Heath Zenith CB-2010 manual Test and Adjustment, Specifications, Avoid aiming the sensor at

Page 3

Page 3

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 12 minute warm up period before it will detect motion. When first turned on or when switching modes wait 12 minutes.

Turn the RANGE control to the mid position and the ON-TIME control to the TEST position.

Loosen the clamp screw in the sensor ball joint and gen- tly rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on. Move the sensor head up, down, or sideways to change the cov- erage area. Keep the sensor at least 1" (2.5 cm) away from the lamps.

Adjust the RANGE as needed. RANGE set too high may increase false triggering.

Secure the sensor head's aim by tightening the clamp screw. Do not overtighten the screw.

Clamp

Screw

Ball

Joint

Aim Sensor

Down for Short

Coverage

Aim Sensor

Higher for Long

Coverage

Bottom of Sensor

Avoid aiming the sensor at:

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5 or 20 minutes).

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the con- trol.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

200°

8ft.

(2.4 m)

70 ft.

100 ft.

 

(21 m)

(30.5 m)

 

 

Boosted

 

Maximum Range

Maximum

Coverage Angle

The detector is less sensitive to motion directly towards it.

MotionMotion

SPECIFICATIONS

Range . . . . . . . . . . . . Up to 70 ft. (21 m); 100 ft. (30.5 m) with Range Boost. [varies with surrounding temperature]

Sensing Angle . . . . . . Up to 200°

Electrical Load . . . . . . 300 watt Incandescent [150 W each lamp holder].

Power Requirements . 120 VAC, 60 Hz

Operating Modes . . . . TEST, AUTO and MANUAL

MODE

Time Delay . . . . . . . . 1 , 5, 20 minutes

Heath/Zenith reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

Least Sensitive

Sensor

Most Sensitive

 

Image 3
Contents Requirements FeaturesOperation Model CB-2010Mount the Light Control InstallationWire the Light Control Wall Mount Eave MountAim Sensor Down for Short Coverage Higher for Long Test and AdjustmentSpecifications Turn on the circuit breaker and light switchTroubleshooting Guide Your HEATH/ZENITH 15 Year Limited WarrantySymptom Possible Cause Requisitos FuncionamientoModelo CB-2010 CaracterísticasInstale EL Control DE LUZ InstalacionConecte EL Control DE LUZ Apague la energía en el fusible o cortacircuitosEspecificaciones Prueba Y AjusteSi tiene problemas con su Control de Luz consulte esta guía Guia DE Investigacion DE AveriasSintoma Posible Causa Exigences FonctionnementModèle CB-2010 CaractéristiquesEnlever l’appareil d’éclairage existant Câblage de la Commande D’ÉclairageMontage de la Commande D’Éclairage Montage mural Montage sous avant-toit21 m 30,5 m Essais ET RéglagesFiche Technique Bas du détecteur Éviter de pointer l’appareilSymptôme Cause Possible Guide DE Dépannage