Johnson Controls R-410A NH/NJ-20 Upflow and Horizontal Airflow Performance, NH/NJ-20 Horizontal

Page 64

505430-BTG-A-0309

NH/NJ-20 Upflow and Horizontal Airflow Performance

NH/NJ-20 Upflow

J

 

 

 

 

 

 

Available External Static Pressure - IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CFM)

0.2

0.4

 

0.6

 

0.8

 

1.0

 

1.2

 

1.4

 

1.6

 

1.8

 

2.0

 

2.2

 

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

 

Std. 5

HP &

 

 

 

 

 

High Static 5 HP & Drive

 

 

 

 

 

 

High Static 7.5 HP & Drive

 

 

 

 

 

Field Supplied Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6000

 

 

 

 

 

732

 

2.2

789

 

2.6

846

 

2.9

900

 

3.1

959

 

4.0

1008

 

4.5

1056

 

4.9

1102

 

5.2

1146

 

5.3

6250

 

 

685

 

1.9

742

 

2.3

799

 

2.7

856

 

3.0

910

 

3.3

967

 

4.2

1016

 

4.7

1064

 

5.1

1110

 

5.4

1154

 

5.5

6500

 

 

696

 

2.1

752

 

2.5

809

 

2.8

866

 

3.2

920

 

3.4

976

 

4.4

1025

 

4.9

1072

 

5.3

1118

 

5.6

 

 

 

6750

 

 

706

 

2.2

763

 

2.6

820

 

3.0

877

 

3.3

935

 

4.0

985

 

4.6

1034

 

5.1

1081

 

5.5

1127

 

5.8

 

 

 

7000

 

 

718

 

2.4

774

 

2.8

831

 

3.2

888

 

3.5

945

 

4.2

994

 

4.8

1043

 

5.3

1091

 

5.7

1137

 

6.0

 

 

 

7250

 

 

729

 

2.6

786

 

3.0

843

 

3.3

900

 

3.6

954

 

4.5

1004

 

5.0

1053

 

5.5

1100

 

5.9

1146

 

6.2

 

 

 

7500

 

 

741

 

2.8

798

 

3.1

855

 

3.5

912

 

3.8

965

 

4.7

1014

 

5.3

1063

 

5.8

1111

 

6.2

 

 

 

 

 

 

7750

700

2.6

754

 

2.9

810

 

3.3

868

 

3.7

925

 

4.3

975

 

4.9

1025

 

5.5

1074

 

6.0

1121

 

6.4

 

 

 

 

 

 

8000

712

2.8

767

 

3.1

823

 

3.5

881

 

3.9

936

 

4.6

986

 

5.2

1036

 

5.8

1085

 

6.3

1132

 

6.7

 

 

 

 

 

 

8250

726

3.0

780

 

3.3

837

 

3.7

894

 

4.1

948

 

4.9

998

 

5.5

1047

 

6.0

1096

 

6.5

1144

 

6.9

 

 

 

 

 

 

8500

740

3.2

794

 

3.6

850

 

3.9

908

 

4.3

959

 

5.1

1010

 

5.8

1059

 

6.3

1108

 

6.8

 

 

 

 

 

 

 

 

 

8750

754

3.4

808

 

3.8

865

 

4.2

922

 

4.8

972

 

5.4

1022

 

6.0

1071

 

6.6

1120

 

7.1

 

 

 

 

 

 

 

 

 

9000

768

3.6

823

 

4.0

879

 

4.4

934

 

5.1

984

 

5.7

1034

 

6.4

1084

 

6.9

1133

 

7.4

 

 

 

 

 

 

 

 

 

9250

783

3.9

838

 

4.3

894

 

4.6

947

 

5.4

997

 

6.1

1047

 

6.7

1097

 

7.2

 

 

 

 

 

 

 

 

 

 

 

 

9500

799

4.1

853

 

4.5

910

 

4.9

961

 

5.8

1011

 

6.4

1061

 

7.0

1110

 

7.6

 

 

 

 

 

 

 

 

 

 

 

 

9750

815

4.4

869

 

4.8

925

 

5.5

974

 

6.1

1024

 

6.7

1074

 

7.3

1124

 

7.9

 

 

 

 

 

 

 

 

 

 

 

 

10000

831

4.7

885

 

5.0

939

 

5.9

988

 

6.5

1038

 

7.1

1088

 

7.7

1138

 

8.3

High Static 7.5 HP & Field Supplied Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Airflow performance includes dry evaporator coil. See Static Resistance table for additional applications.

