Multiquip QP2H manual Engine Safety, Fuel Safety, Before servicing equipment

Page 8

SAFETY INFORMATION

CAUTION

„NEVER lubricate components or attempt service on a running machine.

„NEVER block or restrict flow from discharge hose. Remove kinks from discharge line before starting pump. Operation with a blocked discharge line can cause water inside pump to overheat.

NOTICE

„ALWAYS fi ll the pump casing with water before starting the engine. Failure to maintain water inside the pump housing will cause severe damage to the pump and mechanical seal.

„In winter drain water from pump housing to prevent freezing.

„NEVER start the pump with the clean-out cover removed. The rotating impeller inside the pump can cut or sever objects caught in it. Before starting the pump, check that the clean-out cover is securely fastened.

„ALWAYS keep the machine in proper running condition.

„ALWAYS ensure pump is on level ground before use.

„Fix damage to machine and replace any broken parts immediately.

„ALWAYS store equipment properly when it is not being used. Equipment should be stored in a clean, dry location out of the reach of children and unauthorized personnel.

ENGINE SAFETY

WARNING

„NEVER operate the engine with heat shields or guards removed.

„ DO NOT remove the engine oil drain plug while the engine is hot. Hot oil will gush out of the oil tank and severely scald any persons in the general area of the pump.

CAUTION

„NEVER touch the hot exhaust manifold, muffl er or cylinder. Allow these parts to cool

before servicing equipment.

NOTICE

„NEVER run engine without an air fi lter or with a dirty air fi lter. Severe engine damage may occur. Service air fi lter frequently to prevent engine malfunction.

„NEVER tamper with the factory settings of the engine or engine governor. Damage to the engine or equipment can result if operating in speed ranges above the maximum allowable.

FUEL SAFETY

DANGER

„DO NOT add fuel to equipment if it is placed inside truck bed with plastic liner. Possibility exists of explosion or fi re due to static electricity.

„DO NOT start the engine near spilled fuel or combustible fl uids. Fuel is extremely fl ammable and its vapors can cause an explosion if ignited.

„ALWAYS refuel in a well-ventilated area, away from sparks and open fl ames.

„ALWAYS use extreme caution when working with flammable liquids.

„DO NOT fi ll the fuel tank while the engine is running or hot.

„DO NOT overfi ll tank, since spilled fuel could ignite if it comes into contact with hot engine parts or sparks from the ignition system.

PAGE 8 — QP2H CENTRIFUGAL PUMP • OPERATION AND PARTS MANUAL — REV. #1 (01/29/14)

Image 8
Contents Model QP2H This Manual Must Accompany the Equipment AT ALL TimesProposition 65 Warning Page Table of Contents QP2H Centrifugal PumpParts Ordering Procedures Ordering parts has never been easierSafety Information Safety MessagesGeneral Safety Pump Safety„ Never open the priming plug when pump Serious damage to the equipment or engineBefore servicing equipment Engine SafetyFuel Safety „ Use well-insulated gloves when picking up the battery Battery Safety Electric Start onlyTransporting Safety Emissions Information Label must remain with the engine for its entire lifeSpecifications Pump Specifications PumpDry Net Weight ModelSpecifications Engine Specifications EnginesDimension EngineGeneral Information Pump Components Drain Plug Remove this plug to drain water from the pumpMuffler Used to reduce noise and emissions Basic EngineInitial Servicing Inspection Engine Before StartingOil Type SeasonSetup Place the engine ON/OFF switch See in the on position OperationStarting the Engine Place the engine fuel valve lever See to the on positionPlace the fuel shut-off lever See in the OFF position Stopping the EngineAlways run engine at full speed while pumping Maintenance Pump Pump Vacuum TestDo not run pump without water Pump Vacuum TesterMaintenance Engine Engine MaintenanceEngine Maintenance Schedule First EveryEngine AIR Cleaner DailyWeekly Engine OILSpark Arrester Cleaning Spark Arrester RemovalStorage Pump StorageTroubleshooting Engine Engine TroubleshootingSymptom Possible Problem Solution Difficult to start Operation not satisfactorySymptom Possible Problem Solution Troubleshooting ENGINE/PUMPPump Troubleshooting Sample Parts List Explanation of Code in Remarks ColumnSuggested Spare Parts Qty DescriptionPump Assembly 7204100010 18893503510181050820 0191150520Engine Service Parts 17620Z4H020 28462ZH800317210ZE0822 17218ZE0505Terms and Conditions of Sale Parts Freight PolicyPage HERE’S HOW to GET Help
Related manuals
Manual 68 pages 41.17 Kb

QP2H specifications

The Multiquip QP2H is a high-performance portable generator designed to meet the power needs of both professionals and recreational users. Known for its reliability and robust design, this generator incorporates advanced technologies that ensure efficient operation, durability, and ease of use.

At the heart of the QP2H is its powerful Honda GX160 engine, which provides a maximum output of 2,000 watts. This engine is renowned for its fuel efficiency and low emissions, making it an environmentally friendly choice for users. The generator is equipped with a recoil start system that allows for easy ignition, even in challenging situations. Its lightweight and compact design make it highly portable, allowing users to transport it effortlessly to job sites, campsites, or outdoor events.

One of the standout features of the QP2H is its dual voltage capability. Users can switch between 120V and 240V output with a simple adjustment, making it versatile enough to power a variety of devices. This is particularly useful for contractors who need to run both standard tools and higher-voltage equipment. The generator also includes multiple AC outlets, providing flexibility for connecting multiple devices simultaneously.

Durability is a core characteristic of the QP2H. The generator's frame is built from strong steel, ensuring it can withstand the rigors of daily use in tough environments. It also features a protective roll cage that guards against impacts and enhances stability on uneven surfaces. The generator's design incorporates noise-reducing technology, which minimizes operational sound, making it more suitable for residential areas or noise-sensitive locations.

Another noteworthy aspect of the QP2H is its fuel tank capacity, which allows for extended run times. Users can expect up to 7 hours of continuous operation on a single tank, depending on the load. This efficiency is critical for users who need a reliable power source without the frequent interruptions of refueling.

In conclusion, the Multiquip QP2H stands out in the portable generator market due to its powerful engine, dual voltage capability, robust construction, and user-friendly design. Whether for construction sites, outdoor adventures, or emergency power backup, this generator provides the reliability and versatility needed to meet diverse power requirements. With the QP2H, users can rest assured knowing they have a dependable source of electricity wherever they go.