Pentair JSAYDL owner manual Installation, Ventilation, Piping, Spa Fittings

Page 4

INSTALLATION

Installation and wiring of pump should only be done by qualified, licensed personnel.

Pump mount must:

Be Solid - Level - Rigid - Vibration free. (To reduce vibration and pipe stress, bolt pump to mount.)

Be installed with pump suction inlet below water level at all times (this al- lows pump to prime).

Be installed with pump discharge below water level at all times (to avoid trapped air in discharge line).

Allow discharge line to be level or slope slightly up to heater, spa, or pool.

Have adequate drainage to prevent flooding.

Be protected from excess moisture.

Allow adequate access for servicing pump and piping.

Ventilation:

Provide adequate ventilation to prevent motor overheating.

For continuous running, motor hot air exhaust must be able to escape motor compartment.

Piping:

Use flexible or rigid PVC pipe for connections to pump.

Suction/discharge piping gate valves will allow removal for servicing.

Use at least 1-1/2" IPS pipe.

Fittings restrict flow; for best efficiency use fewest possible fittings.

Pump will not prime if suction pipe leaks.

Unions are provided. Use as follows for leak-free connections to pump:

1.‘O’ Ring and sealing surfaces must be clean.

2.Assemble handtight only! (NO WRENCHES!)

3.NO pipe compound or Teflon tape on unions.

4.Bond pipe to unions with PVC cement.

Use PVC cement only in a well ventilated area away from flame;

FOLLOW MANUFACTURER‘S INSTRUCTIONS!

Spa Fittings:

Size and number of jets will have a major effect on jet action.

Typical installations use up to four 7/8" or 3/4" diameter jets or up to seven 1/2" diameter jets.

Spa fittings must meet International Association of Plumbing and Mechanical Officials (IAPMO) standards. Use only non-entrapping suction fitting or double suction.

4

Image 4
Contents DURA-JETTMPUMP N E R ’ S M a N U a LTable of Contents DURA-JET SPA PumpRead and Follow ALL Instructions Installation VentilationPiping Spa FittingsElectrical WiringGrounding Remote Switching For 2-Speed Pumps VoltagePump Service OperationPriming Pump WaterInstalling New Seal Removing Old SealSTORAGE/WINTERIZING Torque SequenceDraining Pump Startup for Winterized EquipmentTroubleshooting Guide Pump does not OperateRepair Parts List Page Page Page S196