlo VS-3050 Installation and User’s Guide Page 357269
Related manuals
Manual 16 pages 47.23 Kb

VS-3050 specifications

The Pentair VS-3050 is a highly efficient variable speed pool pump designed for residential swimming pools. With its advanced technology and user-friendly features, it provides an innovative solution for pool owners looking to optimize energy use and maintain crystal-clear water. Its capabilities not only reduce operational costs but also enhance the overall pool experience.

One of the standout features of the VS-3050 is its variable speed motor, which allows users to adjust the pump's speed according to their specific needs. This flexibility enables significant energy savings as the pump operates efficiently at lower speeds for routine tasks such as filtration, while higher speeds can be utilized for heavy-duty tasks like vacuuming or water feature operation. Compared to traditional single-speed pumps, the VS-3050 can reduce energy consumption by up to 90%, leading to lower electricity bills and a smaller carbon footprint.

The VS-3050 also boasts a user-friendly digital control interface, making it easy for pool owners to set schedules and adjust speed settings. The intuitive display guides users through programming, allowing them to create customized operation schedules that align with their habits and pool maintenance needs. Additionally, its ability to integrate with automation systems means users can control pump settings remotely, further enhancing convenience.

Durability is another key characteristic of the Pentair VS-3050. Built with robust materials, the pump is designed to withstand the rigors of outdoor conditions while providing reliable performance year after year. The pump features a quiet operation mode, making it a welcome addition to any backyard setting without disturbing the tranquility of outdoor relaxation.

Moreover, the VS-3050 is designed for ease of installation and maintenance. With a compact footprint and lightweight construction, it can easily fit into most existing setups without requiring extensive modifications. Maintenance tasks are simplified, encouraging pool owners to keep their systems running smoothly.

In summary, the Pentair VS-3050 is an exemplary variable speed pool pump that combines advanced technology, efficiency, and user convenience. Its energy-saving capabilities, easy-to-use control interface, durable construction, and low maintenance make it a top choice for pool owners seeking to enhance their pool experience. Embracing the VS-3050 means investing in a sustainable future for backyard leisure while ensuring the water remains clean, clear, and inviting.