GE ASV10, ASM10*, ASM08*, ASQ12, ASQ10 Troubleshooting Tips Installation Instructions Operating

Page 6

Instructions Safety Instructions

About the controls on the air conditioner—models with control knob(s).

Features and appearance may vary.

Controls (on models so equipped)

Troubleshooting Tips Installation Instructions Operating

ON/OFF Switch

Turns air conditioner on and off.

NOTE: If the air conditioner is off and is then turned on while set in a Cool mode, it will take approximately 3 minutes for the compressor to start and cooling to begin.

Fan Switch (on some models)

Use to set the fan speed to LO or HI.

Mode/Temp Control

Use to set the air conditioner to the Fan Only or a Cool mode.

Fan Only Mode

Use Fan Only at HI or LO Fan to provide air circulation and filtering without cooling.

Cool Mode

Use a Cool setting with HI or LO Fan for cooling. Turn the knob clockwise, toward the larger blue area, for the indoor area to become cooler. Turn the knob counterclockwise, toward the smaller blue

Controls (on models so equipped)

area, for the indoor air to become warmer.

The Mode/Temp control is used to maintain the room temperature. When set in a Cool mode, the compressor will cycle on and off to keep the room at the same level of comfort.

Cooling Descriptions

For Normal Cooling—Select a Cool mode with the Mode/Temp knob set at the midpoint.

For Maximum Cooling—Select a Cool mode with the Mode/Temp knob set toward the larger blue area.

For Quieter & Nighttime Cooling—Select a Cool mode with the Mode/Temp knob set toward the smaller blue area.

NOTE: If you move the Mode/Temp control knob from a Cool setting to the Fan On setting, wait at least 3 minutes before switching back to a Cool setting.

Consumer Support

Mode Control

Hi Cool, Med Cool and Low Cool provide cooling with different fan speeds.

Low Fan or Hi Fan provides air circulation and filtering without cooling.

Thermostat Control

The thermostat control is used to maintain the room temperature. The compressor will cycle on and off to keep the room at the same level of comfort. When you turn the knob to a higher number, the indoor air will become cooler. Turn

6the knob to a lower number and the indoor air will become warmer.

NOTE: If you move the switch from a cool setting to OFF or

to a fan setting, wait at least 3 minutes before switching back to a cool setting.

Cooling Descriptions

For Normal Cooling–Select Hi Cool or Med Cool with the thermostat control at midpoint.

For Maximum Cooling–Select Hi Cool with the thermostat control at the highest number available on your knob.

For Quieter & Nighttime Cooling–Select Low Cool with the thermostat control at midpoint.

Image 6
Contents Air Conditioners Write the model and serial numbers here Model # Serial #Consumer Support Troubleshooting Tips Do not use an adapter plug with this applianceUSE of Extension CORDS-115-Volt models only Ge.comRemote Control ConsumerFan Mode Power Outage Recovery FeatureCool Mode Air Direction-Up and Down on some modelsTroubleshooting Tips Installation Instructions Operating Safety Instructions Air Direction-Side-to-SideGrille and Case Care and cleaning of the air conditionerHow to Insert the Batteries Outdoor CoilsBefore YOU Begin Electrical RequirementsTools YOU will Need Window Installation Instructions Parts IncludedWindow Requirements Storm Window RequirementsRemove the Front Grille if Attached Remove the AIR Conditioner from the Case Prepare the CaseInstall the Case Install the Security Bracket and the Foam TOP Window GasketInstall the Case in the Window Install the AIR Conditioner in the Case Through-the-Wall Installation Instructions-Optional Finish the Wall OpeningTroubleshooting Tips… Normal Operating SoundsWe’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration GE Air Conditioner Warranty What Is Not CoveredGE Will Replace Consumer Support GE Appliances Website Schedule ServiceParts and Accessories Real Life Design StudioAcondicionadores de Aire Seguridad Solucionar problemas Apoyo al consumidor ¡ADVERTENCIAControl remoto Las funciones y el aspecto pueden variarModo Cool Frio InstalaciónFunción de recuperación de pérdida de energía Modo de FAN VentiladorInterruptor de Fan Ventilador Control de Mode ModoInterruptor ON/OFF Control de Mode/Temp Modo/TempDirección del aire-de lado a lado Cuidado y limpieza del acondicionador de aire Precaución no Opere elSeguridad Antes DE Iniciar Requisitos ElectricosHerramientas QUE Usted Necesitará Partes IncluidasRequisitos Para LA Ventana Requisitos DE UNA Ventana DE TormentasRetire LA Parrilla Frontal SI Está Pegada Retire EL Acondicionador DE Aire DE LA CajaPrepare LA Caja Instale LA Caja EN LA VentanaInstale LA Caja Instale EL Acondicionador DE Aire EN LA CajaInstrucciones de instalación a través de la pared-opcional ImportanteTermine LA Abertura EN LA Pared ExteriorSolucionar problemas Sonidos de operación normales GE reemplazará Garantía de su acondicionador de aire de GEOperación Lo que no está cubiertoGarantías ampliadas Apoyo al Consumidor Página Web de GE AppliancesSolicite una reparación Piezas y accesorios

ASQ14, ASQ10, ASQ12, ASM08*, ASM10* specifications

The GE ASV10, ASM08*, ASQ14, ASQ12, and ASM10* are part of General Electric's advanced range of automation and control solutions designed for various industrial applications. These products are notable for their high performance, flexibility, and the ability to meet diverse operational requirements across several sectors.

The ASV10 is a versatile automation solution offering significant scalability options. It integrates seamlessly with multiple device types and supports various communication protocols, enabling users to create comprehensive control systems tailored to their specific needs. This feature facilitates easy integration into existing systems while allowing for future expansions.

ASM08*, on the other hand, is known for its rugged design and robust performance in challenging environments. It is equipped with advanced processing capabilities that enhance reliability in data management and real-time decision-making. The ASM08* supports a wide range of I/O configurations, making it an ideal choice for applications that require high adaptability.

Moving to the ASQ14 and ASQ12, these models are characterized by their sophisticated quality control features. They are designed to excel in environments where precision and reliability are paramount. These systems feature advanced data analytics, allowing operators to monitor processes in real-time and make informed decisions based on accurate information. The ASQ series also includes built-in diagnostic tools that facilitate troubleshooting and minimize downtime.

The ASM10* is another noteworthy addition, emphasizing high-speed processing and efficient energy management. This model supports cutting-edge technologies such as machine learning algorithms, allowing for predictive maintenance and enhanced operational efficiency. Its architecture is designed to optimize resource use, ensuring that users can maintain productivity while reducing operational costs.

In summary, the GE ASV10, ASM08*, ASQ14, ASQ12, and ASM10* showcase a commitment to innovation and excellence in automation technology. With features that cater to a wide array of industrial challenges — from scalability and integration to precision and efficiency — these products stand out as reliable solutions for modern automation needs. Together, they represent GE's dedication to advancing industry standards and providing tools that empower organizations to succeed in a competitive landscape.