2.See RPM Selection table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.746 ÷ nameplate rated motor efficiency.

NH/NJ-20 Horizontal

 

 

 

 

 

 

 

Available External Static Pressure - IWG

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

(CFM)

0.2

 

0.4

 

0.6

 

0.8

 

1.0

 

1.2

 

1.4

 

1.6

 

1.8

 

2.0

 

2.2

 

 

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

RPM

BHP

 

Std. 5

HP &

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Field

 

 

 

 

 

Standard 5 HP & Drive

 

 

 

 

 

 

 

High Static 7.5 HP & Drive

 

 

 

 

 

Supplied

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

6000

 

 

 

708

 

2.0

754

 

2.3

801

 

2.6

849

 

2.8

898

 

2.9

976

 

4.0

1021

 

4.4

1066

 

4.8

1111

 

5.1

1155

 

5.3

6250

 

 

 

715

 

2.1

761

 

2.4

808

 

2.7

856

 

2.9

906

 

3.0

984

 

4.2

1029

 

4.6

1074

 

5.0

1118

 

5.3

1163

 

5.5

6500

 

 

 

723

 

2.3

769

 

2.6

816

 

2.8

864

 

3.0

947

 

3.9

991

 

4.4

1036

 

4.8

1081

 

5.2

1126

 

5.4

 

 

 

6750

 

 

 

731

 

2.4

777

 

2.7

824

 

3.0

872

 

3.2

955

 

4.1

999

 

4.6

1044

 

5,0

1089

 

5.3

1134

 

5.6

 

 

 

7000

 

 

 

740

 

2.5

786

 

2.8

833

 

3.1

881

 

3.3

963

 

4.3

1007

 

4.7

1052

 

5.2

1097

 

5.5

1142

 

5.8

 

 

 

7250

 

 

 

749

 

2.7

796

 

3.0

842

 

3.3

890

 

3.5

971

 

4.5

1015

 

4.9

1060

 

5.3

1105

 

5.7

1150

 

6.0

 

 

 

7500

712

 

2.6

759

 

2.9

806

 

3.2

852

 

3.4

900

 

3.6

979

 

4.7

1024

 

5.1

1069

 

5.5

1114

 

5.9

1158

 

6.2

 

 

 

7750

722

 

2.8

770

 

3.0

816

 

3.3

863

 

3.6

945

 

4.4

988

 

4.9

1033

 

5.3

1078

 

5.8

1123

 

6.1

 

 

 

 

 

 

8000

733

 

2.9

781

 

3.2

827

 

3.5

874

 

3.8

954

 

4.6

998

 

5.1

1042

 

5.5

1087

 

6.0

1132

 

6.3

 

 

 

 

 

 

8250

745

 

3.1

793

 

3.4

839

 

3.7

886

 

4.0

964

 

4.8

1007

 

5.3

1052

 

5.8

1096

 

6.2

1141

 

6.5

 

 

 

 

 

 

8500

757

 

3.3

805

 

3.6

851

 

3.9

898

 

4.2

974

 

5.1

1017

 

5.6

1062

 

6.0

1107

 

6.4

1152

 

6.8

 

 

 

 

 

 

8750

770

 

3.6

818

 

3.8

864

 

4.1

942

 

4.8

984

 

5.3

1028

 

5.8

1072

 

6.3

1117

 

6.7

 

 

 

 

 

 

 

 

 

9000

784

 

3.8

831

 

4.1

878

 

4.4

953

 

5.1

995

 

5.6

1039

 

6.1

1083

 

6.5

1128

 

