GE AG_07 Troubleshooting Tips Consumer Support, Storm Window Requirements

Page 11

Read completely, then follow step-by-step.

1

Window Requirements

These instructions are for a standard double-

hung window. You will need to modify them for

other types of windows.

The air conditioner can be installed without the accordion panels if needed to fit in a narrow window. See the window opening dimensions below.

7,000, 8,000 and 10,000 BTU models

14min.

22to 36

(With accordion panels)

1834min.

(Without accordion panels)

All supporting parts must be secured to firm wood, masonry or metal.

The electrical outlet must be within reach of the power cord.

12,000 and 14,000 BTU models

16min.

27to 39

(With accordion panels)

2378min.

(Without accordion panels)

Safety Instructions Operating Instructions Installation Instructions

2

Storm Window Requirements

A storm window frame will not allow the air

conditioner to tilt towards the outside and will keep

 

it from draining properly. To adjust for this, attach

 

a piece of wood to the stool.

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Wood

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

1/2higher

 

 

 

 

 

 

 

 

 

 

 

 

 

 

than frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Stool

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Storm window

 

 

 

 

 

frame

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

WOOD PIECES—

WIDTH: 2″

LENGTH: Long enough to fit inside the window frame.

THICKNESS: To determine the thickness, place a piece of wood on the stool to make it 1/2″ higher than the top of the storm window frame.

Attach securely with nails or screws provided by the installer.

11

Troubleshooting Tips Consumer Support

Image 11
Contents Write the model and serial numbers here Model # Serial # Air ConditionersInstructions Operating Instructions Safety PrecautionsTips Consumer Support USE of Extension Cords -115-Volt models onlyConsumer Support Remote ControlAir Direction Side-to-Side Cool ModeFAN Mode Vent ControlConsumer Support InstallationInstructions Instructions Operating SafetyInstructions Troubleshooting Air Filter Care and cleaning of the air conditionerGrille and Case Outdoor CoilsRead these instructions completely and carefully Preparing to install the air conditionerOperating Instructions Parts Included Window Installation InstructionsStorm Window Requirements Troubleshooting Tips Consumer SupportWindow Requirements Prepare the Window and the Case Operating Instructions SafetyTroubleshooting Safety Instructions Operating Instructions Install the Case in the WindowInstall the Air Conditioner in the Case Operating Instructions Safety InstructionsBefore you call for service… Normal Operating Sounds Safety InstructionsWe’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration GE Will Replace Air Conditioner WarrantyInstallation Instructions Safety Instructions Operating InstructionsReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website

AG_07 specifications

The GE AG_07 is a sophisticated gas turbine designed to set new standards in energy efficiency and operational flexibility. This advanced turbine is part of GE's Aeroderivative Gas Turbine (AGT) family, which is well-known for its high performance and adaptability. With its innovative design and cutting-edge technologies, the AG_07 has become a cornerstone for power generation in diverse applications, including industrial, peaking, and renewables integration.

One of the key features of the GE AG_07 is its exceptional thermal efficiency. This turbine boasts a thermal efficiency of up to 39 percent in simple cycle and can achieve even higher efficiencies in combined cycle operations. This efficiency translates into lower fuel consumption and reduced greenhouse gas emissions, making it an environmentally friendly choice for power generation.

The AG_07 is also equipped with advanced aerodynamics and combustor technology. It incorporates a lean-premix combustion system that allows for stable combustion at a wide range of operating conditions. This system minimizes nitrogen oxide (NOx) emissions, adhering to stringent environmental regulations while also contributing to the turbine's overall efficiency. Moreover, the turbine utilizes advanced turbine cooling techniques to maintain optimal operating temperatures and enhance durability.

Another notable characteristic of the AG_07 is its compact and modular design. This design not only simplifies installation and maintenance but also enables the turbine to be easily integrated into existing power plants. It is particularly suited for applications that require quick ramp-up capabilities, making it an ideal choice for peaking power plants and backup generation systems.

In terms of technology, the AG_07 benefits from GE’s digital solutions. It is embedded with advanced sensors and predictive maintenance capabilities that allow operators to monitor performance in real time. This digital intelligence helps to optimize operations, reduce downtime, and extend the lifespan of the turbine.

Additionally, the GE AG_07 is designed to support a wide variety of fuels, from natural gas to biofuels, enhancing its flexibility in meeting different energy demands. This flexibility is crucial in today’s dynamic energy landscape, where the integration of renewable energy sources is becoming increasingly important.

Overall, the GE AG_07 gas turbine stands out for its high efficiency, low emissions, modular design, and advanced technologies. As energy needs continue to evolve, the AG_07 is well-positioned to meet the challenges of modern power generation while supporting a cleaner, more sustainable future.