GE AG_07 Install the Case in the Window, Safety Instructions Operating Instructions

Page 13

Install the Case in the Window

5

 

Open the window and mark the centerline of

A

the window stool.

 

 

 

Carefully place the case on the window stool

 

B

 

 

and align the center mark on the bottom front

 

 

 

 

with the centerline of the stool.

 

 

Pull the window down behind the top

 

C

 

 

mounting rail.

 

 

FAdjust the bolt and the nut in each support so that the case is installed with a slight tilt to the outside. Use a level; about 1/3 bubble will be the correct case slant to the outside.

GSecure the case to the window stool by using 3 type B screws.

Safety Instructions Operating Instructions

NOTE: Do not shut the window so tightly that movement of the accordion panels is restricted.

DLoosely assemble the sill supports.

INDOOR

OUTDOOR

Sill support

Bolt Nut

ESelect the position that will place the sill supports near the outermost point on the sill. Attach the sill supports to the case track hole in relation to the selected position using 2 type A screws in each support.

Frame guide

Sill support

HPull the accordion panels to each window sash track. Attach them on each side to the window sash and the window stool using 4 type C screws.

Installation Instructions Troubleshooting Tips Consumer Support

13

Image 13
Contents Write the model and serial numbers here Model # Serial # Air ConditionersInstructions Operating Instructions Safety PrecautionsTips Consumer Support USE of Extension Cords -115-Volt models onlyConsumer Support Remote ControlFAN Mode Cool ModeVent Control Air Direction Side-to-SideInstructions InstallationConsumer Support Instructions Troubleshooting SafetyInstructions Operating Grille and Case Care and cleaning of the air conditionerOutdoor Coils Air FilterOperating Instructions Preparing to install the air conditionerRead these instructions completely and carefully Parts Included Window Installation InstructionsWindow Requirements Troubleshooting Tips Consumer SupportStorm Window Requirements Troubleshooting Operating Instructions SafetyPrepare the Window and the Case Safety Instructions Operating Instructions Install the Case in the WindowInstall the Air Conditioner in the Case Operating Instructions Safety InstructionsBefore you call for service… Normal Operating Sounds Safety InstructionsWe’ll Cover Any Appliance. Anywhere. Anytime Consumer Product Ownership Registration Installation Instructions Air Conditioner WarrantySafety Instructions Operating Instructions GE Will ReplaceParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio

AG_07 specifications

The GE AG_07 is a sophisticated gas turbine designed to set new standards in energy efficiency and operational flexibility. This advanced turbine is part of GE's Aeroderivative Gas Turbine (AGT) family, which is well-known for its high performance and adaptability. With its innovative design and cutting-edge technologies, the AG_07 has become a cornerstone for power generation in diverse applications, including industrial, peaking, and renewables integration.

One of the key features of the GE AG_07 is its exceptional thermal efficiency. This turbine boasts a thermal efficiency of up to 39 percent in simple cycle and can achieve even higher efficiencies in combined cycle operations. This efficiency translates into lower fuel consumption and reduced greenhouse gas emissions, making it an environmentally friendly choice for power generation.

The AG_07 is also equipped with advanced aerodynamics and combustor technology. It incorporates a lean-premix combustion system that allows for stable combustion at a wide range of operating conditions. This system minimizes nitrogen oxide (NOx) emissions, adhering to stringent environmental regulations while also contributing to the turbine's overall efficiency. Moreover, the turbine utilizes advanced turbine cooling techniques to maintain optimal operating temperatures and enhance durability.

Another notable characteristic of the AG_07 is its compact and modular design. This design not only simplifies installation and maintenance but also enables the turbine to be easily integrated into existing power plants. It is particularly suited for applications that require quick ramp-up capabilities, making it an ideal choice for peaking power plants and backup generation systems.

In terms of technology, the AG_07 benefits from GE’s digital solutions. It is embedded with advanced sensors and predictive maintenance capabilities that allow operators to monitor performance in real time. This digital intelligence helps to optimize operations, reduce downtime, and extend the lifespan of the turbine.

Additionally, the GE AG_07 is designed to support a wide variety of fuels, from natural gas to biofuels, enhancing its flexibility in meeting different energy demands. This flexibility is crucial in today’s dynamic energy landscape, where the integration of renewable energy sources is becoming increasingly important.

Overall, the GE AG_07 gas turbine stands out for its high efficiency, low emissions, modular design, and advanced technologies. As energy needs continue to evolve, the AG_07 is well-positioned to meet the challenges of modern power generation while supporting a cleaner, more sustainable future.