3.INSTALLATION (CONT’D)

3.9INSTALLING 2 EXTERIOR HOODS

Choose an appropriate location to install the exterior hoods:

There must be a minimum distance of 6 feet (1.8 m) between the hoods to avoid cross-contamination

There must be a minimum distance of 18 inches (457 mm) from the ground

Make sure the intake hood is at least 6 feet (1.8 m) away from the following:

Dryer exhaust, high efficiency furnace vent, central vacuum vent

Gas meter exhaust, gas barbecue grill

Any exhaust from a combustion source

Garbage bin and any other sources of contamination

Refer to figure below for connecting insulated ducts to the exterior hoods. An ‘’Anti-gust intake hood’’ should be installed in regions where a lot of snow is expected to fall.

 

6’’ Ø

EXHAUST HOOD

(152 MM)

INTAKE HOOD

18’’

(457 MM)

6’

18’’

(1.8 M)

(457 MM)

6’

(1.8 M)

18’’

OPTIONAL(457 MM)

DUCT LOCATION

TAPE AND DUCT TIE

VD0028

- 16 -

Image 16
Contents Installation Instructions HRV90H and ERV90HC About this Manual About These Units LimitationTable of Contents Technical Data HRV ERVTechnical Data CONT’D Ventilation PerformanceHRV Typical Installations Typical Installations CONT’D Installation Installation CONT’D Make sure the unit is levelStale air exhaust ductwork Fresh air distribution ductworkDuct, see figure beside Method 1 Supply side connectionMethod 2 Return side connection Stale air intake Fresh air distributionRigid ducts Insulated flexible ductsDo not use screws to connect the rigid ducts to the ports 457 mm Xmas tree pin ’’ Ø Controls AvertissementControls CONT’D No C NC I OC OL Y R G BElectrical Connection to the Furnace OC OL Y R G6WIRINGDIAGRAM Balancing the Unit Connecting the Drain HRV Units only To drainMaintenance Maintenance CONT’D Service Parts HRV90HS HRV90HT ERV90HCS ERV90HCTTroubleshooting Problems Possible causes You should try thisManual DE Instalación Modelos HRV90H Y ERV90HC Acerca DE Este Manual Acerca DE Estos Aparatos LimitaciónAdvertancia CuidadoÍndice Datos Técnicos Temperatura exterior Ciclos DE Deshielo DEL HRV y ERVRendimiento de ventilación Datos Técnicos ContinuaciónDimensiones Instalaciones Habituales Sistema Totalmente EntubadoInstalaciones Habituales Continuación Instalación Tubos de extracción de aire viciado Compruebe que el aparato esté a nivelTubos de distribución del aire puro Método 1 Conexión por el lado de la alimentación Método 2 Conexión por el lado de retornoAdmisión de aire viciado Distribución del aire puroTubos flexibles aislados Tubos rígidosTubo de aire de salida hacia el exterior Pasador de Instalación DE 2 Bocas Exteriores Controles Control IntegradoControles Continuación Conexión Eléctrica CON LA Caldera No C NCDiagrama DE Cableados Diagrama DE Cableados Diagrama LógicoEquilibrado DEL Aparato Ponga el aparato en velocidad altaConexión DEL Desagüe Aparatos HRV Únicamente Al desagüeMantenimiento Mantenimiento Continuación Piezas Solución DE Problemas Problemas Causas posibles Debería hacer esto
Related manuals
Manual 54 pages 23.2 Kb

ERV90HCT specifications

The Broan ERV90HCT and HRV90HT are remarkable energy recovery ventilators designed to enhance indoor air quality while promoting energy efficiency in residential settings. Both models are built with innovative technologies that meet the demands of modern homes, ensuring a comfortable living environment.

One of the standout features of the Broan ERV90HCT and HRV90HT is their energy recovery capabilities. They efficiently exchange stale indoor air with fresh outdoor air, recovering up to 90% of the energy that would otherwise be lost. This process not only improves air quality but also helps in reducing heating and cooling costs, making them an excellent investment for energy-conscious homeowners.

Another significant characteristic of both models is their quiet operation. Equipped with advanced fan technology, the ERV90HCT and HRV90HT work at minimal noise levels, ensuring a peaceful indoor atmosphere. Whether in a bedroom, living room, or office, occupants can enjoy the benefits of fresh air without disruptive noise.

The units are designed with user-friendly controls that make operation simple and intuitive. Homeowners can easily adjust settings to optimize airflow based on current needs, whether it’s high ventilation during peak usage times or lower settings for quieter moments. Additionally, the units come with a built-in timer, allowing for customizable operation schedules.

Durability is another hallmark of the Broan ERV90HCT and HRV90HT. Constructed with high-quality materials, these ventilators are designed for long-lasting performance. Furthermore, their compact design allows for flexible installation options, making them suitable for various home layouts and sizes.

The ERV90HCT features a heat recovery system, making it ideal for climates that experience significant temperature fluctuations, while the HRV90HT is tailored for those residing in colder regions. Both units utilize an efficient balanced ventilation system, ensuring that airflow is evenly distributed throughout the home.

In summary, the Broan ERV90HCT and HRV90HT are top-tier energy recovery ventilators that prioritize comfort, efficiency, and air quality. With their energy recovery capabilities, quiet operation, user-friendly controls, durability, and flexible installation options, they stand out in the market as excellent solutions for maintaining a healthy home environment. Whether seeking to reduce energy costs or improve indoor air quality, these models deliver on all fronts, making them a worthy addition to any household.