6.9

 

 

 

 

 

 

 

 

 

9250

798

 

4.0

845

 

4.3

923

 

4.9

964

 

5.4

1006

 

5.9

1050

 

6.3

1094

 

6.8

1139

 

7.2

 

 

 

 

 

 

 

 

 

9500

812

 

4.3

859

 

4.6

935

 

5.2

976

 

5.7

1018

 

6.2

1062

 

6.6

1106

 

7.1

1151

 

7.5

 

 

 

 

 

 

 

 

 

9750

827

 

4.5

908

 

5.1

947

 

5.5

988

 

6.0

1030

 

6.5

1074

 

6.9

1118

 

7.4

 

 

 

 

 

 

 

 

 

 

 

 

10000

842

 

4.8

921

 

5.4

960

 

5.8

1001

 

6.3

1043

 

6.8

1087

 

7.3

1131

 

7.7

High Static 7.5 HP & Field Supplied Drive

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1.Airflow performance includes dry evaporator coil. See Static Resistance table for additional applications.

2.See RPM Selection table to determine desired motor sheave setting and to determine the maximum continuous BHP.

3.kW = BHP x 0.746 ÷ nameplate rated motor efficiency.

64

Johnson Controls Unitary Products

Image 64
Contents Description Table of Contents C00 NomenclatureCondensing Unit Features and Benefits Outdoor Unit AccessoriesFeatures BenefitsAir Handling Unit Features and Benefits Unit InstallationAccessories Factory-Mounted ComponentsGuide Specifications Non-fused Disconnect Switch Refrigerant PipingElectrical Requirements Unit ControlsBlower Motor Shall Evaporator Coil ShallBlower Wheels Shall Physical Data YH-07 Thru -20 and YJ-10 Thru -20 Physical DataPH-07 Thru -20 and PJ-15 Thru -20 Physical Data Physical Data Indoor Unit Indoor CoilUnit Limitations Condenser Unit limitationsAir Handling Unit Limitations DB/WBCooling and Heating Ratings Cooling And Heating RatingCapacity Performance Condenser and Air Handling Cooling Capacities YH-07 / NH-07115F 125F YH-07 / NH-10 75FYH-07 / NH-10 YH-10 / NH-10 YH-10 / NH-10 YJ-10 / NJ-10 YJ-10 / NJ-10 YH-12 / NH-15 MBh YJ-12 / NJ-15 YJ-12 / NJ-15 YH-15 / NH-15 YH-15 / NH-15 YH-15 / NH-20 YH-15 / NH-20 YJ-15 / Two NH-07 YJ-15 / Two NH-07 YJ-15 / Two NH-10 Sensible Capacity MBhSensible Capacity MBh1 YJ-15 / NJ-15 115F 125F YJ-15 / NJ-20 Sensible Capacity MBh1 YH-20 / NH-20 115F 125F YJ-20 / Two NH-10 Total Sensible Capacity MBh1 YJ-20 / NJ-20 Capacity1 Input Condenser Only Cooling Capacities Condenser Only Ratings MBH EER75F 85F 115F 125F PH-10 / NH-10 PH-10 / NH-10 PH-15 / NH-15 PH-15 / NH-15 PJ-15 / NJ-15 PJ-15 / NJ-15 PH-20 / NH-20 PH-20 / NH-20 PJ-20 / NJ-20 PJ-20 / NJ-20 Heat Pump And Air Handler Heating Capacities PH-07 / NH-07 CFM68.2 80.0 93.8 84.3 98.8 Airflow Performance NH-07 Upflow and Horizontal Airflow PerformanceNH-07 Upflow NH-07 HorizontalNH/NJ-10 Upflow NH/NJ-10 Upflow and Horizontal Airflow PerformanceNH/NJ-10 Horizontal NH/NJ-15 Upflow NH/NJ-15 Upflow and Horizontal Airflow PerformanceNH/NJ-15 Horizontal NH/NJ-20 Upflow NH/NJ-20 Upflow and Horizontal Airflow PerformanceNH/NJ-20 Horizontal RPM Selection Additional Static Resistance BTG-A-0309 Altitude/Temperature Correction Factors Air Temperature ºFFactor CorrectionAirflow Performance Example Supply Air Blower PerformanceOutdoor Sound Power Levels dB, 60 Hz Sound PerformanceElectrical Data FLAAmpacity1 BTG-A-0309 Electrical Data For Indoor Models Electrical Data Indoor UnitsElectric Heat Option Electrical Data Indoor Units Typical YH-07 Wiring Diagram Typical Wiring DiagramsAir Conditioning Condensing Units Typical YH-10 / YH-12 Wiring Diagram Typical YJ-10 / YJ-12 Wiring Diagram Typical YH-15 / YH-20 Wiring Diagram Typical YJ-15 / YJ-20 Wiring Diagram Typical PH-07 Wiring Diagram Heat Pump UnitsTypical PH-10 Wiring Diagram Typical PH-15 / PH-20 Wiring Diagram Typical PJ-15 / PJ-20 Wiring Diagram Typical NH-07 Wiring Diagram Air Handling UnitsTypical NH/NJ-10 Thru NH/NJ-20 Wiring Diagram Weights And Dimensions Corner Weights & Center of Gravity AC/HP UnitsUnit Dimensions Unit Dimensions PH-07, PH-10, YH-07, YH/YJ-10, YH/YJ-12Unit Dimensions PH/PJ-15, PH/PJ-20, YH/YJ-15, YH/YJ-20 Location Dimensions Piping And Electrical Connection Sizes InchesCorner Weights & Center of Gravity NH/NJ Units LbsUnit Dimensions NH-07 / NH/NJ-10 and NJ-10 TOP ViewUnit Dimensions NH/NJ-15 Unit Dimensions NH/NJ-20 TOP ViewMinimum Clearances PIPING, Electrical and Duct Opening Connection SizesMounting Typical Suspension of AHU’s From CeilingTypical Field Wiring Diagram NH-07 Unit S1 G1 S2 G2 C Johnson Controls Unitary Products York Drive Norman, OK
Related manuals
Manual 16 pages 31.86 Kb

