Pentair JSAYDL owner manual Troubleshooting Guide, Pump does not Operate

Page 11

TROUBLESHOOTING GUIDE

Read and understand safety and operating instructions in this manual before doing any work on pump!

A. PUMP DOES NOT OPERATE

1.Check GFCI for proper operation according to GFCI manufacturer’s in- structions.

2.Check for plugged impeller. Follow disassembly/assembly instructions under “Pump Service”, Page 8.

3.Consult dealer/installer or service representative.

B.IMPROPER JET ACTION

1.Check for blocked fittings. Blocked fittings will cause poor flow and poor jet action.

2.Consult dealer/installer or service representative.

C.EXCESSIVE AIR IN SYSTEM – PUMP LOSES PRIME

1.Make sure water level in spa is at least 2" (51 mm) above top of jets with system not operating.

2.Make sure there are no leaks in suction piping.

3.Make sure there is no vortex (whirlpool) at the suction.

4.Consult dealer/installer or service representative.

D.CIRCUIT BREAKER IN HOME PANEL TRIPS REPEATEDLY

1.Breaker must be of adequate capacity.

2.For GFCI breaker: test according to GFCI manufacturer’s instructions.

3.Make sure no other lights and appliances are on circuit.

4.Consult dealer/installer or service representative.

11

Image 11
Contents N E R ’ S M a N U a L DURA-JETTMPUMPDURA-JET SPA Pump Table of ContentsRead and Follow ALL Instructions Spa Fittings InstallationVentilation PipingGrounding WiringElectrical Voltage Remote Switching For 2-Speed PumpsWater Pump ServiceOperation Priming PumpRemoving Old Seal Installing New SealTorque Sequence STORAGE/WINTERIZINGStartup for Winterized Equipment Draining PumpPump does not Operate Troubleshooting GuideRepair Parts List Page Page Page S196