Pelco pmp-cwv9r manual Removal, DIP Switch Settings

Page 7

Removal

1. Place the monitor face down, being careful not to scratch or touch the screen.

NOTE: Disconnect the monitor from the power source before removing and replacing the camera. 2. Use the thumbscrew on the bottom of the monitor to open the access door, refer to Figure 2.

Figure 2. Access Door

3.Unscrew the three metric screws (14 mm) that secure the camera. Remove the screws and spacers.

4.Gently pull the camera out of the monitor, being careful not to damage the attached connection leads. Detach the two camera connection leads from the camera

DIP Switch Settings

Set the DIP switches on the replacement camera before installing it in the PVM.

1.Locate the DIP switch.

2.Set the switches for your installation using a small screwdriver, refer to Figure 3.

Figure 3. DIP Switches

C2948M (5/08)

7

Image 7
Contents PMP-CWV9R C2948M 5/08 List of Illustrations ContentsImportant Safety Instructions Radio and Television Interference Regulatory NoticesDescription Package ContentsRemoval DIP Switch SettingsSW1-1 Video Format SW1-2 Line Sync Camera Installation and Camera Adjustment Models SpecificationsProduct Warranty and Return Information ISO9001