R-410A specifications

Johnson Controls R-410A is a widely recognized refrigerant in the HVAC industry, primarily used in air conditioning and heat pump applications. Known for its environmental benefits and efficiency, R-410A has risen to prominence as a reliable replacement for older refrigerants such as R-22, which are being phased out due to their harmful impact on the ozone layer.

One of the standout features of R-410A is its low impact on global warming potential, making it an environmentally-friendly choice. It is composed of a mixture of hydrofluorocarbons (HFCs), specifically difluoromethane (R-32) and pentafluoroethane (R-125). This blend allows for efficient heat transfer while minimizing harmful emissions, addressing the growing concerns over climate change.

Johnson Controls emphasizes the efficiency of R-410A systems, which can provide a highly effective cooling performance. They are designed to operate at higher pressures compared to R-22, allowing for more efficient heat exchange and better overall system performance. This results in greater energy efficiency ratings, contributing to lower electricity bills for consumers.

In terms of technology, R-410A systems often feature advanced compressor designs and enhanced coil configurations, which optimize the system’s performance. Johnson Controls integrates state-of-the-art variable speed technologies and smart controls that enhance responsiveness and adaptability to changing environmental conditions. These innovations not only improve thermal comfort but also reduce energy consumption, leading to a smaller carbon footprint.

Another significant characteristic of R-410A is its compatibility with various lubricants, which is crucial for maintaining system performance and longevity. Johnson Controls often utilizes specially formulated lubricants that work optimally with R-410A, ensuring reliable operation and reducing the risk of issues related to lubrication.

In summary, Johnson Controls R-410A is an important refrigerant characterized by its efficient, environmentally friendly properties and advanced technologies. Its application in modern HVAC systems provides users with excellent performance, substantial energy savings, and an effective solution for climate-conscious cooling. As the industry continues to evolve, R-410A remains a central player in the push toward more sustainable and efficient heating and cooling solutions.