Installation Instructions
265 VOLT ELECTRICAL CONNECTION OPTIONS
WARNING:
Connection of this 265 V AC product to a branch circuit MUST be done by direct connection in accordance with the National Electrical Code. Plugging this unit into a building mounted exposed receptacle is not permitted by code.
These models must be installed using the appropriate GE power supply kit for the branch circuit amperage and the electrical resistance heater wattage desired.
Use the POWER CONNECTION CHART on page 16 to determine the correct kit required. One of the following installation methods (A or B) must be used.
A. FOR SUBBASE INSTALLATION
Electrical subbase kits are available to provide a flexible enclosure for direct connection.
Branch Circuit and | Proper GE | Power | |
Unit Amperage Rating | Subbase Kit | Supply Kit | |
|
|
|
|
15 | RAK204E15 | RAK5172 | |
|
|
|
|
20 | RAK204E20 | RAK5202 | |
|
|
|
|
30 | RAK204E30 | RAK5302 | |
|
|
|
|
The instructions provided with the selected subbase kit must be carefully followed. It is the responsibility of the installer to ensure the connection of components is done in accordance with these instructions and all electrical codes.
B. FOR DIRECT CONNECT
INSTALLATION
If an electrical subbase is not used, direct connection to branch circuit wiring inside the provided junction box must be done in accordance with the following steps. Order the following Kit for
Branch Circuit and | Power | |
Unit Amperage Rating | Supply Kit | |
|
|
|
15 | RAK5157 | |
|
|
|
20 | RAK5207 | |
|
|
|
30 | RAK5307 | |
|
|
|
Proceed to the “MAKE ELECTRICAL CONNECTION TO THE UNIT” section.
NOTE: Order Kit RAK4002A to enable a quick disconnect inside the junction box.