Heath Zenith 7001 manual Battery Replacement, Specifications

Page 3

BATTERY REPLACEMENT

This solar light contains a rechargeable battery that can be replaced if needed. To replace the battery follow the steps below.

IMPORTANT: The sealed lead-acid battery must be recycled or disposed of properly.

1.Remove rear battery cover. Press in the two catch releases on the cover and remove the cover.

2.Remove rechargeable battery.Slide battery out of case and remove the wire connectors from the battery.

3.Replace battery. Connect the RED wire connector to the positive (+) terminal and the BLACK wire connector to the negative (-) terminal.

4.Replace battery cover.Insert the two tabs on the cover into the slots on the back of the case. Press the cover against the case until the two catch releases snap into place.

IMPORTANT: Keep sensor switch in the “OFF” position for three days to allow the battery to fully charge before testing.

Tab Slots

Positive Wire

Rechargeable

Battery

Battery

Cover

SPECIFICATIONS

Range

Up to 70 ft. (21 m); [varies with

 

surrounding temperature]

Sensing Angle

Up to 180°

Lamp

15 watt, 6 volt halogen

Battery Type

Sealed lead acid, 6 V 6.0 A-Hr.

On Time

1 or 5 minutes, re-triggerable

Full Charge on Time

Up to 1 hour

IMPORTANT:Replace lamp only with same type lamp, 20 watts or less. DO NOT reverse the battery wires. Damage to the unit will result. Like any lead-acid battery, this battery must be disposed of properly.

HeathCo LLC reserves the right to discontinue products and to change specifications at any time without incurring any obligation to incorporate new features in products previously sold.

Negative Wire

Battery Cover Catch Release

598-1305-02

Image 3
Contents Requirements FeaturesInstallation ModelThings To Remember Test and AdjustmentAdjustment of Coverage Area OperationSpecifications Battery ReplacementSymptom Possible Cause Solution Troubleshooting GuideTechnical Service No Service Parts Available for this ProductDesempaque ModeloCaracterísticas RequisitosPrueba Y Ajuste Regulación del Área de CoberturaParte inferior del detector Especificaciones FuncionamientoPuntos Que Se Deben Recordar Cambio DE LA BateríaGuía DE Análisis DE Averías Servicio TécnicoSíntoma Posible Causa Solución Déballage ModèleCaractéristiques ExigencesLe bas pour réduire la Le haut pour augmenter Couverture Essai ET RéglageRéglage de la Zone de Couverture Desserrer la vis de blocage de la rotuleFiche Technique Remplacement DE LA PileFonctionnement RappelGarantie Limitée DE 5 ANS Service TechniqueSymptôme Cause Possible Solution Guide DE Dépannage