R
CB 1200 Pellet Stove
C. Vertical
Rain Cap
Flashing | 24 in. (610mm) | |
| minimum | |
Firestop |
| |
| Class A Chimney | |
Ceiling Support | Connector Adapter | |
3 in. (76mm) | ||
| ||
6 in. | Min. | |
| ||
(152mm) | Top Vent Kit | |
Min. | ||
| ||
| ||
Cover | ||
|
We recommend a minimum of 60 in. (1524mm) vertical, however above the eave is preferred.
Both installations are approved for mobile home installations. Must use 3 or 4 inch (76 to 102mm) “L” or “PL” Listed pellet venting or listed double wall pipe and
Figure 14.1
D. Through The Wall & Vertical
| Rain Cap |
Flashing | 24 in. (610mm) |
| Minimum |
2 in. (51mm) Minimum | Support Bracket |
| |
| every 60 in. (1524mm) |
6 in. (152mm) |
|
Minimum | Wall Thimble |
| |
| Tee |
|
Figure 14.2
Page 14 | September 1, 2008 |