GE AG_07 operating instructions Preparing to install the air conditioner, Operating Instructions

Page 9

Preparing to install the air conditioner.

Read these instructions completely and carefully.

Before You Begin

Safety Instructions

NOTE TO INSTALLER: Leave these instructions with the air conditioner after installation is completed.

NOTE TO CONSUMER: Keep this Owner’s Manual and Installation Instructions for future use.

IMPORTANT NOTES:

For personal safety, this air conditioner must be properly grounded.

It is important to have the wall outlet and circuit checked by a qualified electrician if there is any doubt as to whether a proper ground exists.

Follow National Electric Codes (NEC) and/or local codes and ordinances.

CAUTION:

Do not, under any circumstances, cut or remove the third (ground) prong from the power cord.

Do not change the plug on the power cord of this air conditioner.

Aluminum house wiring may present special problems—consult a qualified electrician.

Operating Instructions

Electrical Requirements

Some models require 115/120-volt a.c., 60 Hz grounded outlet protected with

a 15-amp time delay fuse or circuit breaker.

The 3-prong grounding plug minimizes the possibility of electric shock hazard. If the wall outlet you plan to use is only a 2-prong outlet, it is your responsibility to have it replaced with a properly grounded 3-prong wall outlet.

Some models require 230/208-volt a.c., protected with a time delay fuse or circuit breaker. These models should be installed on their own single branch circuit for best performance and to prevent overloading house or apartment wiring circuits, which could cause a possible fire hazard from overheating wires.

Tools You Will Need

Phillips-head screwdriver

Scissors or knife

Flat-blade screwdriver

Pencil

Ruler or tape measure

Level

9

Installation Instructions Troubleshooting Tips Consumer Support

Image 9
Contents Write the model and serial numbers here Model # Serial # Air ConditionersInstructions Operating Instructions Safety PrecautionsTips Consumer Support USE of Extension Cords -115-Volt models onlyConsumer Support Remote ControlFAN Mode Cool ModeVent Control Air Direction Side-to-SideInstallation InstructionsConsumer Support Safety Instructions TroubleshootingInstructions Operating Grille and Case Care and cleaning of the air conditionerOutdoor Coils Air FilterPreparing to install the air conditioner Operating InstructionsRead these instructions completely and carefully Parts Included Window Installation InstructionsTroubleshooting Tips Consumer Support Window RequirementsStorm Window Requirements Operating Instructions Safety TroubleshootingPrepare the Window and the Case Safety Instructions Operating Instructions Install the Case in the WindowInstall the Air Conditioner in the Case Operating Instructions Safety InstructionsBefore you call for service… Normal Operating Sounds Safety InstructionsWe’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Installation Instructions Air Conditioner WarrantySafety Instructions Operating Instructions GE Will ReplaceParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio

AG_07 specifications

The GE AG_07 is a sophisticated gas turbine designed to set new standards in energy efficiency and operational flexibility. This advanced turbine is part of GE's Aeroderivative Gas Turbine (AGT) family, which is well-known for its high performance and adaptability. With its innovative design and cutting-edge technologies, the AG_07 has become a cornerstone for power generation in diverse applications, including industrial, peaking, and renewables integration.

One of the key features of the GE AG_07 is its exceptional thermal efficiency. This turbine boasts a thermal efficiency of up to 39 percent in simple cycle and can achieve even higher efficiencies in combined cycle operations. This efficiency translates into lower fuel consumption and reduced greenhouse gas emissions, making it an environmentally friendly choice for power generation.

The AG_07 is also equipped with advanced aerodynamics and combustor technology. It incorporates a lean-premix combustion system that allows for stable combustion at a wide range of operating conditions. This system minimizes nitrogen oxide (NOx) emissions, adhering to stringent environmental regulations while also contributing to the turbine's overall efficiency. Moreover, the turbine utilizes advanced turbine cooling techniques to maintain optimal operating temperatures and enhance durability.

Another notable characteristic of the AG_07 is its compact and modular design. This design not only simplifies installation and maintenance but also enables the turbine to be easily integrated into existing power plants. It is particularly suited for applications that require quick ramp-up capabilities, making it an ideal choice for peaking power plants and backup generation systems.

In terms of technology, the AG_07 benefits from GE’s digital solutions. It is embedded with advanced sensors and predictive maintenance capabilities that allow operators to monitor performance in real time. This digital intelligence helps to optimize operations, reduce downtime, and extend the lifespan of the turbine.

Additionally, the GE AG_07 is designed to support a wide variety of fuels, from natural gas to biofuels, enhancing its flexibility in meeting different energy demands. This flexibility is crucial in today’s dynamic energy landscape, where the integration of renewable energy sources is becoming increasingly important.

Overall, the GE AG_07 gas turbine stands out for its high efficiency, low emissions, modular design, and advanced technologies. As energy needs continue to evolve, the AG_07 is well-positioned to meet the challenges of modern power generation while supporting a cleaner, more sustainable future.