GE 2900, 3900 230/208 Volt Electrical Connection Options HOW to Connect, Power Cord Connection

Page 13

Installation Instructions

230/208 VOLT ELECTRICAL CONNECTION OPTIONS

HOW TO CONNECT

1Remove the room cabinet.

2Connect to electrical power.

3Review the following steps for applicable supply voltages.

4Reinstall the room cabinet.

Power cords may include an arc fault interruption or a leakage current detection interruption device. A test and reset button is provided on the plug case or the inline case. The device should be tested on a periodic basis by first pressing the TEST button and then the RESET button. If the TEST button does not trip or if the RESET button will not stay engaged, discontinue use of the Zoneline and contact a qualified service technician.

POWER CORD

CONNECTION

A power supply kit must be used to supply power to the Zoneline unit. The appropriate kit is determined by the voltage, the means of electrical connection and the amperage of the branch circuit.

Power supply kit

Connections of 208 or 230-volt circuits may be with a power supply kit or a junction box kit.

All wiring, including installation of the receptacle, must be in accordance with the NEC and local codes, ordinances and regulations. Local codes may require the use of an arc fault or leakage current detection device on the power cord. Be sure to select the correct cord for your installation.

Tandem

Perpendicular

Large Tandem

15 Amp.

20 Amp.

 

30 Amp.

230/208-volt receptacle configuration.

 

 

 

 

Branch Circuit and

 

Proper GE Power Cord

Unit Amperage Rating

 

 

with LCDI Device

 

 

 

 

 

 

 

15

 

 

RAK3153

 

 

 

 

 

 

 

20

 

 

RAK3203

 

 

 

 

 

 

 

30

 

 

RAK3303*

 

 

 

 

 

 

*Not approved for use on 7000 BTU models.

ELECTRICAL SUBBASE CONNECTION

230/208-volt models may be installed using one of the following electrical subbases:

Branch Circuit and

Proper GE

Unit Amperage Rating

Subbase Kit

 

 

 

15

RAK204D15P

 

 

 

20

RAK204D20P

 

 

 

30

RAK204D30P*

 

 

 

*Not approved for use on 7000 BTU models.

Electrical subbases provide an enclosure for direct connection or enclosed receptacles. The subbase kit includes the power cord.

The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.

DIRECT CONNECTION

Order the following Kit for 230/208-volt direct connection as required:

Branch Circuit and

Power Supply

Power

Unit Amperage Rating

Accessory

Supply Kit

 

 

 

 

15

RAK4002A

RAK4157

 

 

 

 

20

RAK4002A

RAK4207

 

 

 

 

30

RAK4002A

RAK4307

 

 

 

 

Skip to the “MAKE ELECTRICAL CONNECTION TO THE UNIT” section.

13

Image 13
Contents Write the model and serial numbers here Model # Serial # Air ConditionersReplacing an existing unit? Care and CleaningConsumer Support Fan, Mode & Operation Control Safety InstructionsQuick Heat Recovery Care and Cleaning Troubleshooting TipsCare and Cleaning To Remove the Room Cabinet Other features of your ZonelineTroubleshooting Tips Consumer Support Air Direction Ventilation ControlAuxiliary Controls on your Zoneline Load Shedding Central Desk Control Temperature LimitingFreeze Sentinel Constant on FanGe.com Heat SentinelCentral Desk Control External Fan Obtained locallyCare and cleaning Troubleshooting Tips Consumer Support Air Filters Safety Operating InstructionsInstructions Tools YOU will Need Before YOU BeginZoneline Components Use the correct wall case Replacing AN Existing UNIT?Power Cord Connection 230/208 Volt Electrical Connection Options HOW to ConnectPower Direct ConnectionFor Direct Connect Installation For Subbase InstallationBranch Circuit Proper GE Power Branch Circuit PowerMake Electrical Connection to the Unit Power Cord Connections Power Connection ChartInstall the Wall Case Exterior Grille Installing the ZonelinePrepare the Unit Replace the Room Cabinet Install the Unit Into the Wall CaseExternal Drain OPTIONAL-DRAIN KIT InstallationZoneline does Before you call for service…Not start Or heat as it shouldAir is not always Temperature displayCool or hot during OperationNormal Operating Sounds Things that are normalCleaning Zoneline WarrantyGE Will Replace One YearParts and Accessories Schedule ServiceConsumer Support GE Appliances Website Real Life Design Studio
Related manuals
Manual 24 pages 46.19 Kb