GE AJHS10DCC installation instructions Temperature Limiting, Cleaning Installation

Page 9

ge.com

Fan Switch

To reach the fan switch(es) remove the front grille.

Safety Instructions

On Heat/Cool and Heat Pump models, the fan switch levers are located in holes accessed through the control box. The top switch is for COOL settings and the bottom switch is for HEAT settings.

Use a small screwdriver to change the setting. The unit is shipped from the factory set in the CONT setting for COOL and in the CYCLE setting for HEAT.

or

(Depending on model)

Operating

Cool only models have a rocker switch on the front of the control box.

When set at CYCLE (down) the fan cycles on and off when cooling. When set at CONT (continuous, up) the fan runs all the time, providing a more balanced temperature. The unit is shipped in the CONT setting.

Instructions Care and

Temperature Limiting

Limiting the maximum and minimum settings prevents users from turning the control to the extreme heat or cool positions.

The normal range of the temp control is approximately 60°F to 85°F. The control range may be narrowed by the use of the temperature limiting screws located behind the control panel.

Limits

Limits

heat

cool

temp

temp

Cleaning Installation

Each position equals approximately 3°F.

Vent Control

The vent control is located behind the front grille on the right side of the air discharge area. When set at CLOSE, only the air inside the room will be circulated and conditioned. When set at OPEN, some inside air is exhausted outside.

To open or close the vent:

1.Remove the front grille.

2.Remove the vent card screw.

3.Remove vent card, turn it over and replace it by locating rear hole in card over locating pin inside air discharge and reattaching screw at front.

The unit leaves the factory set at the CLOSE position.

Locating hole

Locating hole

Screw hole

Screw hole

OPEN position

CLOSE position

(Mesh end toward back)

(Mesh end toward front)

Instructions Troubleshooting Tips

Air Direction

Horizontal louvers

Remove the front

 

on the front grille

grille to adjust the

 

let you control the

vertical louvers

 

air direction up

side-to-side to

 

and down.

direct the air left

 

 

or right.

9

 

 

