GE 3200 installation instructions Read carefully, Replacing an Existing Unit?

Page 10

Installation Instructions

Read carefully

If you have any questions, call the GE Answer Center at 800.626.2000.

Replacing an Existing Unit?

Check the “Essential Elements” label for important information.

Use the correct wall case.

This chassis is designed to be installed in a GE plastic or insulated metal wall case. This mini- mizes condensation from forming on the room side of the case. If the current wall case is not insulated, you can reduce the possibility of condensation forming by installing insulation kit RAK901L, available where you purchased the chassis.

Use the correct outdoor grille.

You should use the outdoor grilles shown on the “Essential Elements” label on the top of the chassis.

If an existing grille is not replaced, capacity and efficiency will be reduced and the unit may fail to operate properly or fail prematurely. A deflector kit, RAK40, may be used with grilles that were not designed for your new GE Zonelines. The RAK40 contains air deflectors and gaskets that mount to the chassis to direct the hot exhaust air away from the air intake to allow the unit to function properly. The grille must have a 65% minimum free area.

Any vertical deflectors in the existing rear grille should be removed to decrease condenser air recirculation which can cause the unit to “short-cycle” and lead to premature compo- nent failure.

Replacing a ducted chassis.

New ducted installation—If this unit is to be installed in a new ducted application using a duct adaptor kit, the kit must be installed before the chassis is placed in the wall case. The installa- tion instructions are packed with the kit.

Mounting

Duct

plate

 

 

Case

Existing ducted installation—Replacement of an existing ducted unit may require different com- ponents. Request this information from your sales representative.

Replacing 230/208 volt units.

See page 12.

Replacing 265 volt units.

See page 13.

10

Image 10
Contents Zoneline 800.626.2000 Before using your ZonelineWrite down the model and serial Read ALL Safety Information Before Using Replacing an existing unit?Controls on your Zoneline Series onlyEnergy Tip Other Zoneline features To Remove the Room CabinetAuxiliary Controls Fan SwitchFreeze Sentinel Base Pan Care & CleaningOutdoor Coils Room Cabinet and CaseAir Filters Read carefully Replacing an Existing Unit?Zoneline Components Important Electrical Safety-Read CarefullyImportant Notes Do not use an extension cord with this unitHow to Connect 230/208 Volt Electrical SupplyVolt Electrical Supply Steps for preparing cordset for direct connectionConduit Remove the Shipping Tape from the Room Cabinet Install the Wall Case and the Exterior GrilleInsulated Wall Case Install the Unit into the Wall Case Replace the Room CabinetTemperature Limiting Low Voltage Connectors & Auxiliary ControlsElectric Heat Option-Model 3200 Series only Central Desk Control Load Shedding Remote Control/Wall Thermostat ClassAll-Time Low Fan Noise Things That Are NormalExplanation Zoneline Does Not Before You Call For ServiceProblem Possible Causes Cool or Heat as itBurning Odor at Start of Heating Operation Heating OperationPage Parts and Accessories Further ServiceOn-Site Repair Service We’ll be thereWhat Is Covered What Is Not Covered

3200 specifications

The GE 3200 is an advanced control system designed for a wide range of applications, primarily in the power generation sector, including gas and steam turbines. Known for its reliability and flexibility, the GE 3200 boasts several main features that set it apart from other control systems on the market.

One of the key characteristics of the GE 3200 is its modular architecture. This design allows for easy scalability and customization to cater to various operational needs. Whether a facility is operating a single turbine or a fleet of equipment, the system can be tailored to suit specific requirements, making it an ideal choice for both new installations and upgrades to existing plants.

The GE 3200 incorporates state-of-the-art technologies designed to enhance operational efficiency and safety. At the heart of the system is advanced digital signal processing capabilities, which enable real-time monitoring and control of equipment. This technology ensures that any deviation from normal operating parameters is quickly detected, allowing for immediate corrective action to be taken. This proactive approach helps minimize downtime and optimize performance.

Another significant feature of the GE 3200 is its user-friendly interface. The system is equipped with intuitive graphical displays that provide operators with vital information regarding the status of equipment and processes at a glance. This ease of use enhances operational efficiency by allowing staff to quickly assess system performance and respond to issues as they arise.

Moreover, the GE 3200 supports a variety of communication protocols, ensuring seamless integration with a range of devices and control systems. This interoperability is essential for modern power plants where multiple systems need to work together cohesively.

Security is also a top priority for the GE 3200. The system includes robust cybersecurity measures, protecting operational data from unauthorized access and cyber threats. This ongoing commitment to securing industrial control systems is critical in today's digital landscape.

In conclusion, the GE 3200 is a sophisticated control system that integrates advanced technologies with user-friendly features. Its modular design, real-time monitoring capabilities, and robust security measures make it an optimal solution for enhancing the efficiency and safety of power generation operations.