GE ASV14, ASV18 Through the Wall Installation Instructions-Optional, Finish the Wall Opening

Page 15

Through the Wall Installation Instructions–Optional.

The case may be installed through the wall in both existing and new construction.

Read completely, then follow step-by-step.

Safety

1 IMPORTANT

Through the wall installation is not appropriate if any of the side louvers in the case will be obstructed by the wall.

All side louvers in the case must project on the outdoor side of the wall.

The room side of the case must project into the room at least 134from the finished wall.

The case must be installed level from side-to-side and with a slight tilt from front to rear. Use a level; about a 1/2 bubble will be the correct case slant to the outside.

ARemove the air conditioner from the case. For specific instruction, refer to the Window Installation Instructions.

BMake certain a wall receptacle is available close to the hole location or make arrangements to install a receptacle.

CPlace the case in the wall opening and secure with 12 1″ long #10 wood screws.

NOTE: Drill pilot holes, if necessary, for proper installation. If the frame is oversized, use shims to prevent case distortion.

Instructions Operating Instructions Installation

2

Finish the Wall Opening

Caulk all four sides on the outdoor side of the case to prevent moisture from getting through to the

interior wall. Use of flashing (drip rail) will further prevent water from dripping inside the wall and

down the outside of the building.

 

Instructions

Lintel angle (if required)

Caulking

OUTSIDE

Air louvers (must project on the outdoor side of the wall.)

Wood Filler and Caulking

(above & below the flashing)

Flashing (Drip rail)

Plaster line

Trim molding (if desired)

INSIDE

Bottom rail

4.5 cm (13/4) min.

Troubleshooting Tips Consumer Support

15

Image 15
Contents Write the model and serial numbers here 49-7405 10-00 JRInstructions Operating Instructions Consumer Support Troubleshooting Tips InstallationUSE of Extension Cords -115-Volt models only Troubleshooting Tips Consumer SupportInstallation Instructions Remote ControlConsumer Air Direction Up and Down Cool ModeFAN Mode Vent ControlFor Normal Cooling-SelectHIGH Cool or MED Mode ControlsTemp Controls Cooling DescriptionsInstructions Operating Instructions TroubleshootingAir Direction Side-to-Side Air Direction Up and Down on some modelsCare and cleaning of the air conditioner Troubleshooting TipsInstallation Instructions Operating Read these instructions completely and carefully Preparing to install the air conditionerWindow Installation Instructions Remove the Front Grille, if attached Troubleshooting Tips ConsumerWindow Requirements Storm Window RequirementsPrepare the Window Operating InstructionsRemove the Air Conditioner From the Case Prepare the CaseInstall the Case in the Window Consumer Support Troubleshooting Install the Security Bracket and the Foam Top Window GasketInstall the Air Conditioner in the Case Through the Wall Installation Instructions-Optional Instructions Operating Instructions InstallationFinish the Wall Opening Before you call for service… Consumer SupportNormal Operating Sounds We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration We Will Replace Air Conditioner WarrantySafety Instructions Operating Instructions What Is Not CoveredReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website
Related manuals
Manual 20 pages 31.55 Kb

ASV14, ASV12, AST10, AST18, AST12 specifications

The GE ASM12, ASM16, AST12, ASM18, and ASP18 are state-of-the-art gas turbine systems designed to provide exceptional performance, reliability, and efficiency for power generation applications. These models reflect GE's commitment to innovation and technological advancement in the energy sector.

The ASM series, encompassing the ASM12, ASM16, and ASM18 models, is distinguished by its modular design and advanced aerodynamics. The ASM12 and ASM16, with their compact size, are ideal for a variety of installations, including peaking power plants and co-generation facilities. The ASM18, while slightly larger, boasts enhanced output and efficiency, making it suitable for base-load and intermediate-duty applications. Each model employs advanced materials that withstand high temperatures and pressures, resulting in improved performance and longevity.

The AST12 turbine is particularly noteworthy for its incorporation of integrated controls and advanced gas path technologies. This model emphasizes low emissions and high efficiency, utilizing advanced combustion systems that ensure cleaner operation. Its reliability and flexibility make it a preferred choice for operators seeking to optimize their power generation capabilities.

The ASP18 model stands out due to its ability to adapt to diverse fuel types, including natural gas and liquid fuels. This feature allows for greater operational flexibility and enables power plants to respond quickly to changes in energy demand. The ASP18 also features a robust digital control system that enhances monitoring and maintenance capabilities, ensuring optimal performance and reduced downtime.

All these models utilize GE's advanced digital twin technology, which provides operators with real-time monitoring and predictive analytics. This capability allows for proactive maintenance, reducing operational costs and extending the lifespan of turbine components.

In summary, the GE ASM12, ASM16, AST12, ASM18, and ASP18 turbines embody cutting-edge technology and design. They offer remarkable efficiency, reliability, and flexibility, making them suitable for a wide range of applications in the evolving energy landscape. With their emphasis on low emissions and adaptability to various fuel types, these turbines represent GE’s dedication to sustainable energy solutions and operational excellence in the global power generation industry.