Consumer Support

Image 9
Contents Serial # Write the model and serial numbers hereContact a qualified service technician Troubleshooting Tips Consumer Support Cleaning Installation InstructionsOperating Instructions Ge.comInstructions Consumer Remote ControlFan Switch SafetyTroubleshooting Tips Air Direction Vent ControlDown Auxiliary Controls Temperature LimitingGe.com Cooling/Heating Descriptions Mode ControlHeat Pump Models Temp ControlTemperature Limiting Cleaning InstallationTo reach the fan switches remove the front grille Cleaning Operating Instructions Safety Instructions Care and cleaning of the air conditionerGrille and Case Outdoor CoilsAir Filter How to Insert the BatteriesBefore YOU Begin Electrical RequirementsModel Qualifying Questions GE KIT Numbers Tools YOU MAY NeedAttach Front Grille Installing a J-MODEL in AN Existing Wall CaseInstalling Through the Wall Prepare Opening in WallSupport Requirements for AIR Conditioner Window Requirements Window INSTALLATION-OPTIONALWood Pieces Width 2″ Storm Window RequirementsPrepare Window Install Sill SupportsRight Left MEASURE, CUT and Install Filler PanelsInstall Case in Window Replace AIR Conditioner in Case Install Window Gasket and Locking BracketNormal Operating Sounds Before you call for service…Air Conditioner Warranty GE Will ReplaceWhat GE Will Not Cover Parts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design StudioInstructions d’installation Manuel d’utilisation etGrille frontale Avertissement Et nettoyage Instructions de montage En cas de AvertissementTélécommande Commande d’évent Interrupteur du ventilateurEn cas de panne Soutien au Direction de l’air Commandes auxiliaires-Limitation de température Commande de la température Commande du modeModèles dotés de boutons de réglage Modèles avec pompe à chaleurLimitation de la température De sécuritéDirection de la sortie d’air Montage Entretien etGrille et boîtier Entretien et nettoyage du conditionneurSerpentins extérieurs Grille frontaleMise EN Garde Ne faites Filtre à airComment insérer les piles Exigences EN Matière ’ALIMENTATION Électrique Avant DE CommencerNuméros DE Trousses GE Outils Dont Vous Pouvez Avoir Besoin’AIDE D’UNE Agrafe Retirez LA Plaque DE Verrouillage SUR LE Côté Gauche AvantFixez LA Grille Frontale Glissez Délicatement LE Conditionneur Dans LE LogementInstallation À Travers LE MUR Préparation DE L’OUVERTURE Dans LE MURSupport DU Conditionneur Instructions Relatives À LA Fenêtre Installation DE Fenêtre EN OptionRetirez LE Conditionneur DE SON Logement Instructions Relatives À LA CONTRE-FENÊTREPréparez LA Fenêtre Installez LES Supports DE SeuilMESUREZ, Coupez ET Installez LES Panneaux DE Fermeture Montez LE Logement Dans LA Fenêtre Replacez LE Conditionneur Dans SON Logement Bruits normaux de fonctionnement En cas de panne Instructions de sécuritéEntretien et nettoyage Nous remplacerons Garantie du conditionneur d’airCe qui n’est pas couvert Et nettoyage Instructions de montage EnSoutien au consommateur Service de réparationsAcondicionador de aire Cuidado y limpieza Seguridad¡ADVERTENCIA Limpieza Instalación Solucionar problemasControl remoto Control remotoLimpieza Modo FAN Ventilador Interruptor del ventiladorControl del escape Dirección del aireDown Controles auxiliares-Limitación de temperaturaNotas Control de la temperatura Descripciones de enfriamientoModelos con bomba de calor Para calefacción máxima SeleccioneDependiendo Del modelo Límite de la temperaturaRejilla y caja Cuidado y limpieza del acondicionador de aireBobinas exteriores Rejilla delanteraPrecaución No opere el Filtro de aireCómo insertar las baterías Requisitos Eléctricos Antes DE IniciarNúmeros DE KIT DE GE Herramientas QUE Podría NecesitarUNA LA Rejilla Delantera Cómo Instalar UN Modelo J EN UNA Caja DE Pared ExistentePrepare LA Abertura DE LA Pared Cómo Instalar a Través DE LA ParedRequisitos Para EL Apoyo DEL Acondicionador DE Aire Requisitos DE Apoyo Para EL Acondicionador DE AireRequisitos Para LA Ventana Instalación DE VENTANA-OPCIONALRetire EL Acondicionador DE Aire DE LA Caja Requisitos DE Ventana Para TormentaInstale LOS Soportes DE LA Alfajía Exterior Prepare LA VentanaCentro MIDA, Corte E Instale LOS Paneles DE RellenoInstale LA Caja EN LA Ventana Reemplace EL Acondicionador DE Aire EN LA Caja Instale EL Empaque Para LA Ventana Y EL Soporte DE BloqueoAntes de llamar para solicitar servicio… Sonidos de operación normales Operación Seguridad Solucionar problemas Notas Garantía de su acondicionador de aire Solucionar problemas Apoyo al consumidorGE reemplazará Lo que no está cubiertoSolicite una reparación Apoyo al consumidor Página Web de GE AppliancesGarantías ampliadas Piezas y accesorios

AJHS10DCC specifications

The GE AJHS10DCC is a cutting-edge window air conditioning unit designed to provide efficient cooling solutions for residential spaces. With a compact design and a range of features, it is well-suited for both small and medium-sized rooms, ensuring comfort during the hot summer months.

One of the standout features of the GE AJHS10DCC is its cooling capacity. With a powerful 10,000 BTU rating, this unit can effectively cool spaces up to approximately 450 square feet, making it ideal for living rooms, bedrooms, or even office spaces. Additionally, the unit operates quietly, allowing users to enjoy a comfortable environment without disruptive noise levels.

The GE AJHS10DCC also incorporates a user-friendly digital thermostat with a remote control, providing convenience and flexibility. Users can easily adjust settings from a distance, which is particularly useful when relaxing on the couch or in bed. The programmable timer feature further enhances user experience, enabling the air conditioner to turn on or off at pre-set times, helping to save energy and reduce utility bills.

Energy efficiency is another key characteristic of the GE AJHS10DCC. It is ENERGY STAR certified, which means it meets strict energy efficiency guidelines set by the U.S. Environmental Protection Agency. This not only contributes to lower electricity bills but also aligns with eco-friendly practices, making it a responsible choice for consumers concerned about their environmental impact.

The unit features multiple cooling and fan speeds, along with an energy-saver mode. This allows users to customize their cooling experience based on personal preferences or room conditions. Additionally, the adjustable air vents enable better airflow distribution, ensuring that every corner of the room gets adequate cooling.

Installation of the GE AJHS10DCC is straightforward, thanks to the included mounting accessories. It's designed to fit most standard window sizes, and its lightweight construction makes it easy to handle. Moreover, the unit comes equipped with a washable filter, promoting cleaner indoor air quality by capturing dust and allergens, which can be easily maintained for optimal performance.

Overall, the GE AJHS10DCC combines powerful cooling capabilities with energy efficiency and user-friendly features, making it a top choice for anyone looking to enhance their indoor comfort during the warmer months.