Heath Zenith CB-2010 manual Installation, Wall Mount Eave Mount, Wire the Light Control

Page 2

Page 2

INSTALLATION

For easy installation, select an existing light with a wall switch for replacement.

Wall Mount

Eave Mount

For under eave installation, the sensor head must

be rotated as shown in the next two steps for proper operation and to avoid the risk 23456789012345678of electrical shock.

For eave mount only:

Swing the sensor head towards the clamp screw

joint.Controls Clamp screw

Then rotate the sensor head clockwise 180° so the controls face down.

Controls

Controls

If the sensor pops out of the ball joint, loosen the clamp screw and push the sensor back into the ball joint. Tighten the clamp screw when done.

WIRE THE LIGHT CONTROL.

Turn power off at the fuse or circuit breaker.

Remove the existing light fixture.

Install the mounting strap as shown using two screws that fit your junction box.

The plastic hanger can be used to hold the fixture while wiring. The small end of the plastic hanger can be threaded through the hole in the center of the cover plate. The small end then goes into one of the slots on the mounting strap.

Route the Light Control’s wires through the large gasket hole.

Twist the junction box wires and fixture wires together as shown. Secure with wire connectors.

 

 

 

White to

Mounting

Black to

 

Strap

Black

 

White

 

 

 

 

Rubber

Plug

Mounting

Bolt

Gasket

Junction box ground wire to green ground screw on fixture.

MOUNT THE LIGHT CONTROL.

Align the Light Control cover plate and cover plate gasket. Secure with the mounting bolt.

Push the Rubber Plug firmly into place.

If a wet location junction box was not used, caulk the wall plate mounting surface with silicone weather sealant.

To avoid water damage and electrical shock, keep lamp holders below horizontal.

 

 

Keep lamps at least

 

 

1" (2.5 cm) from the

 

 

sensor. Do not al-

Lock nut

Lens

low the lamps to

 

block the lens.

 

 

Adjust the lamp holders by loosening the lock nuts but do not rotate the lamp holders more than 180° from the factory setting. When screwing in the floodlamps, do not overtighten.

Image 2
Contents Model CB-2010 FeaturesOperation RequirementsWall Mount Eave Mount InstallationWire the Light Control Mount the Light ControlTurn on the circuit breaker and light switch Test and AdjustmentSpecifications Aim Sensor Down for Short Coverage Higher for LongSymptom Possible Cause Troubleshooting GuideYour HEATH/ZENITH 15 Year Limited Warranty Características FuncionamientoModelo CB-2010 RequisitosApague la energía en el fusible o cortacircuitos InstalacionConecte EL Control DE LUZ Instale EL Control DE LUZPrueba Y Ajuste EspecificacionesSintoma Posible Causa Si tiene problemas con su Control de Luz consulte esta guíaGuia DE Investigacion DE Averias Caractéristiques FonctionnementModèle CB-2010 ExigencesMontage mural Montage sous avant-toit Câblage de la Commande D’ÉclairageMontage de la Commande D’Éclairage Enlever l’appareil d’éclairage existantBas du détecteur Éviter de pointer l’appareil Essais ET RéglagesFiche Technique 21 m 30,5 mGuide DE Dépannage Symptôme Cause Possible