Problem

 

Possible Causes

What To Do

 

 

 

 

Air conditioner

 

The air conditioner

Make sure the air conditioner plug is pushed completely

does not start

 

is unplugged.

into the outlet.

 

 

 

 

 

 

The fuse is blown/circuit

Check the house fuse/circuit breaker box and replace

 

 

breaker is tripped.

the fuse or reset the breaker.

 

 

 

 

 

 

Power failure.

If power failure occurs, turn the air conditioner OFF.

 

 

 

When power is restored, wait 3 minutes to restart the

 

 

 

air conditioner to prevent tripping of the compressor

 

 

 

overload.

 

 

 

 

Air conditioner does not

 

Airflow is restricted.

Make sure there are no curtains, blinds or furniture

cool as it should

 

 

blocking the front of the air conditioner.

 

 

 

 

 

 

The temp control may not

On models with touch pads: In COOL mode, press the

 

 

be set correctly.

DECREASE pad.

 

 

 

On models with control knobs, turn the temperature

 

 

 

knob to a higher number.

 

 

 

 

 

 

The air filter is dirty.

Clean the filter at least every 30 days.

 

 

 

See the Operating Instructions section.

 

 

 

 

 

 

The room may have been hot.

When the air conditioner is first turned on you need to

 

 

 

allow time for the room to cool down.

 

 

 

 

 

 

Cold air is escaping.

Check for open furnace floor registers and cold air returns.

 

 

 

Set the air conditioner’s vent to the closed position.

 

 

 

 

 

 

Cooling coils have iced up.

See “Air conditioner freezing up” below.

 

 

 

 

Air conditioner

 

Ice blocks the air flow and

On models with control knobs, set the mode control at

freezing up

 

stops the air conditioner

HIGH FAN or HIGH COOL with the temp at 1 or 2.

 

 

from cooling the room.

On models with touch pads, set the controls at

 

 

 

 

 

 

HIGH (F3) FAN or HIGH (F3) COOL and set the thermostat

 

 

 

to a higher temperature.

 

 

 

 

The remote control

 

The batteries are inserted

Check the position of the batteries. They should be

is not working

 

incorrectly.

inserted in the opposite (+) and (–) direction.

 

 

 

 

 

 

The batteries may be dead.

Replace the batteries.

Water drips outside

 

Excessively hot and

This is normal.

 

 

humid weather.

 

 

 

 

 

Water drips indoors

 

The air conditioner is not

For proper water disposal, make sure the air conditioner

 

 

tilted to the outside.

slants slightly from the case front to the rear.

 

 

 

 

Water collects in

 

Moisture is removed from

This is normal for a short period in areas with little

base pan

 

indoor air and drains into

humidity; normal for a longer period in very humid areas.

 

 

rear of a cabinet where a fan

 

 

 

blows it against the outdoor

 

 

 

condenser coil.

 

15

Safety Instructions Operating Instructions Installation Instructions Troubleshooting Tips Consumer Support

Image 15
Contents Write the model and serial numbers here Model # Serial # Air ConditionersInstructions Operating Instructions Safety PrecautionsTips Consumer Support USE of Extension Cords -115-Volt models onlyConsumer Support Remote ControlAir Direction Side-to-Side Cool ModeFAN Mode Vent ControlInstallation InstructionsConsumer Support Safety Instructions TroubleshootingInstructions Operating Air Filter Care and cleaning of the air conditionerGrille and Case Outdoor CoilsPreparing to install the air conditioner Operating InstructionsRead these instructions completely and carefully Parts Included Window Installation InstructionsTroubleshooting Tips Consumer Support Window RequirementsStorm Window Requirements Operating Instructions Safety TroubleshootingPrepare the Window and the Case Safety Instructions Operating Instructions Install the Case in the WindowInstall the Air Conditioner in the Case Operating Instructions Safety InstructionsBefore you call for service… Normal Operating Sounds Safety InstructionsWe’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration GE Will Replace Air Conditioner WarrantyInstallation Instructions Safety Instructions Operating InstructionsReal Life Design Studio Schedule ServiceParts and Accessories Consumer Support GE Appliances Website

AG_07 specifications

The GE AG_07 is a sophisticated gas turbine designed to set new standards in energy efficiency and operational flexibility. This advanced turbine is part of GE's Aeroderivative Gas Turbine (AGT) family, which is well-known for its high performance and adaptability. With its innovative design and cutting-edge technologies, the AG_07 has become a cornerstone for power generation in diverse applications, including industrial, peaking, and renewables integration.

One of the key features of the GE AG_07 is its exceptional thermal efficiency. This turbine boasts a thermal efficiency of up to 39 percent in simple cycle and can achieve even higher efficiencies in combined cycle operations. This efficiency translates into lower fuel consumption and reduced greenhouse gas emissions, making it an environmentally friendly choice for power generation.

The AG_07 is also equipped with advanced aerodynamics and combustor technology. It incorporates a lean-premix combustion system that allows for stable combustion at a wide range of operating conditions. This system minimizes nitrogen oxide (NOx) emissions, adhering to stringent environmental regulations while also contributing to the turbine's overall efficiency. Moreover, the turbine utilizes advanced turbine cooling techniques to maintain optimal operating temperatures and enhance durability.

Another notable characteristic of the AG_07 is its compact and modular design. This design not only simplifies installation and maintenance but also enables the turbine to be easily integrated into existing power plants. It is particularly suited for applications that require quick ramp-up capabilities, making it an ideal choice for peaking power plants and backup generation systems.

In terms of technology, the AG_07 benefits from GE’s digital solutions. It is embedded with advanced sensors and predictive maintenance capabilities that allow operators to monitor performance in real time. This digital intelligence helps to optimize operations, reduce downtime, and extend the lifespan of the turbine.

Additionally, the GE AG_07 is designed to support a wide variety of fuels, from natural gas to biofuels, enhancing its flexibility in meeting different energy demands. This flexibility is crucial in today’s dynamic energy landscape, where the integration of renewable energy sources is becoming increasingly important.