R

CB 1200 Pellet Stove

7Appliance Set-Up

A. Outside Air Kit Instructions

Included in Kit: 1 piece of 2 inch x 3 foot flex hose, 2 hose clamps, 1 collar assembly, termination cap assembly, 1 trim ring, 12 screws.

Tools Needed: Phillips head screw driver; wire cutters; hole saw or jig saw.

1.Rear Installation

2.Floor Installation

a.Remove rear screen and set aside.

b.Install cover plate over hole in right rear floor.

c.Cut a 2 inch minimum hole in the floor to accommodate flex hose.

d.Attach hose to termination cap.

e.Place rope under pedestal to close off air leaks.

a.Measure distance from floor to air vent opening in appli- ance and mark location on wall.

Use saw to cut opening in wall. Cut a 2-1/2 to 3 inch (64-76mm) opening on inside wall and a 3 to 3-1/2 inch

(76-89mm) opening on outside of house.

b.Use hose clamp to secure flex pipe to collar assembly.

c.Slide trim ring over flex pipe and run pipe through wall.

d.Attach hose to outside termination cap with second hose clamp.

e.Secure termination cap to outside surface.

f.Secure trim ring to interior wall.

g.Snip corners and remove plate. Figure 17.1.

Screen

Install Cover Plate

Seal Pedestal with 26 in. Rope

Figure 17.3

h.Align and secure collar assembly with 2 of the 4 holes as shown. Figure 17.2.

Snip Corners and remove plate

Figure 17.1

Secure Collar

NO

NO

Figure 17.2

CAUTION

Never draw outside combustion air from:

Wall, floor or ceiling cavity

Enclosed space such as an attic or garage

Termination

Cap Assembly

Hose Clamp

Trim Ring

Flex Hose

Hose Clamp

Collar Assembly

Figure 17.4

September 1, 2008

7014-082D

Page 17

Page 17
Image 17