GE ASP14, ASV18 Instructions Troubleshooting, Air Direction Side-to-Side, Instructions Operating

Page 7

www.GEAppliances.com

Additional controls and important information.

Safety

Energy Saver (on some models)

The energy saver switch controls the fan.

ON —The fan and compressor cycle on and off together. This results in wider variations of room temperature and humidity. Normally used when the room is unoccupied.

OFF — The fan runs all the time, while the compressor cycles on and off.

This switch must be set at OFF in order to use the fan settings (on the mode control).

Instructions Operating

Vent Control (on some models)

The vent control is located on the inside of the air louvers in the lower right corner.

When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open the vent, push the lever to the right.

To close it, push it to the left.

Instructions Installation

Air Direction – Side-to-Side

On some models, the side-to-side air direction is adjusted by the louver levers or by grasping and moving the inner vertical louvers .

OR

CIRCULAIRE (on some models)

For fixed side-to-side air direction, set the Circulaire switch to ON until the desired air direction is obtained, then move it to OFF.

For continuous side-to-side air circulation, set the Circulaire switch to ON and leave it there.

Instructions Troubleshooting

Air Direction – Up and Down (on some models)

Fingertip pressure on the horizontal louvers adjusts the air direction up or down.

OR

7

Tips Consumer Support

Image 7
Contents Write the model and serial numbers here 49-7405 10-00 JRInstructions Operating Instructions Consumer Support Troubleshooting Tips InstallationUSE of Extension Cords -115-Volt models only Troubleshooting Tips Consumer SupportRemote Control Installation InstructionsConsumer Air Direction Up and Down Cool ModeFAN Mode Vent ControlFor Normal Cooling-SelectHIGH Cool or MED Mode ControlsTemp Controls Cooling DescriptionsInstructions Operating Instructions TroubleshootingAir Direction Side-to-Side Air Direction Up and Down on some modelsTroubleshooting Tips Care and cleaning of the air conditionerInstallation Instructions Operating Read these instructions completely and carefully Preparing to install the air conditionerWindow Installation Instructions Remove the Front Grille, if attached Troubleshooting Tips ConsumerWindow Requirements Storm Window RequirementsPrepare the Window Operating InstructionsRemove the Air Conditioner From the Case Prepare the CaseInstall the Case in the Window Install the Security Bracket and the Foam Top Window Gasket Consumer Support TroubleshootingInstall the Air Conditioner in the Case Instructions Operating Instructions Installation Through the Wall Installation Instructions-OptionalFinish the Wall Opening Consumer Support Before you call for service…Normal Operating Sounds We’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration We Will Replace Air Conditioner WarrantySafety Instructions Operating Instructions What Is Not CoveredReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website
Related manuals
Manual 20 pages 31.55 Kb

ASV14, ASV12, AST10, AST18, AST12 specifications

The GE ASM12, ASM16, AST12, ASM18, and ASP18 are state-of-the-art gas turbine systems designed to provide exceptional performance, reliability, and efficiency for power generation applications. These models reflect GE's commitment to innovation and technological advancement in the energy sector.

The ASM series, encompassing the ASM12, ASM16, and ASM18 models, is distinguished by its modular design and advanced aerodynamics. The ASM12 and ASM16, with their compact size, are ideal for a variety of installations, including peaking power plants and co-generation facilities. The ASM18, while slightly larger, boasts enhanced output and efficiency, making it suitable for base-load and intermediate-duty applications. Each model employs advanced materials that withstand high temperatures and pressures, resulting in improved performance and longevity.

The AST12 turbine is particularly noteworthy for its incorporation of integrated controls and advanced gas path technologies. This model emphasizes low emissions and high efficiency, utilizing advanced combustion systems that ensure cleaner operation. Its reliability and flexibility make it a preferred choice for operators seeking to optimize their power generation capabilities.

The ASP18 model stands out due to its ability to adapt to diverse fuel types, including natural gas and liquid fuels. This feature allows for greater operational flexibility and enables power plants to respond quickly to changes in energy demand. The ASP18 also features a robust digital control system that enhances monitoring and maintenance capabilities, ensuring optimal performance and reduced downtime.

All these models utilize GE's advanced digital twin technology, which provides operators with real-time monitoring and predictive analytics. This capability allows for proactive maintenance, reducing operational costs and extending the lifespan of turbine components.

In summary, the GE ASM12, ASM16, AST12, ASM18, and ASP18 turbines embody cutting-edge technology and design. They offer remarkable efficiency, reliability, and flexibility, making them suitable for a wide range of applications in the evolving energy landscape. With their emphasis on low emissions and adaptability to various fuel types, these turbines represent GE’s dedication to sustainable energy solutions and operational excellence in the global power generation industry.