Atlas MLGC180B, MLGC180W manual Test and Adjustment, Bottom of Sensor, Avoid aiming the control at

Page 4
Clamp Screw
Ball Joint
Aim Sensor
Down for Short
Coverage
Aim Sensor
Higher for Long
Coverage

TEST AND ADJUSTMENT

Turn on the circuit breaker and light switch.

NOTE: Sensor has a 1 1/2 minute warm up period before it will detect motion. When first turned on, wait 1 1/2 minutes.

NOTE: Meets the ENERGY STAR® guidelines when used with 120 W Max bulbs.

Turn the RANGE control to the medium position (halfway between MIN and MAX) and the ON-TIME control to the TEST position.

ON-TIMERANGE

10 5 1 TEST

MIN MAX

Bottom of Sensor

Avoid aiming the control at:

Objects that change temperature rapidly, such as heating vents and air conditioners. These heat sources could cause false triggering.

Areas where pets or traffic may trigger the control.

Nearby large, light-colored objects reflecting light may trigger the shut-off feature. Do not point other lights at the sensor.

NOTE: If fixture is mounted higher than 8 ft.(2.4 m), aiming the sensor down will reduce coverage distance.

The detector is less sensitive to motion directly towards it.

MotionMotion

 

Sensor

Least Sensitive

Most Sensitive

Loosen the clamp screw in the sensor ball joint and gently rotate the sensor.

Walk through the coverage area noting where you are when the lights turn on (also, the LED will flash several times when motion is detected).Move the sensor head up, down, or sideways to change the cover- age area. Keep the sensor at least 1" (25 mm) away from the bulbs.

Adjust the RANGE as needed.

RANGE set too high may increase false triggering.

Secure the sensor head by tightening the clamp screw.

Do not overtighten the screw.

Set the amount of TIME you want the lights to stay on after motion is detected (1, 5, or 10 minutes).

8 ft.

180°

 

(2.4 m)

 

70 ft.

 

(21 m)

 

Maximum Range

Maximum

 

Coverage Angle

WARNING: Risk of fire. Do not aim the bulbs at a combustible surface within 3 ft. (1 m).

598-1098-02

Image 4
Contents Operation Features Requirements Installation Mode Switching SummaryWall Mount Eave MountJunction box ground wire to green ground screw on fixture Mounting Black to White to StrapTest and Adjustment Turn on the circuit breaker and light switchBottom of Sensor Avoid aiming the control atSpecifications Troubleshooting GuideFive Year Limited Warranty 598-1098-02 598-1098-02